Search

In Stock

Bending of Beam Apparatus, Koenig’s Method

Precision Hardened Knife-Edge Supports: Features a pair of heavy-gauge, adjustable cast-iron pillars with precision-ground knife edges, ensuring stable three-point loading and minimal friction during beam deflection experiments.

Dual-Mirror Optical Lever Assembly: Equipped with two high-fidelity plane mirrors mounted on specialized brackets to facilitate the Koenig method, enabling high-resolution angular slope measurements via telescope-and-scale cross-referencing.

$13.65

Quick Answer: The bending of beam apparatus for Koenig’s method determines the Young’s modulus of a material in the form of a beam. The beam rests on two knife edges and carries two small plane mirrors; as it is loaded, the mirrors tilt, and a telescope viewing a scale by reflection measures that very small tilt.

Measuring a Very Small Bend

A metal beam carrying ordinary laboratory loads bends far too little to measure with a ruler. Koenig’s arrangement measures the bend indirectly, through the angle through which the ends of the beam tilt. A plane mirror is fixed upright near each end of the beam. Light from a vertical scale reaches the telescope after reflecting from both mirrors, so the observer sees the scale through the pair of them.

When the beam is loaded, both mirrors tilt in opposite senses, and the image of the scale seen in the telescope moves. Because every reflection doubles the effect of a mirror’s rotation, and the scale is placed some distance away, a tilt of a tiny fraction of a degree produces a clear shift in the reading. The shift, together with the distance from the mirrors to the scale, gives the angle of tilt.

From that angle, the load, the distance between the knife edges and the beam’s breadth and thickness, the Young’s modulus of the beam material follows from the theory of bending. Thickness enters as its cube, which is why it must be measured carefully at several points with a micrometer screw gauge.

Applications

  • Determining the Young’s modulus of a metal beam in undergraduate elasticity practicals
  • Comparing the stiffness of beams of different materials
  • Practising the optical lever method of measuring small angles
  • Showing that the tilt of the beam ends is proportional to the load within the elastic limit

Procedure Outline

Place the beam symmetrically on the knife edges with the mirrors facing each other along the beam’s length, and set the telescope and scale so that a sharp scale image is seen. Note the reading with only the hanger in place, then add equal loads one at a time, recording the scale reading after each. Remove the loads in the same steps and record again; averaging loading and unloading readings reduces the effect of any lag in the beam.

Specifications

Method Koenig’s method, bending of a beam with mirrors, telescope and scale
Quantity determined Young’s modulus of the beam material
Support Beam resting on two knife edges
Measurements Scale shift, mirror-to-scale distance, knife-edge separation, beam breadth and thickness
Beams, telescope and scale supplied Confirm at enquiry

Care & Handling

  • Keep the mirrors clean and handle them by their mounts; fingerprints blur the scale image.
  • Add and remove loads gently so the beam does not jump on its knife edges.
  • Do not exceed loads that leave a permanent bend; check that the reading returns after unloading.
  • Store beams flat and supported along their length to avoid permanent sag.

Why Choose LabEquip

University and college physics laboratories buy apparatus for Koenig’s method to teach optical measurement of small deformations, often alongside the stretched-wire Searle’s pattern apparatus. LabEquip includes it in its physics lab equipment range, and the beams and optical accessories can be arranged through our contact page.

Frequently Asked Questions

What is the advantage of using mirrors and a telescope?

They measure the tiny angle through which the beam ends tilt. Reflection doubles the effect of each mirror’s rotation and the distant scale magnifies it further, so a bend far too small to see becomes a readable shift.

Why is the beam thickness measured so carefully?

In the bending formula, the thickness appears as its cube. A small error in thickness therefore produces a much larger error in the Young’s modulus.

Why take readings while unloading as well as loading?

A beam may not respond instantly to each load. Averaging loading and unloading readings reduces this lag and shows whether the beam has stayed within its elastic limit.

How does this method differ from Searle’s apparatus?

Searle’s apparatus stretches a wire and measures its extension. The bending method uses a beam supported at two points, which suits materials available as bars or strips rather than wires.

What materials can be tested?

Any material that can be made into a uniform rectangular beam and bends elastically under the loads used, commonly steel, brass or wood. The beams supplied with the set should be confirmed when ordering.

What should I check if the scale image is blurred?

Clean the mirrors, then refocus the telescope eyepiece on the cross-wire and the objective on the scale image. Make sure both mirrors face each other squarely so the reflected light reaches the telescope.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
USD United States (US) dollar
Product has been added to your cart
Compare (0)