The StemAids Serenit Microbio Electric Burner is a flameless laboratory heating device designed for microbiology, biology, chemistry, and educational laboratory applications. It is used as an electric alternative to a traditional Bunsen burner, especially where open flame, gas pipelines, or gas cartridges are not preferred.
Product Description
The StemAids Serenit Microbio Electric Burner is suitable for microbiology practical work, sterilization support, glassware heating, inoculating loop heating, tube warming, and general laboratory demonstrations. The unit provides high-temperature electric heating without requiring butane, propane, or natural gas.
The burner is designed to perform many procedures traditionally carried out with a Bunsen burner. It includes an integrated electronic temperature regulator for controlled heating and is supplied with a stainless steel metal accessory part for practical laboratory use.
Product Specifications
| Parameter | Details |
|---|---|
| Product Name | Serenit Microbio Electric Burner |
| Brand | StemAids |
| Product Type | Electric Bunsen burner / flameless microbiology burner |
| Heating Type | Electric heating |
| Maximum Temperature | Up to 700°C |
| Heating Performance | Can heat 100 mL of water from 30°C to 100°C in approximately 2 minutes 30 seconds |
| Temperature Control | Integrated electronic regulator |
| Rated Power | 550 W |
| Operating Voltage | 230 V, 50–60 Hz |
| Weight | Approx. 2.58 kg |
| Operating Conditions | Indoor use; ambient temperature +5°C to +40°C; maximum relative humidity 80% |
| Included Accessory | Stainless steel metal part |
| Gas Requirement | No gas required |
| Application | Microbiology sterilization support, laboratory heating, glasswork, practical demonstrations, and educational experiments |
| Suitable For | Microbiology labs, biology labs, chemistry labs, school labs, college labs, research labs, and training laboratories |
Key Features
- Electric alternative to a conventional gas Bunsen burner
- No butane, propane, or natural gas connection required
- Maximum heating temperature up to 700°C
- Integrated electronic regulator for controlled temperature adjustment
- Suitable for microbiology practical work and sterilization support
- Useful for glassware heating, loop heating, and classroom demonstrations
- Designed for indoor laboratory use
- Suitable for educational, research, microbiology, and institutional laboratories
How to Use
- Place the StemAids Serenit Microbio Electric Burner on a clean, dry, stable, level, and heat-resistant laboratory bench.
- Check the power cord, plug, housing, regulator, and heating area before use.
- Connect the unit to a suitable 230 V power supply with proper electrical safety protection.
- Switch on the burner according to the laboratory operating procedure.
- Set the required heating level using the integrated electronic regulator.
- Allow the burner to reach the required working temperature before using it for heating or sterilization support.
- Use forceps, holders, clamps, or suitable laboratory tools to handle inoculating loops, glass rods, tubes, or sample vessels.
- Position the item carefully in the heated working zone without touching the hot surface directly.
- After the procedure, switch off the unit and allow it to cool completely.
- Clean the exterior carefully after cooling and store the burner in a dry laboratory area.
Applications
- Microbiology practical work
- Sterilization support for compatible laboratory tools
- Heating inoculating loops and glass instruments
- Glass tube softening and laboratory demonstrations
- Heating small test tubes and laboratory vessels
- Biology and chemistry practical training
- School, college, and university laboratory experiments
- Research and institutional laboratory use where gas-free heating is preferred
Safety and Handling Guidelines
- Use only indoors and on a dry, stable, heat-resistant surface.
- Do not cover the device during operation, as it requires ambient air cooling.
- Never leave the burner switched on without supervision.
- Do not touch the heating zone during or immediately after operation.
- Keep paper, solvents, plastic items, loose clothing, and flammable materials away from the heated area.
- Use safety goggles, gloves, lab coat, and suitable laboratory holders during heating procedures.
- Do not operate the unit if the cord, plug, casing, or regulator is damaged.
- Keep the burner away from water splashes and wet bench surfaces.
- Allow the unit to cool completely before cleaning, moving, or storing.
- Use only under trained supervision in educational and microbiology laboratories.
FAQ
1. What is the StemAids Serenit Microbio Electric Burner used for?
It is used for microbiology practical work, sterilization support, glassware heating, loop heating, and laboratory demonstrations where an electric alternative to a Bunsen burner is required.
2. Does this burner require gas?
No, it is an electric burner and does not require butane, propane, or natural gas.
3. What is the maximum temperature?
The burner can reach a maximum temperature of up to 700°C.
4. What is the power rating?
The rated power is 550 W.
5. What power supply is required?
It requires a 230 V, 50–60 Hz electrical supply.
6. Is it suitable for microbiology laboratories?
Yes, it is suitable for microbiology applications such as sterilization support, inoculating loop heating, and practical laboratory training.
7. Can it replace a traditional Bunsen burner?
Yes, it can replace a gas Bunsen burner in many routine laboratory procedures where flameless electric heating is preferred.
8. What is included with the unit?
The set includes the Serenit Microbio electric burner and a stainless steel metal accessory part.
9. Can the burner be left switched on unattended?
No, the burner should never be left heating without operator supervision.
10. How should the burner be cleaned?
After switching off and allowing the unit to cool completely, wipe the exterior with a clean dry or slightly damp cloth. Do not immerse the unit in water.
Why Choose StemAids?
StemAids laboratory equipment is designed for practical science workflows, safer apparatus handling, and dependable daily laboratory use. The StemAids Serenit Microbio Electric Burner supports flameless heating, gas-free laboratory operation, microbiology sterilization workflows, and supervised science training for schools, colleges, research laboratories, microbiology labs, and institutional science environments.
SEO Keywords
StemAids Serenit Microbio Electric Burner, Serenit Microbio Electric Bunsen Burner, Electric Bunsen Burner for Microbiology, Flameless Laboratory Burner, Gas-Free Laboratory Burner, Microbiology Electric Burner, Electric Burner 700°C, School Laboratory Electric Burner, Electric Laboratory Heating Equipment, Bunsen Burner Alternative










Reviews
There are no reviews yet.