Quick Answer: The e/m by Magnetic Focusing Method apparatus determines the specific charge of the electron (charge divided by mass) by sending an electron beam along the axis of a solenoid and adjusting the axial magnetic field until a spread beam refocuses to a spot. The magnetic focusing method is a standard practical in undergraduate physics laboratories.
Principle: Electrons Moving in Helices
In this experiment a cathode ray tube sits inside a long solenoid, with the beam travelling along the solenoid’s axis. Electrons are accelerated through a known voltage V, so they all leave the gun with the same forward speed. A small alternating voltage on one pair of deflection plates gives each electron a slightly different sideways velocity, and on its own this smears the spot into a line on the screen.
When current flows in the solenoid, the axial magnetic field B does not change the forward speed but bends the sideways motion into a circle, so each electron follows a helix. Every electron takes the same time, 2πm/(eB), to complete one turn of its helix, whatever its sideways speed. If the field is adjusted so that this time equals the time taken to travel from the deflection plates to the screen, all the electrons arrive back on the axis together and the line shrinks to a sharp spot. Equating the two times gives e/m = 8π²V/(B²L²), where L is the distance from the deflection plates to the screen and B is found from the solenoid current, its turns per metre and the permeability of free space.
Taking the Readings
The accelerating voltage is set and recorded, then the solenoid current is raised slowly from zero while the screen is watched. The line rotates and shortens, and the current at which it first collapses to a point is noted. Reversing the solenoid current and repeating, then averaging, reduces the effect of the Earth’s field and any stray fields; aligning the solenoid axis east-west helps further. Repeating at several accelerating voltages and plotting B² against V gives a straight line whose slope yields e/m from all the readings at once.
Specifications
| Quantity determined | Specific charge e/m of the electron |
| Method | Magnetic focusing of an electron beam in an axial field (Busch method) |
| Main parts (typical) | Cathode ray tube, solenoid, tube power supply, DC supply and ammeter for the solenoid |
| Level | Undergraduate and engineering physics laboratories |
| Tube type, supplied parts and supplies | Confirm at enquiry |
Care & Handling
- The cathode ray tube needs a high accelerating voltage; switch off before changing any connection and keep covers in place while the supply is on.
- Raise the solenoid current gradually and switch it off between readings so the winding does not overheat.
- Allow the tube heater to warm up and the beam to stabilise before taking readings.
- Keep magnets, steel stands and other magnetic materials away from the tube during measurements.
Where It Is Used
- Determining e/m of the electron in BSc and engineering physics practical courses
- Demonstrating helical motion of charged particles in a magnetic field
- Comparing the result with values from other methods, such as the Thomson bar magnet method
- Discussing focusing by magnetic fields, the principle behind magnetic lenses in electron microscopes
Why Choose LabEquip
University and college physics departments buy this apparatus for their modern-physics practical benches, often alongside other e/m methods so students can compare techniques. LabEquip lists it in its physics lab equipment range, together with the short solenoid magnetron method set-up. For tube type and supply details, contact us through the LabEquip contact page.
Frequently Asked Questions
What is the principle of the magnetic focusing method?
Electrons in an axial magnetic field move in helices, and all of them take the same time to complete one turn. When that time equals their travel time to the screen, a spread beam refocuses to a spot, and the field needed for this gives e/m.
Why is an alternating voltage applied to the deflection plates?
It gives the electrons a range of sideways velocities, spreading the spot into a line. Watching the line collapse back to a point is a clear, easily judged sign that the focusing condition has been reached.
What formula gives e/m in this method?
For the first focus, e/m equals 8 times pi squared times V, divided by B squared times L squared. V is the accelerating voltage, L the distance from the deflection plates to the screen, and B the axial field from the solenoid.
Why should the solenoid current be reversed during the experiment?
Reversing the current reverses the solenoid field while the Earth’s field and stray fields stay the same. Averaging the readings for both directions cancels much of their effect on the result.
How does this method differ from Thomson’s method?
Thomson’s method balances an electric deflection against a magnetic deflection. The magnetic focusing method uses only a magnetic field and a focusing condition, which avoids measuring a small deflection on the screen.
What safety precautions apply?
The tube supply uses a high voltage, so connections are made with the supply off and covers kept in place. The solenoid should not carry current for longer than needed, and the experiment is done under supervision.