The StemAids Technibec 2.0 Electric Beak Pack + Table for Microbiology is a flameless laboratory heating and microbiology workstation package designed for teaching, sterile-area handling, inoculation support, glasswork, heating demonstrations, and gas-free laboratory practicals. The pack includes a Technibec 2.0 electric beak and a microbiology table to support practical workflows around the hot-air heating zone.
Product Description
The StemAids Technibec 2.0 Electric Beak provides a powerful hot-air flow reaching up to 800°C, making it suitable as an electric alternative to a traditional gas Bunsen burner. It supports microbiology training, sterilization support for platinum loops, glass tube bending, capillary preparation, combustion demonstrations, and routine science practicals.
The included microbiology table raises the working area close to the burner heat source and provides a practical surface for Petri dishes, culture tubes, inoculating tools, and small laboratory accessories. This combination is suitable for school laboratories, college laboratories, microbiology labs, biology labs, chemistry labs, research labs, and institutional science training environments where gas-free heating and safer bench-top operation are required.
Product Specifications
| Parameter | Details |
|---|---|
| Product Name | Technibec 2.0 Electric Beak Pack + Table for Microbiology |
| Brand | StemAids |
| Pack Includes | Technibec 2.0 Electric Beak + Microbiology Table |
| Product Type | Electric Bunsen burner pack / flameless microbiology workstation |
| Heating Method | Electric hot-air flow heating |
| Hot Air Flow Temperature | Up to 800°C |
| Power | 460 W |
| Power Supply | 230 V, 50–60 Hz, 2P+T |
| Fuse Protection | F5A.H.250V |
| Power Indicator | Side-mounted power indicator light |
| Burner Dimensions | 180 × 100 × 140 mm |
| Burner Weight | Approx. 3 kg |
| Protective Housing | Cold casing design below 35°C |
| Gas Requirement | No butane, propane, or natural gas required |
| Microbiology Table Use | Raised work surface for Petri dishes, culture tubes, inoculation tools, and sterile-area handling |
| Compliance | CE-compliant reference design |
| Application | Microbiology training, sterilization support, glasswork, heating demonstrations, combustion studies, and gas-free laboratory practicals |
| Suitable For | School labs, college labs, microbiology labs, biology labs, chemistry labs, research labs, and institutional training laboratories |
Key Features
- Complete pack with Technibec 2.0 electric beak and microbiology table
- Electric alternative to a traditional gas Bunsen burner
- No gas line, gas cartridge, butane, propane, or natural gas required
- Hot-air flow reaches up to 800°C for practical heating applications
- Cold casing below 35°C supports safer bench-top operation
- Suitable for microbiology training and sterile-area demonstrations
- Supports sterilization of platinum loops and compatible laboratory tools
- Useful for glasswork, capillary preparation, and glass tube bending
- Microbiology table provides organized space for Petri dishes and culture tubes
- Suitable for educational laboratories and supervised science training
How to Use
- Place the Technibec 2.0 electric beak on a clean, dry, stable, level, and heat-resistant laboratory bench.
- Position the microbiology table around the burner according to the correct setup arrangement.
- Ensure the surrounding area is free from paper, solvents, plastic items, loose clothing, and flammable materials.
- Check the power cord, plug, fuse, casing, indicator light, table surface, and hot-air outlet before operation.
- Connect the unit to a suitable 230 V, 50–60 Hz power supply with proper earthing.
- Switch on the burner and confirm that the power indicator light is active.
- Allow the unit to preheat until the required hot-air heating performance is reached.
- Place culture tubes, Petri dishes, inoculating tools, or small accessories on the microbiology table as required.
- Use forceps, clamps, holders, or suitable laboratory tools to position loops, glass tubes, or vessels in the hot-air column.
- After use, switch off the burner and allow the burner, table, and accessories to cool completely before cleaning or storage.
Applications
- Microbiology practical training
- Sterilization support for platinum loops and compatible tools
- Petri dish handling and culture-tube organization
- Glass tube bending and capillary preparation
- Chemistry and biology heating demonstrations
- Gas-free replacement for selected Bunsen burner workflows
- Combustion and heating experiments with approved accessories
- School, college, university, and research laboratory training
- Institutional science laboratory practicals
Safety and Handling Guidelines
- Use only on a dry, stable, level, and heat-resistant surface.
- Do not touch the hot-air outlet, heated tools, or nearby hot accessories during or immediately after use.
- Keep flammable materials away from the heating area and microbiology table.
- Wear safety goggles, lab coat, heat-resistant gloves, and use proper laboratory holders during heating work.
- Do not block ventilation or cover the burner while operating.
- Do not pour liquids into or near the hot-air outlet.
- Do not operate the unit if the cord, plug, fuse, casing, table, or heating outlet is damaged.
- Never leave the electric burner switched on without supervision.
- Allow the complete setup to cool before cleaning, moving, or storage.
- Use only under trained supervision in educational and microbiology laboratories.
FAQ
1. What is the StemAids Technibec 2.0 Electric Beak Pack + Table for Microbiology used for?
It is used for flameless heating, microbiology training, sterile-area support, sterilization of compatible tools, glasswork, and teaching laboratory demonstrations.
2. What is included in the pack?
The pack includes the Technibec 2.0 electric beak and a microbiology table.
3. Does this pack require gas?
No, it is an electric burner system and does not require butane, propane, natural gas, or gas cartridges.
4. What temperature can the hot-air flow reach?
The Technibec 2.0 reference design provides hot-air flow reaching up to 800°C.
5. What is the power rating?
The burner power rating is 460 W.
6. What power supply is required?
It requires a 230 V, 50–60 Hz, 2P+T electrical supply with proper laboratory electrical safety.
7. What is the purpose of the microbiology table?
The microbiology table raises the work area near the heat source and provides organized space for Petri dishes, culture tubes, and inoculation accessories.
8. Can it replace a traditional Bunsen burner?
Yes, it can replace a traditional gas Bunsen burner for many teaching, microbiology, glasswork, and heating applications where flameless electric heating is suitable.
9. Is the casing safe to touch?
The reference design has a cold casing below 35°C, but users should still avoid the hot-air outlet and follow standard laboratory safety practices.
10. How should the unit and table be cleaned?
After switching off and allowing the complete setup to cool, wipe the burner exterior and microbiology table with a clean dry or slightly damp cloth. Do not immerse electrical parts in water.
Why Choose StemAids?
StemAids laboratory equipment is designed for practical science workflows, safer apparatus handling, and dependable daily laboratory use. The StemAids Technibec 2.0 Electric Beak Pack + Table for Microbiology supports gas-free heating, microbiology training, organized sterile-area work, glasswork, and supervised practical learning for schools, colleges, research laboratories, microbiology labs, and institutional science environments.
SEO Keywords
StemAids Technibec 2.0 Electric Beak Pack, Technibec 2.0 Electric Beak with Microbiology Table, Electric Bunsen Burner for Microbiology, Flameless Laboratory Burner Pack, Gas-Free Laboratory Burner, Microbiology Table for Electric Burner, Electric Burner 800°C, School Laboratory Electric Burner, Microbiology Training Equipment, Educational Laboratory Heating Equipment










Reviews
There are no reviews yet.