Search

In Stock

Boyle’s Law Apparatus

Integrated Pressure Gauge: Features a high-visibility Bourdon-type gauge calibrated in both bar and PSI, allowing for simultaneous monitoring of internal pressure fluctuations during manual volume adjustments.

Reinforced Measuring Cylinder: Utilizes a thick-walled, graduated tube with a built-in screw-thread safety valve to ensure airtight containment of the liquid medium even under maximum compression cycles.

$18.95

Quick Answer: The Boyle’s Law Apparatus is a gas-law set that traps a fixed mass of air above a liquid column and lets students vary its pressure while measuring its volume, showing that pressure and volume are inversely proportional at constant temperature. In the usual pattern a closed tube and an open tube on a vertical scale are joined by flexible tubing, so the open tube can be raised or lowered.

Varying Pressure with a Movable Open Tube

In the usual pattern, two glass tubes are mounted on a vertical board carrying a scale. One is closed at the top, often by a tap, and holds the trapped air; the other is open to the atmosphere. Thick-walled flexible tubing joins their lower ends, and the liquid in the system stands in both. Sliding the open tube upward raises its liquid level above that in the closed tube, so the trapped air is compressed; lowering it lets the air expand.

The pressure of the trapped air is atmospheric pressure plus h, the height of the open-tube level above the closed-tube level, taken as negative when the open level is lower. That two-way range is the main advantage of this design over a fixed J-tube: readings can be taken on both sides of atmospheric pressure in one session. The length of air in the closed tube serves as the measure of volume when its bore is uniform.

Students record h and the air length l, convert h to pressure and plot p against 1/l. The Mariotte type apparatus reads pressure and volume directly with a syringe and gauge, while the advanced oil-column apparatus pumps oil against the trapped air and reads pressure from a dial. The listing title does not state the liquid, the tube lengths or the scale fitted; if the system contains mercury, mercury-handling precautions apply.

Practical Uses

  • Verifying Boyle’s law in senior secondary physics and chemistry practicals
  • Plotting p against 1/V and p against V to compare the straight-line and curved forms
  • Finding atmospheric pressure from the intercept of a graph of h against 1/l
  • Showing that pV stays constant, within experimental error, across both compression and expansion

Specifications

Law Boyle’s law: pV constant for a fixed mass of gas at constant temperature
Usual layout Closed and open glass tubes on a vertical scale, joined by flexible tubing
Pressure variation By raising or lowering the open tube
Readings Level difference h and trapped-air length l
Liquid, tube length and scale Confirm at enquiry

Care & Handling

  • Move the open tube in small steps and wait for the levels to settle before reading.
  • Inspect the flexible tubing and its joints for cracks; a leak lets trapped air escape and spoils the series.
  • Keep the stand upright and the scale vertical so that level differences are read true.
  • If the apparatus contains mercury, work over a tray, cap the open tube when not in use and follow mercury-handling rules.
  • Avoid warming the closed tube with hands or lamps during readings.

Why Choose LabEquip

This style of Boyle’s law set is common in school laboratories because one board gives readings both above and below atmospheric pressure. Order through our Physics Equipments listing, and contact LabEquip to confirm how the set is filled.

Frequently Asked Questions

How is pressure varied in this apparatus?

By sliding the open tube up or down its stand. Raising it lifts the liquid level above that in the closed tube and compresses the trapped air; lowering it below the closed-tube level lets the air expand.

How do I calculate the pressure of the trapped air?

Measure h, the vertical height of the open-tube level above the closed-tube level, and add it to atmospheric pressure expressed as a height of the same liquid. When the open level is below the closed level, h is negative.

Why plot pressure against 1/V rather than against V?

Pressure against volume gives a curve that is hard to judge by eye. Pressure against 1/V should be a straight line through the origin, which is far easier to test and draw.

Why must temperature stay constant?

Boyle’s law applies to a fixed mass of gas at constant temperature. Warming the trapped air raises its pressure at a given volume, so readings taken as the air warms will not fit a single straight line.

How can atmospheric pressure be found from the readings?

Plot h against 1/l. The graph is a straight line whose intercept on the h axis equals minus the atmospheric pressure, measured as a height of the liquid in the apparatus.

Is a mercury-filled Boyle’s law apparatus safe for students?

It can be used safely under supervision with a spill tray and a cap on the open tube, but mercury vapour and spills are hazardous. For this reason some laboratories choose designs that use oil and a pressure gauge instead.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
USD United States (US) dollar
Product has been added to your cart
Compare (0)