Search

In Stock

Atex Drawer Freezers

65,820.00

The StemAids ATEX Drawer Freezers SFFfg Series Version 740 are spark-free laboratory freezers designed for safe frozen storage of temperature-sensitive substances in closed containers. These upright drawer freezers are suitable for laboratories handling flammable substances, chemical samples, reagents, reference materials, pharmaceutical products, and research samples requiring controlled storage between -9°C and -30°C.

Product Description

The StemAids ATEX Drawer Freezers SFFfg Series Version 740 are based on professional laboratory freezer designs with spark-free interiors and ATEX-compliant construction. They are intended for controlled storage in laboratories where ignition-source reduction inside the storage chamber is important.

The Version 740 range is available in drawer-based configurations such as SFFfg 4001 Var 740 and SFFfg 5501 Var 740. The drawer arrangement helps users organise samples, bottles, packs, boxes, and closed containers efficiently while reducing exposure time during access. These freezers are suitable for chemical laboratories, pharmaceutical labs, industrial QC labs, research institutions, universities, medical laboratories, and controlled storage rooms.

Product Specifications

Parameter SFFfg 4001 Version 740 SFFfg 5501 Version 740
Product Type ATEX / spark-free upright laboratory freezer with drawers ATEX / spark-free upright laboratory freezer with drawers
Brand StemAids StemAids
Reference Type Liebherr SFFfg 4001 Var 740 type Liebherr SFFfg 5501 Var 740 type
Temperature Range -9°C to -30°C -9°C to -30°C
Gross / Net Capacity Approx. 316 L / 190 L with drawers Approx. 499 L / 394 L with drawers
Drawer Configuration 6 drawers 8 drawers
External Dimensions Approx. 597 × 654 × 1884 mm, W × D × H Approx. 747 × 769 × 1684 mm, W × D × H
Internal Dimensions Approx. 403 × 402 × 1588 mm, W × D × H Approx. 588 × 517 × 1388 mm, W × D × H
Cooling System Static cooling Static cooling
Defrosting Manual defrost Manual defrost
Energy Consumption Approx. 384 kWh/year or 1.052 kWh/24 h Approx. 516 kWh/year or 1.414 kWh/24 h
Noise Level Approx. 49 dB(A) Approx. 49 dB(A)
Refrigerant R290, depending on supplied model R290, depending on supplied model
Mains Connection 220–240 V, 50 Hz 220–240 V, 50 Hz
Approx. Weight Approx. 82 kg for drawer version Approx. 106 kg for drawer version
Interior Safety Spark-free / ignition-source-free interior for suitable closed containers Spark-free / ignition-source-free interior for suitable closed containers
Door Steel door, lockable, reversible depending on configuration Steel door, lockable, reversible depending on configuration
Application Flammable sample storage, reagent storage, laboratory frozen storage, QC storage High-capacity flammable sample storage, reagent storage, laboratory frozen storage, QC storage

Key Features

  • ATEX-compliant spark-free interior for suitable closed-container storage
  • Adjustable freezing range from -9°C to -30°C
  • Drawer-based storage for organised sample and reagent handling
  • Available in 190 L and 394 L net drawer configurations
  • Static cooling system for laboratory freezer applications
  • Manual defrost system for controlled maintenance
  • Lockable upright cabinet for controlled access
  • Suitable for laboratories handling flammable substances in closed containers
  • Useful for chemical, pharmaceutical, industrial QC, research, and educational laboratories

How to Use

  1. Place the freezer on a clean, dry, level, and well-ventilated laboratory floor.
  2. Check that the installation area is suitable for laboratory freezer operation and has correct mains supply.
  3. Allow the freezer to stand upright after transport before connecting power.
  4. Connect the freezer to a properly grounded 220–240 V, 50 Hz power supply or as specified on the rating plate.
  5. Set the required storage temperature between -9°C and -30°C according to the stored material requirement.
  6. Allow the freezer to reach the selected temperature before loading materials.
  7. Store only compatible substances in sealed and suitable closed containers.
  8. Arrange materials in drawers with clear labelling, batch identification, and storage records.
  9. Do not overload drawers or block internal cooling airflow.
  10. Minimise door opening time to maintain stable storage temperature.
  11. Monitor temperature regularly and document readings as required by laboratory SOP.
  12. Defrost manually when frost build-up affects drawer movement or cooling efficiency.
  13. Clean the interior using a laboratory-approved method after switching off and safely removing contents.

Applications

  • Storage of flammable substances in closed containers
  • Pharmaceutical sample and reagent storage
  • Chemical laboratory frozen storage
  • Industrial quality-control sample storage
  • Research laboratory frozen material storage
  • University and institutional laboratory storage
  • Temperature-sensitive chemical reference material storage
  • Closed-container solvent-related sample storage where ATEX-rated storage is required
  • Laboratory inventory management with drawer-based segregation

Safety and Handling Guidelines

  • Store only materials compatible with the freezer rating, temperature range, and laboratory SOP.
  • Use closed, sealed, and chemically compatible containers for stored substances.
  • Do not store open volatile liquids, leaking containers, unstable chemicals, or explosive materials unless explicitly permitted by safety documentation.
  • Confirm whether the freezer classification matches the hazardous-zone and material-risk requirement before procurement.
  • Do not modify electrical parts, thermostat, wiring, drawers, or internal fittings.
  • Maintain adequate ventilation around the freezer to prevent overheating.
  • Keep the door closed and locked when not in use.
  • Use insulated gloves when handling frozen containers.
  • Follow institutional chemical storage rules, SDS instructions, and ATEX safety protocols.
  • Disconnect power before deep cleaning, servicing, or shifting the freezer.

Quality and E-E-A-T Notes

The StemAids ATEX Drawer Freezers SFFfg Series Version 740 support evidence-based laboratory storage by combining spark-free interior safety, defined temperature control, lockable access, drawer-based organisation, and controlled sample segregation. For regulated environments, users should maintain temperature records, inspect door seals, verify alarm and monitoring arrangements, follow SDS storage requirements, and document freezer qualification where required.

FAQ

1. What is the StemAids ATEX Drawer Freezer SFFfg Series Version 740 used for?

It is used for frozen laboratory storage of compatible flammable substances, reagents, chemicals, and samples in sealed closed containers.

2. What does ATEX mean in this freezer?

ATEX refers to equipment designed according to European explosion-protection requirements. In this freezer category, the interior is designed to reduce ignition-source risk for suitable closed-container storage.

3. What is the temperature range?

The adjustable temperature range is -9°C to -30°C.

4. Which drawer versions are available?

Common Version 740 drawer configurations include SFFfg 4001 Var 740 with 6 drawers and SFFfg 5501 Var 740 with 8 drawers.

5. What capacity options are available?

The SFFfg 4001 Version 740 drawer model offers approximately 190 L net drawer capacity, while the SFFfg 5501 Version 740 drawer model offers approximately 394 L net drawer capacity.

6. Is the freezer suitable for open solvent containers?

No, open solvent containers should not be stored. Materials should be stored only in suitable sealed closed containers and according to SDS and laboratory safety rules.

7. Is this a frost-free freezer?

No, these drawer freezer models use manual defrost.

8. Can it be used in pharmaceutical laboratories?

Yes, it is suitable for pharmaceutical and quality-control laboratories where the temperature range and ATEX/spark-free storage requirements match the application.

9. Does it require temperature monitoring?

Temperature monitoring is recommended for laboratory, QC, pharmaceutical, and regulated sample storage. Monitoring requirements depend on internal SOP and compliance needs.

10. What power supply is required?

Public specifications list 220–240 V, 50 Hz mains connection for these reference models. Always confirm the rating plate before installation.

11. What is the difference between SFFfg 4001 Var 740 and SFFfg 5501 Var 740?

The SFFfg 4001 Var 740 is a narrower 6-drawer model with approximately 190 L net drawer capacity, while the SFFfg 5501 Var 740 is a wider 8-drawer model with approximately 394 L net drawer capacity.

12. How should the freezer be maintained?

Keep the cabinet clean, maintain ventilation clearance, inspect door seals, defrost when needed, clean drawers safely, verify temperature performance, and service only through qualified personnel.

Why Choose StemAids?

StemAids laboratory cold-storage solutions are selected for practical workflows, controlled sample protection, and institutional laboratory requirements. The StemAids ATEX Drawer Freezers SFFfg Series Version 740 support spark-free frozen storage, organised drawer access, controlled -30°C class storage, closed-container chemical safety, and reliable workflow management for research, pharmaceutical, chemical, industrial QC, university, and institutional laboratories.

SEO Keywords

StemAids ATEX Drawer Freezer SFFfg Series Version 740, ATEX Laboratory Freezer with Drawers, SFFfg 4001 Var 740, SFFfg 5501 Var 740, Spark Free Laboratory Freezer, Explosion Proof Laboratory Freezer, Laboratory Freezer for Flammable Substances, -30°C ATEX Freezer, Chemical Storage Freezer, Pharmaceutical Laboratory Freezer, Drawer Freezer for Laboratory

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
INR Indian rupee
Product has been added to your cart
Compare (0)