Quick Answer: A thermoelectric pile, or thermopile, is a radiation detector made of many thermocouple junctions connected in series, with one set of junctions behind a blackened receiving surface and the other kept near the surrounding temperature. Radiation falling on the surface warms the hot junctions and produces a small voltage proportional to the absorbed power.
Many Thermocouples Working Together
A single thermocouple, two different metals joined at a junction, produces a voltage when its junction is at a different temperature from the reference junction: the Seebeck effect. The voltage is tiny, typically tens of microvolts per kelvin for common metal pairs. Connecting dozens of thermocouples in series adds their voltages, so the thermoelectric pile gives a usable signal from a very small temperature rise.
The receiving junctions sit behind a blackened surface that absorbs radiation across a wide range of wavelengths, while the reference junctions are attached to a larger mass that stays near room temperature. Many thermopiles have a conical or tubular shield in front of the surface that limits the field of view and cuts out stray radiation from the side. The output is read on a sensitive voltmeter or a measuring amplifier.
Care & Handling
- Never touch the blackened receiving surface; it is fragile and easily damaged
- Fit the protective cover or cap when the detector is not in use
- Shield it from draughts and from your own body heat during readings
- Do not point it at very intense sources such as sunlight focused by a lens
Experiments with a Thermopile
Because its response is nearly independent of wavelength, a thermopile is the classic detector for thermal radiation practicals. Facing a Leslie cube, it compares the radiation from black, white, polished and dull faces at the same temperature. Moved along a bench from a small lamp, it tests the inverse square law. Pointed at a heated body whose temperature is varied, it shows radiated power rising steeply with temperature, the basis of the Stefan-Boltzmann law.
Specifications
| Item | Thermopile (thermoelectric pile) radiation detector |
| Principle | Seebeck effect in many series-connected thermocouples |
| Output | Small DC voltage proportional to absorbed radiant power |
| Readout | Sensitive voltmeter, microvoltmeter or measuring amplifier |
| Sensitivity, aperture and connections | Confirm at enquiry |
Applications
- Comparing radiation from the faces of a Leslie cube
- Verifying the inverse square law for a small source
- Investigating the Stefan-Boltzmann law with a heated body
- Measuring relative radiation intensities across a spectrum
Why Choose LabEquip
Physics departments choose a thermopile because it measures radiation itself rather than the temperature of an object, which makes the radiation laws testable with real numbers. It suits the infrared test bench and comparisons with the thermal radiation of hot bodies lab; find more physics lab equipment in the category, or contact LabEquip about a matching meter.
Frequently Asked Questions
What is the difference between a thermocouple and a thermopile?
A thermocouple is a single pair of junctions and gives a very small voltage. A thermopile connects many thermocouples in series so that their voltages add, making it sensitive enough to detect radiation.
Why is the receiving surface black?
A black surface absorbs nearly all the radiation that falls on it, across visible and infrared wavelengths. That makes the thermopile’s response depend on the power received rather than on the colour of the source.
What meter is needed with a thermopile?
The output is in the millivolt or microvolt range, so a sensitive digital voltmeter, a microvoltmeter or a measuring amplifier is needed. An ordinary school multimeter may not resolve such small voltages.
How can zero drift be kept small?
Let the thermopile reach the temperature of the room before use, shield it from draughts and nearby warm objects, and take a background reading with the source covered before each measurement.
Can it measure the temperature of an object?
Not directly. It measures the radiant power reaching it, which depends on the object’s temperature, its surface emissivity and the distance. With a calibration for a given surface it can be used to compare temperatures.
How fast does a thermopile respond?
It takes a little time, often a few seconds, because the receiving junctions must warm up before the voltage settles. Readings should be taken once the meter has stopped changing.
Last Updated: October 2026










Reviews
There are no reviews yet.