The StemAids Filtration Hood Without Connection Smart 392 / 483 / 633 / 714 is a ductless laboratory filtration hood designed for safer handling of compatible chemical vapours, solvents, acids, formaldehyde, ammonia vapours, powders, and particles when fitted with the correct filter configuration. It is suitable for schools, colleges, chemistry laboratories, pharmaceutical labs, research facilities, quality-control laboratories, and institutional science laboratories.
Product Description
The StemAids Smart Filtration Hood is designed to protect laboratory users from inhalation exposure by capturing contaminated air inside the hood and passing it through application-specific filters. Since it works without external duct connection, it supports flexible installation, reduced ducting cost, and easier laboratory layout planning.
The Smart 392, 483, 633, and 714 models are available in different working widths to match small, medium, and large laboratory applications. These hoods can be configured with activated carbon filters for chemical vapours, HEPA H14 filters for particles, ULPA U17 filters for high-efficiency particle filtration, or combined filtration depending on the laboratory process.
Important Note: This is a chemical filtration hood, not a biological safety cabinet. It should not be used for infectious biological materials, radioactive substances, explosive vapours, or unknown high-risk chemicals unless the exact configuration is approved by qualified laboratory safety personnel.
Product Specifications
| Parameter | Smart 392 | Smart 483 | Smart 633 | Smart 714 |
|---|---|---|---|---|
| Product Type | Ductless filtration hood | Ductless filtration hood | Ductless filtration hood | Ductless filtration hood |
| Brand | StemAids | StemAids | StemAids | StemAids |
| External Connection | No external duct required | No external duct required | No external duct required | No external duct required |
| Approx. External Dimensions | 1005 × 750 × 1332–1518 mm | 1298 × 750 × 1332–1518 mm | 1604–1620 × 750 × 1332–1518 mm | 1819 × 750 × 1332–1518 mm |
| Airflow | Approx. 440 m³/h | Approx. 660 m³/h | Approx. 660 m³/h | Approx. 880 m³/h |
| Air Face Velocity | 0.4 to 0.6 m/s | 0.4 to 0.6 m/s | 0.4 to 0.6 m/s | 0.4 to 0.6 m/s |
| Power Consumption | Approx. 105 W | Approx. 160 W | Approx. 160 W | Approx. 220 W |
| Voltage / Frequency | 220 V / 50–60 Hz | 220 V / 50–60 Hz | 220 V / 50–60 Hz | 220 V / 50–60 Hz |
| Sash Opening | Total opening or Reverso sash | Total opening or Reverso sash | Total opening or Reverso sash | Total opening or Reverso sash |
| Structure | Anti-acid polymer coated electro-galvanised steel | Anti-acid polymer coated electro-galvanised steel | Anti-acid polymer coated electro-galvanised steel | Anti-acid polymer coated electro-galvanised steel |
| Panels | Chemical-resistant acrylic | Chemical-resistant acrylic | Chemical-resistant acrylic | Chemical-resistant acrylic |
| Filtration Module | Polypropylene | Polypropylene | Polypropylene | Polypropylene |
| Internal Lighting | LED lighting > 650 lux | LED lighting > 650 lux | LED lighting > 650 lux | LED lighting > 650 lux |
| Filter Options | Carbon, HEPA H14, ULPA U17, or combined filtration | Carbon, HEPA H14, ULPA U17, or combined filtration | Carbon, HEPA H14, ULPA U17, or combined filtration | Carbon, HEPA H14, ULPA U17, or combined filtration |
| Work Surface Options | Tempered glass, Trespa TopLab PLUS, or 304L stainless steel | Tempered glass, Trespa TopLab PLUS, or 304L stainless steel | Tempered glass, Trespa TopLab PLUS, or 304L stainless steel | Tempered glass, Trespa TopLab PLUS, or 304L stainless steel |
| Suitable Use | Small to medium chemical handling | Medium chemical handling | Large laboratory applications | Large-capacity chemical handling |
Key Features
- Ductless filtration hood without external duct connection
- Available in 392, 483, 633, and 714 working sizes
- Suitable for compatible vapours, solvents, acids, powders, and particles
- Configurable carbon, HEPA, ULPA, or combined filtration system
- Smart monitoring interface for airflow and filter safety indication
- Air face velocity range of 0.4 to 0.6 m/s
- Chemical-resistant acrylic panels for clear visibility
- Anti-acid polymer coated steel structure for laboratory durability
- LED lighting above 650 lux for better working visibility
- Low energy consumption compared with traditional ducted fume hoods
- Suitable for schools, colleges, research labs, pharma labs, and QC labs
How to Use
- Place the StemAids Smart Filtration Hood on a stable laboratory bench or approved support stand.
- Check the chemical list, vapour type, powder type, quantity, and concentration before use.
- Select the correct filter type: carbon filter for vapours, HEPA/ULPA filter for particles, or combined filtration for mixed applications.
- Install the selected filter module correctly before switching on the hood.
- Connect the hood to the correct electrical supply as mentioned on the rating plate.
- Switch on the hood and confirm airflow status through the safety monitoring system.
- Place only the required chemicals, containers, samples, and apparatus inside the work zone.
- Keep the sash opening and airflow path clear during operation.
- Work slowly to avoid disturbing containment airflow.
- Keep chemical containers closed when they are not actively being used.
- After work, allow the hood to run for a short purge period as per laboratory SOP.
- Clean the work surface with a compatible laboratory-safe cleaning method.
- Record filter usage hours, airflow checks, and filter replacement history.
Applications
- Chemical vapour filtration
- Solvent vapour handling with correct carbon filter
- Acid and organic vapour handling with suitable filter configuration
- Formaldehyde vapour filtration with compatible filter
- Ammonia vapour filtration with compatible filter
- Powder and particle handling with HEPA or ULPA filtration
- Reagent preparation and transfer
- Sample preparation in pharmaceutical and QC laboratories
- School and college chemistry demonstrations
- Research laboratory chemical handling
- Industrial laboratory safety workflows
Safety and Handling Guidelines
- Use only with approved chemicals and known applications.
- Select the correct filter before handling any chemical or powder.
- Do not use the hood without a correctly installed filter.
- Do not use for unknown, explosive, radioactive, highly toxic, or infectious substances without formal risk assessment.
- Do not exceed the chemical quantity or filter capacity recommended by the safety assessment.
- Check airflow before each use.
- Replace saturated, expired, clogged, or incompatible filters immediately.
- Do not block the sash opening, air intake, exhaust area, or filtration module.
- Wear suitable PPE such as gloves, goggles, lab coat, and respiratory protection where required.
- Keep ignition sources away when working with flammable vapours.
- Follow SDS instructions, institutional safety rules, and local laboratory regulations.
- Allow only trained personnel to install filters, service the hood, and approve chemical use.
Quality and E-E-A-T Notes
The StemAids Filtration Hood Without Connection Smart 392 / 483 / 633 / 714 supports evidence-based laboratory safety through controlled airflow, configurable filtration, chemical compatibility assessment, filter monitoring, and documented maintenance. For safe and reliable operation, laboratories should maintain chemical lists, SDS records, filter selection documents, airflow verification records, filter replacement logs, and SOP-based user training.
FAQ
1. What is the StemAids Smart Filtration Hood used for?
It is used for ductless filtered handling of compatible chemical vapours, solvents, acids, powders, particles, and laboratory reagents.
2. Does this hood require external ducting?
No, it is a filtration hood without external connection. It filters contaminated air and returns filtered air to the laboratory room.
3. Which models are included in this range?
The range includes Smart 392, Smart 483, Smart 633, and Smart 714 models.
4. What is the difference between 392, 483, 633, and 714?
The main differences are working width, airflow capacity, power consumption, and internal working space. Larger models are suitable for larger apparatus and higher workflow capacity.
5. What filter types can be used?
Filter options include activated carbon filters for gases and vapours, HEPA H14 filters for particles, ULPA U17 filters for high-efficiency particle filtration, and combined filtration systems.
6. Can it be used for solvent vapours?
Yes, compatible solvent vapours can be handled when the correct activated carbon filter is selected and the chemical quantity is within approved safety limits.
7. Can it be used for powders?
Yes, powder handling is possible when a suitable HEPA or ULPA particulate filter is installed and the application is approved by laboratory safety personnel.
8. Is this hood a biological safety cabinet?
No, this is a chemical filtration hood. It should not be used for biological containment unless the exact system is certified for that purpose.
9. What is the air face velocity?
The reference air face velocity is 0.4 to 0.6 m/s.
10. What power supply is required?
These Smart filtration hoods commonly operate on 220 V, 50–60 Hz supply, depending on supplied configuration.
11. How often should filters be replaced?
Filter replacement depends on chemical type, concentration, quantity, operating hours, saturation indication, and laboratory safety assessment.
12. How should the hood be maintained?
Keep the work area clean, verify airflow, monitor filter condition, replace filters on time, inspect panels and seals, and document all safety checks according to laboratory SOP.
Why Choose StemAids?
StemAids laboratory safety equipment is selected for practical workflows, user protection, and institutional laboratory requirements. The StemAids Filtration Hood Without Connection Smart 392 / 483 / 633 / 714 supports ductless chemical handling, configurable filtration, flexible installation, airflow monitoring, filter safety control, and safer laboratory workflows for schools, colleges, research laboratories, pharmaceutical units, chemistry labs, and industrial quality-control departments.
SEO Keywords
StemAids Filtration Hood Without Connection Smart 392, StemAids Smart 483 Filtration Hood, StemAids Smart 633 Ductless Hood, StemAids Smart 714 Filtration Hood, Ductless Fume Hood, Chemical Filtration Hood, Laboratory Filtration Hood, Carbon Filter Fume Hood, HEPA Filtration Hood, ULPA Filtration Hood, Laboratory Safety Hood, StemAids Laboratory Equipment
You must be logged in to post a review.