Search

In Stock

Precision Balance – 200g/300g – 0.001g

High-Performance Monobloc Transducer: Engineered with an electromagnetic force restoration (EMFR) sensor to deliver 1mg resolution with ultra-low hysteresis, ensuring rapid stabilization and consistent linearity across the entire 300g capacity for sensitive analytical workflows.

Intelligent Environmental Compensation: Features advanced digital filtering and adjustable ambient vibration suppression, allowing the balance to maintain metrological integrity in diverse laboratory conditions while providing seamless GLP-compliant data export via integrated RS232/USB interfaces.

₹1,390.00

Quick Answer: The Precision Balance – 200g/300g – 0.001g is an electronic laboratory balance listed in 200 g and 300 g capacity versions, both displaying mass to 0.001 g (1 mg). This milligram precision balance is used where weighings need three decimal places but not the 0.1 mg of an analytical balance.

Milligram Readability on a Top-Loading Balance

Three decimal places put this balance in the overlap between precision and analytical weighing. A one-milligram display is fine enough for preparing most school and college reagent solutions, weighing seeds or small tablets one by one, or following the small mass changes in a chemical reaction, yet the balance settles more quickly than a 0.1 mg instrument.

At 1 mg, air movement already affects the last digit. Milligram balances usually have a draft ring or a small draft shield around the pan, and where one is fitted it should stay in place while weighing.

200 g or 300 g

The two versions share the same readability, so the choice depends on the heaviest container and sample you expect to weigh. A 250 mL beaker holding 100 mL of solution can come close to 200 g, so the 300 g version suits users who weigh into glassware, while 200 g is enough for work in weighing boats and small bottles.

Applications

  • Rate-of-reaction experiments that follow the loss of mass as a gas escapes
  • Weighing small quantities of solids for school and college reagent solutions
  • Weighing seeds, tablets or small specimens individually
  • Finding the thickness of a metal foil from its mass, area and density

Following a Reaction by Loss of Mass

A classic experiment for this balance is measuring reaction rate by mass loss. Marble chips and dilute hydrochloric acid react in a conical flask standing on the pan, with a loose plug of cotton wool in the neck. As carbon dioxide escapes, the mass falls, and readings taken every thirty seconds trace a curve that is steep at first and levels off as the acid is used up. Repeating with smaller chips or warmer acid shows how surface area and temperature change the rate.

Specifications

Type Electronic precision balance, milligram readability
Capacity 200 g or 300 g version
Readability 0.001 g (1 mg)
Typical uses Reagent weighing, small samples, reaction mass-loss experiments
Pan size, draft protection and power supply Confirm at enquiry

Care & Handling

  • Shield the milligram precision balance from air movement: switch off nearby fans and keep any draft ring around the pan in place.
  • When following a reaction on the pan, stand the flask on a small tray and plug it loosely with cotton wool so acid spray cannot reach the pan.
  • Wipe up acid or salt solutions at once; they corrode the pan and its support.
  • Calibrate with a known mass after moving the balance between rooms.

Why Choose LabEquip

Milligram balances are bought by school chemistry departments and college laboratories that need three decimal places for reagent preparation and quantitative practicals. LabEquip lists this model in its physics lab range; the slightly larger 220 g/330 g version is listed separately. Request quantities and the capacity version you prefer on the contact page.

Frequently Asked Questions

How is the rate of a reaction measured with this balance?

Put marble chips and dilute hydrochloric acid in a conical flask on the pan, plug the neck loosely with cotton wool and start a timer. Record the mass at regular intervals as carbon dioxide escapes; plotting mass lost against time gives a curve whose slope is the rate.

Why plug the flask with cotton wool?

The cotton wool lets carbon dioxide out but stops acid spray from leaving the flask. Without it, droplets would be lost as well, adding to the mass loss and making the reaction seem faster than it is.

What is the difference between the 200 g and 300 g versions?

Only the maximum load; both display 0.001 g. Choose 300 g if you weigh into beakers or flasks that, with their contents, can go over 200 g.

Is 0.001 g readability enough for preparing standard solutions?

For school and most college reagent solutions, yes. For primary standards in quantitative analysis, where a few hundred milligrams must be weighed to within a fraction of a milligram, an analytical balance reading 0.1 mg is the right instrument.

How can the thickness of a metal foil be found by weighing?

Cut a rectangle of foil, measure its length and width, and weigh it. Divide the mass by the area and by the density of the metal; the result is the average thickness, which is too small to measure reliably with a ruler.

Why does the reading drift with a beaker of liquid on the pan?

Liquids evaporate, and warm liquids also set up convection currents, so the mass slowly falls. Cover the beaker with a watch glass where possible, and let warm solutions cool to room temperature before weighing.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
INR Indian rupee
Product has been added to your cart
Compare (0)