Search

In Stock

Lighting Test Bench

Banc d'essai éclairage enables student quantification of electrical consumption and circuit efficiency, reinforcing "Analyze" and "Evaluate" level proficiencies in electrical engineering units.

Standardized Photometric Assessment Port supports accurate student readings of illuminance (Lux) and luminous efficacy, allowing for evidence-based cost-benefit modeling and sustainability analysis.

₹12,560.00

Quick Answer: This lighting test bench holds lamps of different technologies in lamp holders, typically behind a protective cover, so they can be switched on safely and compared side by side. Students use the lighting test bench to measure how much light each lamp gives for the electrical power it takes, and how that light is spread around the lamp.

Measuring Light Properly

Comparing lamps fairly needs the right quantity. A lamp’s total light output is its luminous flux, in lumens; what a light meter (luxmeter) reads is illuminance, in lux, the flux arriving on each square metre of the surface where the meter sits. Illuminance falls with distance from the lamp, roughly as the inverse square for a small source, so every lamp must be measured with the meter at the same distance and angle. Dividing light output by electrical power gives luminous efficacy in lumens per watt, the figure that separates efficient lamps from wasteful ones.

In class the comparison is usually relative: the same meter, the same position, the same warm-up time, and the electrical power read from an energy meter or the lamp’s marking. The ranking that emerges, with LED lamps well ahead of filament and halogen lamps, is the point of the exercise, and students can explain it from the way each technology produces light.

What Students Measure

  • Comparing the luminous efficacy of LED, halogen and other lamps
  • Plotting the light distribution around a lamp
  • Recording warm-up curves after switch-on
  • Supporting lessons on household energy use

Light Spread and Warm-Up

Lamps differ not only in how much light they give but in where it goes. Moving the luxmeter around a lamp at a fixed distance and recording illuminance at several angles builds a simple light distribution diagram: a bare filament spreads light almost evenly, while many LED lamps send most of it forwards. That explains why a lamp with a high lumen figure may still light a desk less well than a directional one.

Timing matters too. Some lamp types reach full output only after a warm-up period, while LEDs and filament lamps are bright almost at once. Logging illuminance every few seconds after switch-on shows the difference and reminds students to wait before taking comparison readings. LabEquip also lists a two-lamp test bench for simpler side-by-side comparisons.

Specifications

Item Bench for testing and comparing lighting systems
Purpose Side-by-side comparison of lamp technologies
Used with Luxmeter, plug-in energy meter and timer
Quantities compared Luminous efficacy, light distribution, warm-up behaviour
Lamp positions, enclosure and supply Confirm at enquiry

Care & Handling

  • Light the lamps only with any protective cover in place and a teacher present
  • Disconnect the mains plug and wait for hot lamps to cool before swapping them
  • Look over the lead and plug before every session; a damaged lead means the bench stays out of use
  • Send spent lamps to a lamp recycling point rather than general waste

Why Choose LabEquip

Schools teaching energy efficiency and the physics of light buy the bench to turn lamp labels into measured results. LabEquip supplies it with other physics lab equipment; ask about lamp sets and the mains supply through LabEquip contact.

Frequently Asked Questions

What is the difference between lumens and lux?

Lumens measure the total light a lamp gives out. Lux measure how much of that light lands on each square metre of a surface, so a lux reading depends on distance and direction.

How do we compare the efficiency of lamps?

Divide each lamp’s light output by the electrical power it uses. The result, luminous efficacy in lumens per watt, shows how much light each watt produces.

Why must the luxmeter stay at the same distance?

Illuminance falls quickly with distance, roughly as the inverse square for a small lamp. Moving the meter even a little changes the reading more than the difference between lamps.

Why do LED lamps usually come out on top?

An LED produces light directly in a semiconductor, while a filament lamp first heats a wire until it glows and wastes most of its input as heat.

What is a light distribution diagram?

It is a plot of illuminance at different angles around a lamp, taken at a fixed distance. It shows whether a lamp spreads its light evenly or concentrates it in one direction.

Can students use the bench themselves?

Yes, under supervision, as long as lamps are lit only with any protective cover in place and are changed only after unplugging and cooling.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top