Quick Answer: The Copper Wire for Resistors is copper conductor wire used to wind low-value resistance coils and to study how a wire’s resistance depends on its length, thickness and temperature. Because pure copper’s resistance changes noticeably with temperature, copper wire for resistors is a common sample for the temperature coefficient of resistance experiment.
Resistance, Length and Cross-Section
The resistance of a uniform wire is R = ρL/A, where L is its length, A its cross-sectional area and ρ the resistivity of the material. Copper’s resistivity is very low, which is why it is used for connecting leads; to make a coil with a useful resistance, a long length of thin copper wire is needed, wound on a former so that it takes up little space.
Measuring the resistance of different lengths with a meter bridge or the ammeter-voltmeter method, and the diameter with a micrometer screw gauge at several points, lets students plot R against L and calculate the resistivity from the gradient. Doing the same for a constantan or nichrome wire shows why those alloys, not copper, are chosen for heating elements and standard resistors.
The Temperature Coefficient Experiment
For this experiment a coil of the copper wire is wound non-inductively, insulated against water, and immersed in a beaker of water or oil with a thermometer and stirrer. Its resistance is measured with a meter bridge or post office box at a series of temperatures as the bath is heated. The graph of resistance against temperature is a straight line, and its gradient divided by the resistance at 0 °C gives the temperature coefficient of resistance. Copper’s coefficient is many times that of constantan, whose resistance hardly changes, which is why copper coils make simple resistance thermometers and why standard resistors avoid copper.
Specifications
| Material | Copper conductor wire |
| Purpose | Winding resistance coils; resistivity and temperature coefficient experiments |
| Key property | Low resistivity with a marked rise in resistance on heating |
| Measured with | Meter bridge, post office box or voltmeter-ammeter method |
| Gauge, insulation and length supplied | Confirm at enquiry |
Practicals
- Determining the temperature coefficient of resistance of copper
- Finding the resistivity of copper from resistance against length
- Comparing copper with constantan or nichrome resistance wire
- Winding small coils and simple resistance thermometers
- Showing how a wire’s resistance rises as it warms with current
Care & Handling
- Cut only the length needed and keep the rest wound on its reel to avoid kinks, which change the cross-section locally.
- Remove any insulation only where contact is needed, and clean the ends bright so the joint adds no extra resistance.
- Store the reel dry so the copper surface does not tarnish.
- Check that a coil immersed in water is fully insulated before taking readings.
Why Choose LabEquip
Colleges and senior schools order this wire in reels for the resistance and temperature-coefficient practicals that recur every term. LabEquip lists it in Physics Equipments; the meter bridge is the usual instrument for measuring the coils. Send gauge and length requirements via the LabEquip contact page.
Frequently Asked Questions
Why is copper used for the temperature coefficient experiment?
Pure copper’s resistance rises noticeably and almost linearly with temperature over the range of a water bath, giving a clear straight-line graph. Alloys such as constantan change so little that the effect is hard to measure in a school laboratory.
Why are standard resistors not made from copper?
A standard resistor must keep the same value as room temperature changes. Copper’s resistance drifts with temperature, so resistance boxes use alloys such as manganin or constantan, whose resistance is almost constant.
How should the coil be wound for resistance measurements?
Wind it non-inductively by folding the wire in half and winding the double strand, so currents in neighbouring turns flow in opposite directions. This cancels the coil’s magnetic field and avoids inductive effects when the bridge is balanced.
Why does thin copper wire get hot in a circuit?
Its resistance is larger than that of thick wire, and the heating power is I²R. A large current through thin wire therefore heats it, and as it warms its resistance rises further. Keep currents small during measurements.
How do I measure the diameter accurately?
Use a micrometer screw gauge, taking readings at several points along the wire and in two directions at right angles at each point. Average them; because area depends on diameter squared, a small diameter error doubles in the resistivity result.
Can I use this wire to make an electromagnet?
Yes, if the wire is insulated. Wound in many turns around a soft iron core and connected to a low-voltage supply, it forms an electromagnet. Bare wire must not be wound into touching turns, or the current short-circuits across them.
Last Updated: October 2026