Search

In Stock

Bernoulli Tube Apparatus

Precision Borosilicate Venturi Tube: Engineered with a specialized converging-diverging glass throat that ensures laminar flow transition while maintaining chemical and thermal resistance during high-pressure liquid experiments.

Integrated Multi-Point Manometer Bank: Includes six graduated vertical standpipes mounted on a stabilized backing, enabling sub-millimeter resolution for differential pressure head measurements across varying conduit diameters.

$5.36

Quick Answer: The Bernoulli Tube Apparatus is a flow demonstration in which water runs through a horizontal tube that narrows and widens again, while vertical side tubes along it show the pressure at each section. The liquid level is lowest at the narrowest part, where the flow is fastest, illustrating Bernoulli’s principle.

Pressure Falls Where Flow Speeds Up

For a liquid that is effectively incompressible, the same volume must pass every cross-section each second. This continuity rule, A₁v₁ = A₂v₂, means the liquid speeds up where the tube narrows. Bernoulli’s equation, p + ½ρv² + ρgh = constant along a streamline, then requires the pressure to drop where the speed rises, because the energy per unit volume cannot increase without work being done on the liquid.

The vertical side tubes act as simple manometers: the height of water in each one measures the static pressure where it joins the main tube. With steady flow through the Bernoulli tube apparatus, students see a high column at the wide inlet, a low one at the throat and a partly recovered column downstream. The recovery is incomplete because some energy is lost to friction and turbulence, which is itself a useful discussion point.

This is the operating principle of the Venturi meter, the carburettor and the laboratory aspirator, and it pairs well with the spouting cylinder, which shows how pressure varies with depth in a liquid at rest. The number of side tubes, the bore of the throat and the tube material are not given in the title. A steady supply from a constant-head tank or a tap with a flow-control valve gives the most stable readings. Some sets add a uniform-bore tube, along which the side-tube levels fall steadily, showing pressure lost to viscous friction even without a constriction.

Applications

  • Demonstrating Bernoulli’s principle in fluid mechanics lessons at secondary and college level
  • Relating column heights to cross-sectional areas through the continuity equation
  • Explaining the Venturi meter and estimating flow rate from a pressure difference
  • Discussing energy losses from the difference between inlet and outlet column heights

Specifications

Principle Bernoulli’s equation with the continuity equation
Layout Horizontal flow tube with a narrow section and vertical pressure tubes
Working fluid Water from a steady supply
Observation Lowest liquid column at the narrowest section
Number of side tubes, bore and connections Confirm at enquiry

Care & Handling

  • Mount the flow tube level so that column heights reflect pressure, not slope.
  • Bleed air bubbles out of the side tubes before reading; a trapped bubble distorts the level.
  • Raise the flow slowly so that water does not spill from the tops of the vertical tubes.
  • Drain completely after use and rinse with clean water to keep scale and algae out of the narrow tubes.

Why Choose LabEquip

Physics and engineering departments teaching fluid flow choose a Bernoulli tube because students read the pressure drop by eye, without gauges or sensors. It belongs to our mechanics lab equipment range; contact us about tube sizes and water connections.

Frequently Asked Questions

Why is the water level lowest at the narrow part of the tube?

The water must speed up to pass through the smaller cross-section. By Bernoulli’s principle, a rise in speed in a horizontal tube comes with a fall in static pressure, so the side tube at the throat shows the lowest column.

What is the continuity equation?

It states that, for an incompressible fluid, the product of cross-sectional area and flow speed is the same at every section of a pipe. Halving the area doubles the speed.

Why doesn’t the pressure fully recover after the narrow section?

Some energy is turned into heat by friction at the walls and by turbulence where the tube widens. The outlet column is therefore a little lower than the inlet column even where the tube widths match.

Can air be used instead of water?

Bernoulli’s principle applies equally to air, as shown by blowing between two hanging sheets of paper. With a liquid-column apparatus like this, water flow gives the clearest result because the side tubes display the pressure directly as liquid height.

How does this relate to a Venturi meter?

A Venturi meter uses exactly this arrangement in reverse: from the measured pressure difference between inlet and throat and the known areas, the flow speed and volume flow rate are calculated.

What flow conditions give the clearest result?

A steady, moderate flow from a constant-head supply. Too slow and the differences are tiny; too fast and the throat column may be drawn right down, or turbulence makes the levels flicker.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
USD United States (US) dollar
Product has been added to your cart
Compare (0)