Moisture Analyzer – 60g/0.1mg

Halogen Infrared Heating Matrix: Employs a high-efficiency circular halogen lamp for uniform thermal distribution, enabling rapid, reproducible drying cycles with programmable temperature increments up to 200°C for diverse sample matrices.

Ultra-Resolution Electromagnetic Sensor: Features an internal weighing cell with 0.1mg (0.0001g) readability, providing the forensic-level mass sensitivity required for measuring minute moisture percentages in low-mass or high-value chemical samples.

₹1,542.00

Quick Answer: The Moisture Analyzer – 60g/0.1mg is a laboratory instrument that combines a balance reading to 0.1 mg with a heating unit and measures moisture by loss on drying: it weighs a sample, heats it and reports the mass lost as a percentage. It takes samples up to 60 g and is used for foods, grains, pharmaceuticals, plastics and soils.

How Loss on Drying Works

This instrument does in one unit what the oven method does with a separate balance and drying oven. The sample is spread on a sample pan inside the analyzer and weighed; the heater then raises it to a set drying temperature while the built-in balance follows the mass as water evaporates. When the rate of mass loss falls below a set limit, the test ends and the display shows moisture content, usually as a percentage of the starting (wet) mass, or alternatively as dry content.

Results arrive in minutes rather than the hours of oven drying, which is why the method is used for in-process checks. The method counts everything that leaves the sample when heated, though, so solvents or decomposition products are counted as moisture too.

Specifications

Type Loss-on-drying instrument: balance plus heating unit
Maximum sample mass 60 g
Readability 0.1 mg
Method Loss on drying
Results Moisture or dry content in percent
Heater type, temperature range and sample pan size Confirm at enquiry

Getting Repeatable Results

Three choices govern the result: sample size, drying temperature and switch-off criterion. A thin, even layer dries uniformly; a heap dries on the outside and stays damp within. The temperature should be high enough to drive off water quickly without scorching the sample, which shows as browning and a falsely high result. Methods are usually set up by comparing the analyzer’s result with a reference oven method on the same material and adjusting the settings until they agree. With 0.1 mg readability, small samples of a gram or two still give a precise percentage.

Applications

  • Moisture checks on grains, flour, spices and other foods
  • Loss on drying of pharmaceutical granules and powders
  • Moisture in plastic granules before moulding
  • Water content of soils and sediments in environmental work

Care & Handling

  • Let the instrument cool before cleaning; the sample chamber and heater become very hot.
  • Use clean sample pans for every test; residues bake on and affect later results.
  • Do not dry samples wet with flammable solvents or materials that release hazardous vapours unless the instrument and room are suited to them.
  • Check the weighing function with a known mass at regular intervals.

Why Choose LabEquip

Food, pharmaceutical and plastics laboratories use loss-on-drying instruments for quick, repeatable checks during production and incoming inspection. LabEquip lists this 60 g, 0.1 mg model in its physics lab category, alongside the touch screen moisture analyzer. For heater type and temperature range, ask through the contact page.

Frequently Asked Questions

How is a moisture analyzer different from a drying oven?

An oven dries samples for hours, and they must be weighed separately before and after. The analyzer heats and weighs at the same time and stops when the mass stops falling, giving a result in minutes. For a new material, its settings are usually matched to an oven reference method.

What drying temperature should be used?

It depends on the material: hot enough to drive off the water quickly, but not so hot that the sample browns, melts or decomposes. Settings are normally established by comparing results with an oven reference method on the same product.

Why does a thick sample take longer and sometimes give a different result?

A thick layer dries from the top down, so the inside stays moist for longer, and the surface may scorch before the core is dry. A thin, even layer of a few grams usually dries faster and more uniformly.

What is the difference between moisture content and dry content?

Moisture content is the mass lost as a percentage of the starting mass. Dry content is what remains, so the two add up to 100 percent. Some industries also express water relative to the dry mass, which gives a larger number.

Does the analyzer measure only water?

No. It measures all the mass lost on heating, which includes alcohol, other solvents and volatile compounds. Where only water must be measured, a water-specific method such as Karl Fischer titration is used.

How does it compare with a handheld grain moisture meter?

Handheld meters estimate moisture from the electrical properties of grain and need a calibration for each crop. A moisture analyzer measures the mass lost on drying directly, so it is often used as the reference against which quicker meters are checked.