Search

In Stock

Mini Carbon Monoxide Meter

Ultra-Compact Portability: Designed to fit in a shirt pocket or clip onto a belt, ensuring that personal safety monitoring is always within reach during inspections or maintenance tasks.

High-Stability Electrochemical Sensor: Utilizes a specialized electrochemical cell that offers superior selectivity for CO, minimizing false alarms from other gases while providing a rapid response time.

₹1,230.00

Quick Answer: The Mini Carbon Monoxide Meter is a pocket-size electronic gas detector that shows the concentration of carbon monoxide (CO) in the surrounding air, usually in parts per million. A handheld carbon monoxide meter is used for spot checks near fuel-burning equipment, where CO can build up with no smell or colour to give it away.

Detecting a Gas You Cannot Sense

Carbon monoxide forms when fuel burns without enough oxygen: a Bunsen burner with a yellow flame, a blocked flue, a charcoal stove indoors or a generator in a closed room. It has no colour, taste or smell and binds to haemoglobin far more strongly than oxygen does, so people can be affected before they notice anything. A meter makes the invisible measurable.

Compact CO meters commonly use an electrochemical sensor, in which carbon monoxide reacts at an electrode and produces a current in proportion to its concentration. The sensor ages and responds more slowly over the years, and it can react slightly to some other gases, so readings are for screening rather than formal exposure records. Switch the meter on in clean outdoor air so it starts from a true zero, then carry it into the area to be checked.

A handheld unit tells you what the air is like where you are standing, at that moment. It does not replace a fixed CO alarm in bedrooms, boiler rooms or labs with gas appliances, which watches continuously. For carbon dioxide, a different gas with different risks, see the carbon dioxide meter.

Specifications

Type Handheld (mini) carbon monoxide meter
Measures CO concentration in ambient air, typically in ppm
Sensor Electrochemical type is usual in compact CO meters
Use mode Spot checks by an operator; not a fixed alarm
Where used Labs with gas burners, kitchens, boiler rooms, garages, generator areas
Range, alarm levels and sensor life Confirm at enquiry

Applications

  • Checking chemistry-lab air during practicals that run many gas burners in a small room
  • Inspecting boiler rooms, hostel kitchens and canteens for flue or ventilation faults
  • Showing, in a fume cupboard under teacher supervision, that a yellow luminous flame releases more CO than a roaring blue one
  • Screening garages, workshops and generator rooms before staff start work there

Care & Handling

  • Start the carbon monoxide meter in fresh air, away from engines and burners, so it zeroes correctly.
  • Keep the sensor opening free of dust, solvent vapour and water; strong solvents can damage electrochemical sensors.
  • Test the alarm function regularly, and replace the unit or its sensor when response becomes sluggish or it fails a check with test gas.
  • If the meter alarms, leave the area, ventilate it and have the source examined; do not stay to watch the number.

Why Choose LabEquip

School and college labs with a gas supply, hostel kitchens and maintenance teams buy a pocket CO meter for quick checks. LabEquip lists it under General Lab Products; ask about the sensor type and alarm settings through the contact page.

Frequently Asked Questions

Can this meter replace a carbon monoxide alarm?

No. A handheld meter reads only when someone carries it and switches it on. Rooms with gas appliances or fuel-burning heaters also need a fixed alarm that monitors continuously, including at night.

Why must it be switched on in fresh air?

Many compact meters set their zero at start-up. If they start in air that already contains CO, that concentration is treated as zero and later readings come out too low.

What does a yellow Bunsen flame have to do with carbon monoxide?

A yellow, smoky flame shows that air is limited and combustion is incomplete, which produces more carbon monoxide than a blue flame with the air hole open. Keeping burners adjusted and rooms ventilated reduces CO.

Can it detect other gases such as LPG or carbon dioxide?

No. It is designed for carbon monoxide. LPG leaks need a combustible-gas detector, and carbon dioxide needs a separate CO2 meter. Some CO sensors react weakly to other gases, which can cause small false readings.

How long does the sensor last?

Electrochemical sensors wear out gradually, so their life depends on the model and on exposure. A sensor that responds slowly or fails a test with calibration gas should be replaced, or the meter serviced.

What should I do if the reading rises?

Treat any rising reading as a warning: switch off fuel-burning equipment if it is safe to do so, open windows, move everyone out and have the appliance or flue inspected. Anyone with headache, dizziness or nausea should get fresh air and medical advice.

Last Updated: September 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
INR Indian rupee
Product has been added to your cart
Compare (0)