Search

In Stock

Vacuum Bell Jar with Manual Pump and Pressure Gauge

Cloche à vide avec pompe manuelle et manomètre, Manual Reciprocating Pump Architecture Manomètre intégré, provides a tactile understanding of work-energy relationships and the mechanical effort required for air displacement in pneumatic systems.

Vide partiel obtenu rapidement, Optical-Grade Polycarbonate Housing Facilitates high-visibility student Analysis of physical matter behavior (e.g., sound transmission, fluid boiling points) under extreme pressure gradients.

Precision Release Valve Supports the Synthesis of controlled decompression experiments, allowing students to observe the immediate effects of atmospheric re-entry on isolated systems.

₹4,556.00

Quick Answer: This vacuum bell jar with manual pump and pressure gauge is a hand-operated vacuum set: a transparent jar sealed onto a base is evacuated with a hand pump, and the gauge shows how far the pressure has fallen. It is used for air-pressure, boiling-point and sound demonstrations where students need to see a reading as well as the effect.

What the Gauge Adds

Without a gauge a bell jar demonstration shows that something changes as air is removed; with a gauge students can say how much. Vacuum gauges on sets like this generally read the difference between the pressure inside the jar and the atmosphere outside, so the needle moves further as more air is pumped out. Converting the reading to absolute pressure means subtracting it from the day’s atmospheric pressure, a useful exercise that links the gauge to a barometer.

The numbers turn familiar demonstrations into small investigations. A partly inflated balloon or a marshmallow swells as the pressure falls, and noting its size at several gauge readings gives a rough test of Boyle’s law. Warm water begins to boil without heating once the pressure drops to its vapour pressure, and the reading at which boiling starts can be compared with a table of vapour pressure against temperature.

Specifications

Item Bell jar vacuum set with hand pump and pressure gauge
Operation Manual; no electrical supply needed
Measurement Gauge indication of the vacuum reached in the jar
Typical demonstrations Balloon expansion, boiling at reduced pressure, sound from a battery buzzer
Jar size, gauge scale and seal type Confirm at enquiry

Working with a Hand Pump

A manual pump removes a fraction of the remaining air with each stroke, so the first strokes produce a quick change on the gauge and later strokes produce smaller and smaller changes. Logging the gauge after every stroke and graphing the values reveals this pattern, which levels off at a limit set by leaks and by the dead volume of the pump. A clean rim with a thin film of vacuum grease or a good gasket makes a large difference to how low the pressure goes and how long it stays there.

Demonstrations

  • Boyle’s law estimates using a balloon and gauge readings
  • Boiling water at room temperature under reduced pressure
  • Showing that sound needs a medium, with a battery buzzer inside
  • Recording the pressure after each pump stroke

Care & Handling

  • Inspect the jar for chips or cracks before every use and never evacuate a damaged jar
  • Keep the rim and base clean, and apply only a thin film of vacuum grease
  • Release the vacuum slowly through the valve before lifting the jar
  • Keep the gauge dry; do not let water or foam be drawn towards it

Why Choose LabEquip

Teachers who want readings rather than just reactions choose this bell jar set, because the gauge lets students connect each effect to a pressure. It shares demonstrations with the simpler bell jar and manual vacuum pump and works with the baroscope; see the full physics lab equipment range or contact LabEquip for jar size and gauge details.

Frequently Asked Questions

Does the gauge show absolute pressure?

Gauges on hand vacuum sets usually show how far the pressure is below atmospheric. To find the absolute pressure in the jar, subtract the gauge reading from the atmospheric pressure measured on a barometer at the time.

Why does water boil in the jar without being heated?

Boiling starts once the vapour pressure of the water reaches the pressure acting on its surface. Lowering the pressure in the jar until it matches the vapour pressure of the warm water makes it boil at that temperature.

Why does each pump stroke change the reading less than the one before?

Each stroke removes roughly the same fraction of the air still in the jar. As less air remains, the same fraction is a smaller amount, so early strokes make big changes and later strokes only small ones.

Can Boyle’s law be verified accurately with this set?

It gives a good qualitative check and rough numbers using a balloon or a trapped bubble. Accurate verification needs a dedicated Boyle’s law apparatus with a calibrated volume scale.

Why does the jar stay stuck to the base after pumping?

The atmosphere presses on the outside of the jar while little pressure pushes from inside. Opening the release valve lets air back in and frees the jar.

What should never be put in the evacuated jar?

Sealed glass containers, live animals and anything that could burst or release harmful vapour. Use balloons, marshmallows, water and battery-powered sound sources that are known to be safe at low pressure.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
INR Indian rupee
Product has been added to your cart
Compare (0)