Search

In Stock

Kipps Gas Generating Apparatus, Borosilicate Glass

CNC-Ground Standard Taper Joints: Features precision-machined interchangeable ground glass interfaces that ensure an airtight, hermetic seal, preventing hazardous gas leakage and maintaining internal pressure equilibrium during prolonged reactions.

Heavy-Walled Three-Chamber Assembly: Constructed with uniform wall thickness to withstand internal gas pressure, including a precision-bore stopcock for micro-metered gas elution and instantaneous reaction termination upon valve closure.

₹600.00

Quick Answer: A Kipps apparatus, or Kipp’s gas generator, is a three-bulb glass apparatus that produces a gas from a solid and a liquid acid and stops automatically when the outlet tap is closed. This version is made of borosilicate glass and is used for carbon dioxide, hydrogen and hydrogen sulfide in laboratories.

How the Three Bulbs Control the Reaction

The apparatus, named after the Dutch pharmacist Petrus Jacobus Kipp, stacks three glass globes. The top globe is a reservoir with a long tube running down to the bottom globe. The middle globe holds lumps of the solid reagent, such as marble chips, zinc granules or iron(II) sulfide, and carries the gas outlet with its stopcock. Acid poured into the top fills the bottom globe and rises into the middle one, where it meets the solid and gas is produced.

With the tap shut, fresh gas collects in the middle globe and its growing pressure drives the acid downward, through the lowest globe and back up the central tube into the reservoir, until acid and solid no longer touch. Opening the tap releases the gas, the acid returns and production restarts. This hydrostatic switch gives a steady supply for hours without pumps or electricity.

Borosilicate glass has better resistance to chemical attack and to mechanical and thermal stress than ordinary soda-lime glass, which suits an apparatus that stands charged with acid for long periods. The clear glass Kipps apparatus and the plastic Kipps apparatus work the same way.

Applications

  • Supplying hydrogen sulfide for group precipitation in classical qualitative inorganic analysis, inside a fume cupboard
  • Generating carbon dioxide by the action of dilute hydrochloric acid on marble chips, for limewater tests and fire-extinguishing demonstrations
  • Producing hydrogen from zinc and dilute acid for gas property tests
  • Providing a standing gas supply for several bench groups during a practical session

Care & Handling

  • Charge the solid through the middle globe’s opening before adding acid, using lumps large enough not to fall into the bottom globe.
  • Use dilute acid only, pour it slowly into the top globe, and lubricate the stopcock and ground joints lightly.
  • Generate hydrogen sulfide only in a fume cupboard, and close the tap fully when gas is not being drawn.
  • To discharge, drain the acid from the lower outlet into a suitable container, then rinse all three globes and the solid chamber with water.

Specifications

Item Three-globe gas generator with outlet stopcock
Material Borosilicate glass, per the listing title
Principle Closing the tap lets trapped gas drive the acid off the solid
Typical gases Carbon dioxide, hydrogen, hydrogen sulfide

Why Choose LabEquip

Colleges and senior schools that teach salt analysis with hydrogen sulfide, and laboratories wanting a durable gas supply, often specify a borosilicate Kipps apparatus. The apparatus is available from LabEquip’s chemistry lab equipment range, with capacity requests handled through the contact page.

Related Products

Frequently Asked Questions

What is a Kipps apparatus used for?

A Kipps apparatus is a three-globe glass generator that makes a gas from a solid and a liquid acid on demand. Opening the tap releases gas and closing it stops production automatically. This borosilicate version is used for gases such as carbon dioxide, hydrogen and hydrogen sulfide in laboratories.

How do the three globes of a Kipps generator control the reaction?

The top globe is an acid reservoir with a long tube to the bottom globe. The middle globe holds the solid and carries the outlet tap. With the tap open, acid rises into the middle globe and reacts; with it shut, gas pressure drives the acid back down and up into the reservoir, so the reaction stops.

Why does borosilicate glass matter in a Kipps apparatus?

The generator is not heated, but some reactions in it warm up, and the heavy globes are filled, emptied and washed with cold and warm liquids. Borosilicate glass expands very little with temperature, so it resists cracking from these changes better than ordinary glass and stands up well to acids.

Can a Kipps apparatus be heated?

No. It is designed for reactions that run at room temperature, and heating a large, thick glass vessel full of acid risks cracking it. Gases that need heat, such as chlorine from manganese dioxide and hydrochloric acid, are prepared in a flask with a thistle funnel or dropping funnel instead.

Why can’t powders be used in a Kipps apparatus?

The solid must stay on the constriction in the middle globe while acid drains away below it. Powders fall through into the lowest globe, where acid always covers them, so gas keeps forming with the tap shut and pressure builds. Use lumps such as marble chips, zinc granules or iron(II) sulfide sticks.

How is hydrogen sulfide from a Kipps generator handled safely?

Hydrogen sulfide is toxic even at low levels and dulls the sense of smell, so the generator must stand in a working fume cupboard, with the outlet led to the test solutions inside it. Keep the tap closed when not drawing gas and empty and rinse the apparatus in the fume cupboard.

Last Updated: November 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
INR Indian rupee
Product has been added to your cart
Compare (0)