Pipette Tips Box

High-Impact Polypropylene Composition: Precision-molded from medical-grade, reinforced polymers to maintain dimensional stability and structural integrity throughout repeated steam sterilization cycles at 121°C.

Universal Matrix Alignment: Engineered with a standardized 96-well grid geometry that ensures seamless compatibility with both manual and multi-channel pipetting systems, facilitating rapid, friction-fit tip attachment.

₹270.00

Quick Answer: A pipette tips box is a lidded box with a perforated rack that holds disposable micropipette tips upright in a grid. The pipette is pressed straight into a tip, so tips are fitted without being touched and stay covered between uses.

Why Tips Are Racked, Not Loose

Tips bought loose in a bag must be picked up by hand and pushed onto the pipette, which transfers skin oils, dust and nucleases to the part that touches the sample. Racked in a box, each tip stands open end up; the pipette nozzle is lowered into it and pressed home. The lid keeps the remaining tips clean, and the rack holds them at an even height so the fit is consistent.

Polypropylene boxes are generally autoclavable, which allows tips to be sterilised in the rack.

Plain micropipette tips bought in bulk can be refilled into the box by gloved hand and then autoclaved. A reagent reservoir completes the set-up for multichannel work.

Specifications

Item Lidded box with perforated rack for pipette tips
Function Holds tips upright for hands-free fitting
Layout Grid of holes; many boxes use 96 positions
Sterilisation Polypropylene boxes are generally autoclavable

Care & Handling

  • Refill wearing clean gloves, touching tips only on the outside of the wide end, and close the lid straight away.
  • Autoclave with the lid closed but not tightly latched, if the design allows, and let the box dry before use.
  • Label boxes by tip size and by whether they are sterile.

Applications

  • Keeping tips ready at each student’s micropipette station
  • Sterilising tips for microbiology or molecular biology work
  • Loading eight or twelve tips at once onto a multichannel pipette
  • Refilling from bulk bags to cut down on plastic waste from pre-racked boxes

Why Choose LabEquip

Labs that have moved to micropipettes for class practicals need a box for each station and each tip size. LabEquip offers these in its chemistry lab equipment range; send your tip size and number of stations through the contact page.

Related Products

  • Pipette Tips: Plain disposable micropipette tips for routine buffers and dilutions.
  • Pipette Tips & Filter Tips: Filter tips with an aerosol barrier, racked the same way for PCR and culture work.
  • Micro Tip Box: A micro tip box with a locking, high-clarity lid for universal tips.
  • Universal Reagent Reservoir: A universal reagent reservoir for multichannel pipetting with tips taken from the box.

Frequently Asked Questions

Why are pipette tips kept in a racked box instead of loose?

A racked pipette tips box holds each tip upright in a grid, so the micropipette is pressed straight into a tip and the tip is never handled. That keeps skin oils, dust and nucleases off the part that touches the sample, and the lid keeps the remaining tips clean.

Can a tips box be refilled with loose tips?

Yes. Refill it using clean gloves or a tip-loading tray, placing tips by their wide end only. For sterile work, refill and then autoclave the closed box so the tips are sterile when the lid is next opened.

Is the pipette tips box autoclavable?

Polypropylene tip boxes are generally autoclavable. Leave the lid slightly loose or follow the box design so steam can enter, and dry the box before opening to avoid wet tips.

Will one tips box fit every size of pipette tip?

No. Each box is made for one tip size: hole spacing and depth that suit large 1000 microlitre tips will not hold small 10 microlitre ones upright. Keep separate, labelled boxes for each tip size used in the lab.

Why do multichannel pipettes need racked tip boxes?

Many tip boxes use a 96-position grid of 8 by 12, the same spacing as a 96-well plate. A multichannel pipette can then be pressed onto a full row of tips in one movement, which is not possible with loose tips.

How do I stop the tips in a box becoming contaminated?

Open the lid only when fitting a tip, close it straight after, and never return a used tip to the box. Avoid passing hands or pipettes over open rows, and discard a box of tips if liquid has been splashed into it.