Search

In Stock

Vacuum Plate with 2 Valves and Electrical Passage

Platine à vide à 2 robinets avec passage électrique, Integrated Electrical Feedthrough Facilitates student Evaluation of electrical discharge behavior and electromagnetic properties within a vacuum, supporting advanced physics modules.

High-Vacuum Gasket Interface Ensures systemic stability for long-duration experiments, allowing students to apply mathematical pressure-volume models with minimal measurement error.

Ruggedized Metal Platform provides a durable, vibration-resistant foundation that supports the Synthesis of complex vacuum assemblies involving bell jars and internal transducers.

$20.36

Quick Answer: The vacuum plate with 2 valves and an electrical feedthrough is a base plate for bell jar experiments: one valve is normally used for the pump line and the other to let air back in or attach a gauge, while the feedthrough carries wires through the plate so that devices inside the evacuated jar can be powered or monitored.

Why Two Valves Help

A single-valve plate must be disconnected from the pump, or the pump vented, to let air back in. With two valves the jobs can be separated: one valve connects the pump line and can be closed to hold the vacuum once pumping stops, while the second admits air in a controlled way at the end of the experiment, or connects a gauge or a second vessel. Closing the pump valve before switching off also stops air, or oil from an oil-sealed pump, being drawn back into the jar.

Controlled venting matters. Letting air rush in through a wide opening can knock over apparatus inside the jar, burst a fragile object or blow light materials around, whereas opening a dedicated vent valve gradually brings the jar back to atmospheric pressure smoothly.

Specifications

Item Vacuum base plate for bell jar experiments
Valves Two, as listed in the product name
Electrical feedthrough Sealed route for wires into the evacuated jar
Use With a bell jar and a hand or electric vacuum pump
Plate size, connector type and feedthrough rating Confirm at enquiry

Powering Experiments Inside the Jar

The electrical feedthrough is a sealed connection that carries conductors through the plate without letting air leak in. It allows a buzzer, lamp or small motor inside the jar to be switched from outside during the experiment, and sensor leads can be brought out in the same way. With the vacuum plate with 2 valves, students can, for example, compare how long a small fan keeps turning after switch-off at several pressures, a direct look at air resistance, without opening the jar.

Care & Handling

  • Use only low safety voltages through the feedthrough, within its rating
  • Keep the plate surface flat, clean and free of scratches where the jar seals
  • Close the pump valve before switching off the pump
  • Check that the feedthrough connections are tight and insulated before each use

Applications

  • Switching a bell or buzzer inside an evacuated jar
  • Studying air resistance with a small fan under reduced pressure
  • Bringing out sensor leads for pressure or temperature measurements
  • Controlled venting at the end of vacuum demonstrations

Why Choose LabEquip

Physics departments that run bell jar demonstrations regularly choose this plate because two valves and a feedthrough remove the usual workarounds of trailing wires and abrupt venting. It works with the vacuum pump 10 L/min and with demonstrations such as the bell in bell jar experiment; see more physics lab equipment and contact LabEquip for plate size and connectors.

Frequently Asked Questions

What is an electrical feedthrough?

It is a sealed electrical connection that passes through the wall of a vacuum vessel. Wires on the inside connect to apparatus in the jar and terminals on the outside connect to a supply or meter, while the seal keeps air out.

Why not just run the wires under the rim of the jar?

Wires trapped under the rim stop the jar sealing properly, so air leaks in and the pressure cannot be held. A feedthrough keeps the rim seal unbroken.

What voltage can be used through the feedthrough?

Keep to low safety voltages from a bench supply or batteries, within the rating given for the plate. Mains voltage should never be taken into a bell jar experiment.

Why should the pump valve be closed before the pump is switched off?

When a pump stops, air can leak back through it into the jar, and with an oil-sealed pump oil can be drawn back as well. Closing the valve first isolates the jar and keeps the vacuum.

How fast should the jar be vented?

Slowly. Opening the vent valve a little at a time lets the pressure rise smoothly, which protects light and fragile items inside and avoids a sudden jolt to the jar.

Which jars fit the plate?

A bell jar with a flat, ground or gasketed rim that sits fully on the plate surface can be used. The rim must be smaller than the plate and clear of the valve and feedthrough openings, so check the sizes when you enquire.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
USD United States (US) dollar
Product has been added to your cart
Compare (0)