Electromagnetic Force Restoration (EMFR): Utilizes advanced transducer technology and automated internal adjustment to compensate for ambient temperature fluctuations, ensuring consistent milligram-level accuracy and ultra-low hysteresis during high-frequency weighing cycles.

Bi-Directional GLP/GMP Firmware: Equipped with an integrated RS232/USB interface and specialized software that supports real-time statistical analysis and seamless data export to Laboratory Information Management Systems (LIMS) for audit-ready documentation.

₹1,420.00

Quick Answer: The Precision Balance is an electronic top-loading laboratory balance for weighing samples, reagents and apparatus quickly on an open pan. A precision balance sits between a simple school scale and an analytical balance: it reads to a few decimal places of a gram over a larger capacity, and the model is chosen to suit the work.

How a Precision Balance Differs from an Analytical Balance

Laboratory balances are grouped mainly by readability. Analytical balances read to 0.1 mg and need a closed draft shield. Top-loading models of this class typically read to 1 mg, 10 mg or 0.1 g, carry more load on a larger pan and settle faster, so they handle the many weighings in a laboratory that do not need the fourth decimal place: making up reagent solutions, weighing samples for moisture or ash tests, or finding the mass of physics apparatus.

Electronic balances measure the force of the load on the pan, either with a strain-gauge load cell or by electromagnetic force compensation, and convert that force into mass using a calibration. That is why calibration with a known mass, and recalibration when the balance is moved, matter so much.

Choosing Capacity and Readability

Two numbers decide the choice: the heaviest load, container included, and the smallest change you need to see. A useful rule is to pick a readability at least ten times finer than the tolerance you work to, so a solid that must be weighed to within 0.1 g calls for a balance reading 0.01 g. LabEquip’s listings range from milligram balances such as the 200 g/300 g model to centigram balances of kilogram capacity such as the 600 g/1000 g model.

Specifications

Type Electronic laboratory balance, top-loading
Readability class Usually 1 mg, 10 mg or 0.1 g for this class
Operation Weigh, tare and calibrate with a known mass
Typical uses Reagent preparation, sample weighing, mass of apparatus
Capacity, readability and pan size of this listing Confirm at enquiry

Applications

  • Weighing reagents for solutions in school and college chemistry practicals
  • Measuring masses for density, specific heat and momentum experiments in physics
  • Weighing samples before and after drying or ignition
  • Checking fill weights and portions in food and pharmacy laboratories

Care & Handling

  • Place the balance on a firm, level surface away from fans and open windows.
  • Calibrate with a known mass after installation and whenever the balance is moved to another room.
  • Do not drop objects onto the pan; shock loads can damage the weighing cell.
  • Clean spills from the pan at once and keep liquids away from the display and keys.

Why Choose LabEquip

Top-loading balances are the everyday weighing instrument of school, college and industrial laboratories, so departments often buy several. LabEquip lists this one in its physics lab category together with models of stated capacity and readability. Tell us what you need to weigh and how finely through the contact page, and a suitable model can be matched.

Frequently Asked Questions

How do I choose the readability I need?

Work out the tolerance on your weighings and choose a balance that reads at least ten times finer. For example, weighing to within 0.01 g calls for a readability of 0.001 g.

Why does the reading change when I move the object around the pan?

This is eccentric loading error, a small difference in reading depending on where the load sits. Place objects in the centre of the pan, and have the balance adjusted if the difference grows beyond what your work can accept.

Can a precision balance replace an analytical balance?

Only where 0.1 mg readability is not needed. For quantitative analysis and for weighing primary standards or samples of a few hundred milligrams, an analytical balance is required.

Why must the balance be recalibrated after moving it?

An electronic balance measures a force, and gravity varies slightly with latitude and height above sea level. A balance calibrated in one place can read differently in another, so calibrate it with a known mass where it will be used.

What does the stability indicator mean?

It shows that successive readings have stopped changing beyond a set limit. Record or tare only when it appears; reading earlier captures the value while the pan is still settling.

Why do two balances give slightly different readings for the same object?

Each works within its own calibration tolerance, and they may stand on benches with different levels or vibration. Calibrate both with the same known mass where they are used; the remaining difference should be a few counts of the last digit.

Last Updated: October 2026