In Stock

Lummer-Brodhun Photometer

High-Transmission Lummer-Brodhun Cube: Utilizes two optically matched right-angled glass prisms with a precision-ground central contact area, creating a concentric visual field for seamless brightness matching with near-zero parallax error.

Micrometer-Controlled Positioning: Integrated with a heavy-duty graduated optical bench and rack-and-pinion drive, providing the sub-millimeter displacement accuracy required to strictly adhere to the inverse-square law during sensitive intensity evaluations.

₹750.00

Quick Answer: The Lummer-Brodhun photometer is an optical instrument that compares the luminous intensities of two light sources by matching the brightness of two fields seen side by side through an eyepiece. On a photometer bench the head is moved between two lamps until the fields match, and the inverse square law then gives the ratio of their intensities.

Inside the Photometer Head

In the classic design a white, diffusing screen inside the head is lit on one face by each lamp. Mirrors or prisms carry the light from the two faces to the Lummer-Brodhun cube, made of two right-angled prisms pressed together along their long faces. On one prism that face is ground away except for a central area, so where the glass is in optical contact light passes straight through, and where it is not, light is totally internally reflected.

Looking into the eyepiece, the observer therefore sees one region lit by one face of the screen and the surrounding region lit by the other. When the two faces receive equal illumination, the boundary between the regions fades almost completely. The eye is poor at judging absolute brightness but very good at spotting a boundary between two neighbouring patches, and this design makes use of exactly that ability.

Measuring With the Inverse Square Law

The two lamps are set at the ends of a photometer bench or optical bench with the head between them. At the balance position, the illumination on each face is equal, so the intensities satisfy I1/d1² = I2/d2², where d1 and d2 are the distances from each lamp to the screen. Measuring both distances gives the ratio I1/I2 = (d1/d2)².

Good practice is to approach the balance point from both sides and average, then turn the head through half a turn and repeat, so that any difference between the two sides of the screen cancels out.

Experiments

  • Comparing the luminous intensities of two lamps
  • Verifying the inverse square law by moving one lamp and re-balancing
  • Finding the fraction of light transmitted by a glass plate or filter placed in one beam
  • Comparing light output per watt for lamps of different types

Specifications

Type Visual photometer head of the Lummer-Brodhun cube design
Measures Ratio of the luminous intensities of two sources
Used with A photometer or optical bench and two lamps
Reading method Matching two adjacent fields by eye
Mounting, eyepiece and bench compatibility Confirm at enquiry

Care & Handling

  • Keep fingers off the optical faces and eyepiece; clean glass only with a soft lens tissue.
  • Keep the Lummer-Brodhun photometer head closed and dust-free when not in use.
  • Allow lamps to cool before moving them, and keep their leads away from the bench edge.
  • Work in a darkened room and screen off stray light from windows and other lamps.

Why Choose LabEquip

Colleges and universities buy a Lummer-Brodhun head for photometry practicals in which students measure, rather than just observe, how light spreads from a source. LabEquip lists it with its physics lab equipment, and a table lamp or other steady source completes a basic set-up. Ask about bench and lamp options through the contact page.

Frequently Asked Questions

Why does the boundary between the fields disappear at balance?

When both faces of the screen are equally illuminated, the two regions seen through the cube are equally bright. With no difference in brightness, the eye can no longer see where one region ends and the other begins.

Why is the head turned round during a measurement?

The two faces of the screen and the two optical paths may not be perfectly identical. Taking readings with the head in both orientations and averaging them cancels any such difference.

Does the room need to be dark?

Yes. Stray light from windows or other lamps falls unequally on the two faces of the screen and shifts the balance point, so photometry is done in a darkened room with the bench screened.

Can lamps of different colours be compared?

Only with difficulty. When the two fields differ in colour the eye cannot judge equal brightness well. Results are most reliable when both lamps give light of similar colour.

How is the transmission of a filter measured?

Balance the photometer, then place the filter in one beam and re-balance by moving the head. The ratio of the squared distances before and after gives the fraction of light the filter transmits.

Does the inverse square law hold at any distance?

It holds well when each lamp is small compared with its distance from the screen, so that it behaves like a point source. Very short distances to a large lamp give errors.

Last Updated: October 2026