Quick Answer: The Technibec 2.0 electric burner, listed as ‘Technibec 2.0 Electric Beak’, is a bench-top laboratory burner that heats electrically instead of burning gas. In the listing photo it is a grey metal box with a red switch on the front and a slotted guard around an open heating zone on top.
Technibec 2.0 on the Bench
‘Beak’ in the title is a mistranslation of the French ‘bec’, meaning burner, and ‘2.0’ is the version in the model name. The photo shows a wider, longer unit than the compact Techni, with a grey casing, a red rocker switch and a slotted guard running round the top. The heating zone sits inside that guard, so tubes, loops and small vessels are brought down into it from above.
The Technibec is the only burner in this range with a dedicated microbiology table listed for it. That golden sheet-metal table is placed over the burner, with an opening above the heat and a row of holes for culture tubes, turning the unit into a compact aseptic workstation.
Without the table, the Technibec 2.0 is used like any bench burner: holding a test tube in the heat, warming the neck of a flask, or softening a short length of narrow glass tubing in a demonstration. Its guard reduces accidental contact, but the upper surfaces still reach burning temperatures during use.
Applications
- General heating of test tubes and small flasks in chemistry classes held in rooms without gas
- Aseptic transfers in microbiology when combined with the Technibec microbiology table
- Warming a tube of liquid to show a dissolving rate or colour change that speeds up with temperature
- Replacing a gas burner in a temporary lab set up for outreach events
Specifications
| Item | Technibec 2.0 electric laboratory burner |
| Listed as | Technibec 2.0 Electric Beak |
| Casing | Grey box with a slotted guard around the top (photo) |
| Switch | Red rocker switch on the front (photo) |
| Matching accessory | Microbiology table for Technibec, listed separately |
Care & Handling
- Place the Technibec 2.0 on a flat, heat-resistant surface with space around the guard for air to circulate.
- When the microbiology table is fitted, keep paper and plastic items away from its central opening.
- Switch off and unplug after use, then allow the casing and guard to cool before cleaning or storage.
- Have the cable and plug inspected periodically, as for any portable electrical appliance.
Why Choose LabEquip
Labs that want one burner model to cover both chemistry heating and microbiology bench work often choose the Technibec 2.0 with its table. Both appear in LabEquip’s chemistry lab equipment listings, and burner-and-table sets can be requested through the contact page.
Related Products
- Microbiology Table for Technibec: The golden sheet-metal microbiology table made to stand over the Technibec burner.
- Technibec 2.0 Electric Beak Pack + Table for Microbiology: The Technibec 2.0 burner and its microbiology table supplied together as a pack.
- Electric beak Techni: The compact Techni electric burner in a blue slatted cage, a smaller alternative.
- Electric Beak Dimmer: A timed power regulator whose panel names the Technibec, for setting the heat output.
Frequently Asked Questions
What is the Technibec 2.0 electric burner?
The Technibec 2.0 is a bench-top laboratory burner that heats electrically instead of burning gas. Beak in the listing title is a mistranslation of the French bec, meaning burner, and 2.0 is the version in the model name. The photo shows a grey box with a red switch and a slotted guard around an open heating zone.
How does the Technibec 2.0 differ from the compact Techni burner?
The Techni is a small unit in a blue slatted cage; the Technibec 2.0 is wider and longer, with a grey casing and a slotted guard round the top. The Technibec 2.0 is also the burner with a dedicated microbiology table made to stand over it.
Is the Technibec 2.0 burner flameless?
Yes. It heats with an electric element, so there is no gas supply and no open flame. The heating zone still gets very hot, so the usual care with hot surfaces, and with flammable liquids near the heat, still applies.
How is the Technibec microbiology table used with the burner?
The table stands over the Technibec 2.0 with its central opening above the heat. Its flat top becomes a working area for loops and dish lids, and a row of holes holds culture tubes upright near the warm zone, making a compact aseptic workstation.
What should be checked on the Technibec 2.0 before a class practical?
Check that the cable and plug are undamaged, the guard is in place, and the bench around the burner is clear of paper and solvents. Switch it on to confirm it heats, and switch it off whenever it is not in use.
What can be heated on the Technibec 2.0?
It suits work brought down into its heating zone from above: holding a test tube in the heat, warming the neck of a culture tube or sterilising a loop. For heating larger volumes of liquid, a hot plate or water bath is more suitable.
Last Updated: November 2026









Reviews
There are no reviews yet.