Quick Answer: This study of thermal conductivity apparatus lets students measure how readily heat flows through solid samples by holding one end warm and the other cool and recording temperatures along the heat path. It is used in heat-transfer practicals to compare materials and to apply Fourier’s law of conduction.
From Temperature Gradient to Conductivity
Heat conduction through a solid follows Fourier’s law: the rate of heat flow through a sample equals k A (T1 – T2) / L, where A is the cross-sectional area, L the distance between two temperature points and k the thermal conductivity of the material. In this kind of study one end of the sample is kept warm and the other cool, and once the temperatures stop changing the flow has reached steady state, with every section passing on the same amount of heat each second.
Reading the temperature at several points along the sample shows the gradient directly. A good conductor such as copper carries the heat with only a gentle temperature drop, while a poorer conductor needs a much steeper drop to pass the same heat. Plotting temperature against position turns this into a straight-line graph whose slope students can compare from one sample to the next.
Specifications
| Experiment | Thermal conductivity of solid samples by steady-state heat flow |
| Governing law | Fourier’s law of heat conduction |
| Quantities recorded | Temperatures along the heat path, plus the heating power or heat removed |
| Typical analysis | Temperature-position graph and comparison of materials |
| Samples, heater and sensors supplied | Confirm at enquiry |
Planning a Reliable Measurement
The key judgement in a thermal conductivity study is when to read. Temperatures rise quickly at first and then level off, so logging them every minute or two and waiting until successive readings agree avoids recording a transient state. Heat escaping from the sides of the sample makes the gradient curve instead of staying straight, which is why insulation around the sample and tidy sensor connections matter.
To turn the gradient into a value for k, the rate of heat flow must also be known, either from the electrical power fed to a heater or from the temperature rise of cooling water that carries the heat away. Where only a comparison is needed, the ratio of gradients for two samples carrying the same heat flow gives the ratio of their conductivities directly.
Practical Uses
- Applying Fourier’s law in a heat-transfer practical
- Comparing the conductivity of metals of different composition
- Showing the approach to steady state with a temperature-time record
- Linking conductivity to the choice of materials for heat sinks and insulation
Care & Handling
- Allow the heated end to cool before changing or handling samples
- Keep contact faces clean so heat passes evenly between the sample and the heater or cold block
- Store temperature sensors with their leads loosely coiled to avoid breaking the wires
- Record the room temperature with each run, as draughts change the side losses
Why Choose LabEquip
Physics departments order this apparatus for practicals where students need numbers rather than a quick demonstration. For the classic lagged-bar method at undergraduate level it pairs with Searle’s thermal conductivity apparatus, and the wider range sits under physics lab equipment; contact LabEquip to confirm which samples and sensors are included.
Frequently Asked Questions
What does steady state mean in a conductivity experiment?
It is the point at which the temperature at every position along the sample stops changing. Heat is still flowing, but each part passes on as much heat as it receives, so the temperature gradient can be used in Fourier’s law.
Why must the cross-sectional area and length of each sample be known?
Conductivity relates heat flow to the temperature gradient per unit area. A thicker sample carries more heat for the same gradient, so without the area and the distance between sensors the results for different samples cannot be compared fairly.
Why does the temperature graph sometimes curve instead of staying straight?
Heat leaking from the sides means less heat reaches the far end, so the gradient becomes shallower along the sample. Better insulation, a lower heater setting or shorter measuring distances bring the graph closer to a straight line.
Can poor conductors such as plastics be tested the same way?
Poor conductors need a much larger temperature difference to pass measurable heat, so long bars are impractical for them. They are normally tested as thin discs pressed between a hot and a cold plate, as in Lees’ disc method.
How is the heat flow rate found?
It can be taken from the electrical power supplied to a heater, allowing for losses, or from the flow and temperature rise of cooling water at the cold end. For a simple comparison between samples it need not be measured, provided both samples carry the same heat flow.
Which temperature sensors are suitable?
Thermocouples, thermistor probes or digital thermometers can all be used if they are checked against each other before the run. Small offsets between sensors matter because the temperature differences being measured are often only a few degrees.
Last Updated: October 2026