The StemAids Serology Water Bath BMP30 / BMP60 is a compact laboratory water bath designed for controlled warming, incubation, thawing, and temperature maintenance of serology samples, reagents, tubes, and compatible laboratory vessels. Available in 3 L and 6 L capacity options, it is suitable for clinical laboratories, diagnostic labs, microbiology labs, biotechnology labs, research laboratories, teaching laboratories, and routine quality control applications.
Product Description
The StemAids Serology Water Bath BMP30 / BMP60 provides stable water-based heating for serology and sample preparation workflows. It is designed with a transparent polycarbonate frame, allowing easy visual monitoring of the water level and sample placement during operation. The temperature range from ambient +7°C to 60°C makes it suitable for common serology applications where controlled warming and incubation are required.
The unit includes factory preset temperature points of 37°C and 56°C, commonly used in laboratory serology and sample processing procedures. Its water-lack safety system helps protect the equipment from dry operation, while the compact design makes it suitable for bench-top laboratory use.
Product Specifications
| Parameter | BMP30 | BMP60 |
|---|---|---|
| Product Name | Serology Water Bath BMP30 | Serology Water Bath BMP60 |
| Brand | StemAids | StemAids |
| Product Type | Serologic laboratory water bath | Serologic laboratory water bath |
| Net Capacity | 3 Liters | 6 Liters |
| Temperature Range | Ambient +7°C to 60°C | Ambient +7°C to 60°C |
| Factory Setpoints | 37°C and 56°C | 37°C and 56°C |
| Construction | Polycarbonate frame | Polycarbonate frame |
| External Dimensions | 360 × 120 × 130 mm | 370 × 150 × 210 mm |
| Internal Dimensions | 280 × 110 × 80 mm | 290 × 110 × 190 mm |
| Net Weight | 1.5 kg | 2 kg |
| Gross Weight | 3 kg | 4 kg |
| Power Supply | 230 V ±10%, 50 Hz | 230 V ±10%, 50 Hz |
| Energy Consumption | 250 W | 250 W |
| Water Lack Safety | Yes | Yes |
| Optional Accessories | Polycarbonate lid, thermometer, rack for tubes | Polycarbonate lid, thermometer, racks for tubes |
| Application | Serology, sample warming, incubation, reagent heating, thawing, and laboratory temperature maintenance | |
| Suitable For | Clinical labs, diagnostic labs, microbiology labs, biotechnology labs, teaching labs, research labs, and QC laboratories | |
Key Features
- Designed for serology and routine laboratory sample warming applications
- Available in 3 L and 6 L capacity options
- Temperature range from ambient +7°C to 60°C
- Factory preset temperature points at 37°C and 56°C
- Transparent polycarbonate frame for easy visual monitoring
- Water-lack safety system helps protect against dry operation
- Compact bench-top design suitable for small and medium laboratories
- Optional lid, thermometer, and tube racks available as per requirement
How to Use
- Place the StemAids Serology Water Bath on a clean, stable, dry, and heat-resistant laboratory bench.
- Ensure the bath chamber is clean before filling.
- Fill the bath with clean water up to the recommended operating level.
- Connect the unit to a suitable 230 V power supply.
- Switch on the water bath and select the required temperature setting.
- Use the 37°C or 56°C preset where suitable for the laboratory method.
- Allow the water to reach the required temperature before placing samples.
- Place compatible tubes, sample vessels, or racks carefully into the bath.
- Maintain the samples for the required warming, thawing, or incubation time.
- After completion, remove samples carefully using gloves or suitable laboratory tools.
- Switch off the unit, allow the water to cool, clean the bath, and store it safely.
Applications
- Serology sample warming
- Clinical and diagnostic sample preparation
- Reagent heating and temperature conditioning
- Sample thawing and incubation support
- Microbiology and biotechnology workflows
- Teaching laboratory demonstrations
- Routine laboratory temperature maintenance
- Research and quality control laboratory use
Safety and Handling Guidelines
- Do not operate the water bath without sufficient water.
- Use only on a stable, level, and heat-resistant surface.
- Do not overfill the bath, as water may spill during heating or sample placement.
- Do not touch hot water or heated sample vessels directly.
- Use suitable gloves or tools when removing warmed samples.
- Keep electrical parts away from water splashes and spills.
- Clean and decontaminate the bath using suitable laboratory cleaning agents; avoid pure bleach unless approved by the equipment procedure.
- Allow the bath to cool before draining, cleaning, or moving.
FAQ
1. What is the StemAids Serology Water Bath BMP30 / BMP60 used for?
It is used for serology applications, sample warming, reagent heating, incubation support, thawing, and routine laboratory temperature maintenance.
2. What is the difference between BMP30 and BMP60?
The BMP30 has a 3 L capacity, while the BMP60 has a 6 L capacity. The BMP60 is suitable when more samples or larger vessels need to be processed.
3. What is the temperature range?
The temperature range is ambient +7°C to 60°C.
4. What are the factory setpoints?
The factory setpoints are 37°C and 56°C, which are commonly used in serology and sample preparation workflows.
5. Does the bath include water-lack safety?
Yes, the unit includes water-lack safety support to help protect the equipment against operation with insufficient water.
6. Is the bath suitable for teaching laboratories?
Yes, it is suitable for school, college, university, clinical training, diagnostic, biotechnology, microbiology, and research laboratories.
7. Can tube racks be used with this bath?
Yes, compatible tube racks may be used depending on the selected model and accessory configuration.
8. How should the serology water bath be cleaned?
After use, switch off the unit, allow the water to cool, drain the bath if required, wipe the chamber with a clean cloth, remove residues, and keep the bath dry before storage.
9. Can the bath be operated without water?
No, the bath should not be operated without sufficient water because dry operation can damage the equipment and create a safety risk.
10. Which model should I choose?
Choose BMP30 for compact 3 L sample warming needs and BMP60 for larger 6 L laboratory workflows requiring more working volume.
Why Choose StemAids?
StemAids laboratory equipment is selected for practical workflows, reliable operation, and safe daily laboratory use. The StemAids Serology Water Bath BMP30 / BMP60 supports controlled warming, simple operation, compact bench-top use, and dependable performance for clinical, diagnostic, teaching, microbiology, biotechnology, research, and quality control laboratories.
SEO Keywords
StemAids Serology Water Bath BMP30, StemAids Serology Water Bath BMP60, BMP30 Water Bath, BMP60 Water Bath, Serologic Water Bath, Laboratory Serology Water Bath, 3 L Serology Water Bath, 6 L Serology Water Bath, Clinical Laboratory Water Bath, Diagnostic Lab Water Bath, Sample Warming Water Bath, Reagent Heating Water Bath
You must be logged in to post a review.









Reviews
There are no reviews yet.