Clement & Desormes’ Apparatus

High-Volume Stabilized Glass Vessel: Features a 10-liter reinforced carboy optimized for minimizing ambient heat transfer, ensuring the integrity of the adiabatic process during rapid pressure release.

Precision U-Tube Manometry System: Integrated with a high-visibility liquid manometer and a micro-leak-tested three-way stopcock, allowing for high-resolution differential pressure readings across sequential thermodynamic states.

₹6,050.00

Quick Answer: Clement and Desormes’ apparatus determines gamma, the ratio of the specific heat of a gas at constant pressure to that at constant volume, using air in a large closed vessel, a manometer and a stopcock. A quick adiabatic expansion followed by warming back to room temperature gives two pressure readings from which gamma is calculated.

The Ratio of Specific Heats

A gas heated at constant pressure needs more heat for each degree than the same gas heated at constant volume, because it also does work as it expands. The ratio of the two specific heats, gamma, depends on how the molecules can store energy: it is close to 1.67 for monatomic gases and close to 1.4 for diatomic gases such as the nitrogen and oxygen in air. Measuring gamma for air is therefore a direct test of the kinetic theory taught in thermodynamics.

Nicolas Clement and Charles Desormes devised the method in the early nineteenth century. The Clement and Desormes apparatus consists of a large glass vessel fitted with a stopcock that opens to the atmosphere, a connection to a hand pump or bulb, and a manometer that shows the excess pressure of the air inside.

Three Stages of the Experiment

First, a little air is pumped in and the tap to the pump is closed. Compression warms the air, so the manometer reading falls slowly as the gas returns to room temperature; once it is steady, the difference in levels, h1, is recorded.

Second, the stopcock is opened for a moment and closed again as soon as the pressure has dropped to atmospheric. The expansion is so quick that almost no heat enters, so it is adiabatic and the air inside cools. Third, the air warms back to room temperature at constant volume, the pressure rises again, and the new steady difference, h2, is read. Gamma is given by h1 divided by (h1 minus h2).

Specifications

Type Apparatus for the ratio of specific heats of air (gamma)
Main parts Large glass vessel, stopcock to atmosphere, pump connection, manometer
Measured quantities Two steady manometer level differences, h1 and h2
Working fluid Air at room temperature
Vessel size, manometer liquid and pump supplied Confirm at enquiry

Applications in Teaching

  • Determining gamma for air and comparing it with the value expected for a diatomic gas
  • Illustrating adiabatic and isochoric changes on a pressure-volume diagram
  • Supporting lessons on the first law of thermodynamics and the specific heats of gases
  • Practising manometer readings and repeat measurements to estimate uncertainty

Care & Handling

  • Pump in only a small excess pressure; a large glass vessel must never be over-pressurised.
  • Check the vessel for cracks or chips before each class and keep it in its stand or crate.
  • Grease the stopcock lightly so it opens and closes quickly without sticking.
  • Keep the manometer liquid clean and topped up to the marked level.

Why Choose LabEquip

Undergraduate and senior-school physics laboratories buy Clement and Desormes’ apparatus for the thermodynamics practical on the specific heats of gases. LabEquip offers it within its physics equipment category, and the vessel size and pump arrangement suited to your bench space can be discussed through the contact page.

Frequently Asked Questions

What value of gamma should be obtained for air?

Air is mostly diatomic nitrogen and oxygen, so the expected value is close to 1.4. Student results are often a little lower, because some heat flows into the gas while the stopcock is open, so the expansion is not perfectly adiabatic.

Why must the stopcock be opened only briefly?

The pressure must fall to atmospheric before any noticeable heat flows in from the vessel walls. Opening the tap for too long lets the cooled air warm up during the expansion, which makes h2 too small and the result for gamma too low.

Why wait after pumping air into the vessel?

Compressing the air warms it. Its pressure falls as it cools back to room temperature, so h1 must be read only after the manometer level has stopped moving. The same patience is needed before reading h2.

Which liquid is used in the manometer?

Water is commonly used, sometimes coloured to make the levels easier to read. A light oil of lower density gives larger level differences for the same pressure and so improves reading accuracy. Because gamma depends on a ratio of readings, the liquid density cancels out.

Why is a large vessel used for the experiment?

In a large volume of air the exchange of heat with the walls is slow compared with the time needed to open and close the stopcock. That makes the quick expansion closer to adiabatic and gives larger, easier-to-read pressure changes.

How should the glass vessel be handled safely?

Only a slight excess pressure is needed, so never pump hard. Inspect the glass before use, keep it supported in its stand, and stand to the side rather than leaning over the vessel when pumping.