Pregnant with Environmental Testing CTC

$961.09

The StemAids CTC Environmental Testing Chamber is a professional climatic test chamber designed for controlled temperature and humidity testing of materials, components, products, and laboratory samples. It is suitable for ageing tests, climate simulation, stability testing, material testing, electronics testing, automotive component testing, packaging validation, quality control, and research laboratory applications.

Product Description

The StemAids CTC Environmental Testing Chamber is designed to simulate controlled environmental conditions for testing how samples respond to heat, cold, and humidity exposure. It supports rapid temperature changes and humidity-controlled testing, making it useful for product durability studies, function testing, accelerated ageing, and environmental stress evaluation.

The CTC-type climatic chamber is especially suitable for laboratories that require repeatable test conditions for materials such as plastics, composites, concrete, packaging, electronic components, metal parts, coatings, and finished products. Its 256 litre chamber volume provides practical working space while maintaining compact floor placement.

Product Specifications

Parameter Details
Product Name CTC Environmental Testing Chamber
Brand StemAids
Reference Type CTC256 climatic / environmental test chamber type
Product Type Environmental test chamber / climatic test chamber with humidity control
Chamber Volume 256 litres
Temperature Range Without Humidity -42°C to +190°C
Temperature Range With Humidity +10°C to +95°C
Humidity Range 10% RH to 98% RH
Average Cooling Speed Approx. 3 K/min from +180°C to -40°C
Average Heating Speed Approx. 10 K/min from -40°C to +180°C
Interior Material Stainless steel interior
Interior Dimensions Approx. 640 × 670 × 597 mm, W × H × D
Exterior Dimensions Approx. 898 × 1730 × 1100 mm, W × H × D
Maximum Number of Internals 6
Maximum Loading Per Internal 25 kg
Installation Mounted on lockable castors
Defrosting Automatic evaporator defrosting system
Electrical Load Approx. 7000 W
Power Supply 400 V, 3-phase, 50 Hz, depending on supplied configuration
Control System Advanced climatic chamber control system with programmable test operation
Application Environmental testing, temperature cycling, humidity testing, ageing tests, material testing, and product validation
Suitable For Research labs, QC labs, electronics labs, automotive testing, aerospace testing, material testing, packaging labs, universities, and industrial laboratories

Key Features

  • Professional climatic test chamber for temperature and humidity simulation
  • Wide temperature range from -42°C to +190°C without humidity
  • Humidity-controlled testing from +10°C to +95°C
  • Humidity range from 10% RH to 98% RH
  • 256 litre chamber volume for medium-capacity environmental testing
  • Rapid heating and cooling performance for accelerated test cycles
  • Stainless steel interior for clean and durable laboratory use
  • Automatic evaporator defrosting for reliable long-term operation
  • Lockable castors for easy positioning and secure placement
  • Suitable for product ageing, material validation, electronics testing, and quality-control workflows

How to Use

  1. Place the StemAids CTC Environmental Testing Chamber on a clean, dry, level, and well-ventilated laboratory floor.
  2. Lock the castors after positioning the chamber in the required location.
  3. Connect the chamber to the correct electrical supply as mentioned on the rating plate.
  4. Switch on the chamber and allow the control system to initialise.
  5. Select the required test mode, such as temperature-only testing or temperature-humidity testing.
  6. Set the required temperature, humidity level, ramp rate, and test duration according to the test method.
  7. Allow the chamber to stabilise before loading samples.
  8. Place samples on shelves with sufficient spacing for air circulation.
  9. Do not overload shelves beyond the recommended load capacity.
  10. Close the chamber door properly before starting the test cycle.
  11. Monitor chamber readings during the test and record test conditions as required.
  12. After completion, allow samples to return to a safe handling temperature before removal.
  13. Clean the chamber interior and remove any residue after testing.

Applications

  • Environmental simulation testing
  • Temperature cycling tests
  • Humidity exposure tests
  • Accelerated ageing studies
  • Material durability testing
  • Electronics and PCB reliability testing
  • Automotive component testing
  • Aerospace material testing
  • Packaging and product validation
  • Plastic, composite, coating, and concrete testing
  • Research, quality-control, and educational laboratory testing

Safety and Handling Guidelines

  • Use the chamber only within the specified temperature and humidity range.
  • Do not test explosive, flammable, volatile, or corrosive materials unless the chamber is specifically rated for that use.
  • Maintain proper ventilation around the chamber for heat dissipation.
  • Do not block internal air circulation with oversized samples.
  • Use heat-resistant gloves when handling hot samples or shelves.
  • Use cold-protection gloves when removing samples after low-temperature testing.
  • Do not open the chamber door unnecessarily during an active test cycle.
  • Do not exceed the maximum load per internal shelf.
  • Keep the chamber clean and dry after humidity testing.
  • Allow only trained personnel to operate, clean, and maintain the chamber.
  • Disconnect power only according to safe shutdown procedure.
  • Maintain calibration, validation, and preventive maintenance records for regulated testing.

Quality and E-E-A-T Notes

The StemAids CTC Environmental Testing Chamber supports evidence-based testing by providing controlled temperature, humidity simulation, programmable environmental cycles, stable sample exposure, and repeatable test conditions. For regulated or critical testing, users should follow written SOPs, maintain calibration certificates, document test parameters, verify chamber uniformity, and record sample exposure history for traceability.

FAQ

1. What is the StemAids CTC Environmental Testing Chamber used for?

It is used for controlled temperature and humidity testing, environmental simulation, ageing tests, material testing, product validation, and quality-control studies.

2. What is the chamber volume?

The reference CTC chamber volume is 256 litres.

3. What is the temperature range without humidity?

The temperature range without humidity is -42°C to +190°C.

4. What is the temperature range with humidity?

With humidity control, the operating temperature range is approximately +10°C to +95°C.

5. What is the humidity range?

The humidity range is 10% RH to 98% RH.

6. Can it be used for electronics testing?

Yes, it is suitable for electronics reliability testing, PCB testing, humidity exposure, and temperature cycling within the supported test range.

7. Can it be used for automotive or aerospace testing?

Yes, it is suitable for controlled testing of automotive and aerospace components, materials, and assemblies when the sample size and test method match the chamber specification.

8. Does it support rapid temperature changes?

Yes, the CTC-type chamber supports rapid heating and cooling, making it suitable for accelerated environmental test cycles.

9. What is the maximum shelf load?

The reference specification lists a maximum loading of 25 kg per internal shelf.

10. Does the chamber need calibration?

Yes, calibration and verification are recommended for reliable testing, especially in quality-control, research, pharmaceutical, electronics, and regulated laboratory applications.

11. Can flammable chemicals be tested inside?

No, flammable or explosive materials should not be tested unless the chamber is specifically designed and certified for that application.

12. How should the chamber be maintained?

Keep the chamber clean, inspect door seals, verify temperature and humidity performance, maintain ventilation clearance, clean after humidity tests, and follow preventive maintenance schedules.

Why Choose StemAids?

StemAids laboratory environmental testing systems are selected for practical workflows, controlled testing, and institutional laboratory requirements. The StemAids CTC Environmental Testing Chamber supports temperature-humidity simulation, accelerated ageing, product reliability testing, material validation, electronics testing, and quality-control documentation for research, industrial, educational, automotive, aerospace, packaging, and material-testing laboratories.

SEO Keywords

StemAids CTC Environmental Testing Chamber, CTC Climatic Test Chamber, Environmental Test Chamber CTC, Temperature Humidity Test Chamber, Climate Test Chamber, Climatic Test Chamber 256 L, Accelerated Ageing Test Chamber, Material Testing Chamber, Electronics Environmental Test Chamber, Automotive Testing Chamber, Laboratory Environmental Chamber

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
USD United States (US) dollar
Product has been added to your cart
Compare (0)