Quick Answer: Searle’s thermal conductivity apparatus measures the thermal conductivity of a good conductor, usually a copper bar, by heating one end with steam and cooling the other with flowing water. The bar is lagged so that, at steady state, the heat entering the water each second equals the heat conducted along the bar.
How Searle’s Bar Method Works
In Searle’s method a thick metal bar is enclosed in lagging, typically felt or wool, so that almost no heat escapes from its sides. One end sits inside a steam chest; the other end carries a coil through which cold water circulates. Heat therefore flows along the bar in one direction only, from the steam end to the water-cooled end.
Two thermometers sit in holes drilled into the bar a known distance apart, and two more record the temperature of the water entering and leaving the coil. Once every reading has stopped changing, the bar is in a steady state. The heat carried away by the water per second follows from the mass of water collected in a timed interval, its specific heat capacity and its temperature rise. The thermal conductivity is then that heat flow multiplied by the distance between the bar thermometers, divided by the bar’s cross-sectional area and by the temperature difference between those two points.
The method suits good conductors because a metal bar can be made long and thick enough to give a measurable temperature difference along it while still passing plenty of heat. A poor conductor would pass so little heat that the water temperature would hardly change, which is why insulators are tested by a disc method instead.
Getting Reliable Readings
Steady flow of cooling water matters more than a fast flow. Many laboratories feed the coil from a constant level tank so that the rate does not drift as the main supply pressure changes. The rise in water temperature should be large enough to read accurately, so the flow is adjusted until the outlet is several degrees warmer than the inlet. Reaching steady state can take a long time, and readings taken before all four thermometers settle give a falsely high or low result.
Specifications
| Method | Searle’s bar method for good conductors |
| Specimen | Lagged metal bar, usually copper |
| Hot end | Steam chest fed from a steam generator |
| Cold end | Coil with circulating water |
| Thermometers | Four positions: two in the bar, water inlet and water outlet |
| Thermometers and steam generator supplied | Confirm at enquiry |
Applications
- Determining the thermal conductivity of copper or another good conductor in undergraduate heat practicals
- Demonstrating steady-state heat flow and temperature gradient along a lagged bar
- Practising calorimetry with a continuous flow of water
- Comparing results with the disc method used for poor conductors
Care & Handling
- Drain and dry the steam chest after use to prevent corrosion inside it.
- Keep the lagging dry and intact; damp or torn lagging lets heat escape from the sides of the bar.
- Insert the thermometers gently into their holes; a few drops of oil in each hole, where the practical sheet allows it, improve thermal contact.
- Let the bar cool before handling it, as the steam end stays hot long after the steam is turned off.
Why Choose LabEquip
College physics departments buy Searle’s thermal conductivity apparatus for the good-conductor experiment and usually pair it with Lee’s and Charlton’s apparatus for insulators. LabEquip lists it with its wider physics lab equipment, and our team can advise on the accessories you need through the contact page.
Frequently Asked Questions
Which materials can be tested with Searle’s apparatus?
It is designed for good conductors of heat, mainly metals such as copper or brass made into a bar. Poor conductors such as glass or cardboard pass too little heat and are tested with a disc method like Lee’s and Charlton’s apparatus.
Why is the bar lagged?
Lagging stops heat escaping from the sides, so the heat conducted past the two bar thermometers is the same heat that reaches the water. Without it, the calculation would overestimate the heat flow and give a wrong conductivity.
How do I know the apparatus has reached steady state?
Read all four thermometers every few minutes. Steady state is reached when none of them changes over several consecutive readings, which often takes a considerable time after the steam is first passed.
Why use a constant level tank for the cooling water?
The calculation assumes a constant rate of water flow. A constant level tank keeps the pressure head fixed, so the flow does not vary as the mains pressure changes during the experiment.
What measurements are needed besides temperatures?
You need the distance between the bar thermometers, the diameter of the bar to find its cross-sectional area, and the mass of water collected in a measured time, together with the specific heat capacity of water.
Is this apparatus suitable for school classes?
It is mainly used at senior secondary and undergraduate level because the experiment is long and needs steam. For a quick qualitative comparison of conductors in junior classes, a simpler heat conductivity apparatus is more practical.
Last Updated: October 2026