Search

In Stock

Technibec 2.0 Electric Beak Pack + Table for Microbiology

$77.27

Quick Answer: The Technibec 2.0 microbiology pack combines the Technibec 2.0 electric burner with the microbiology table made for it, listed as ‘Technibec 2.0 Electric Beak Pack + Table for Microbiology’. The listing photo shows the burner inside a raised table with a row of tube holes along the front and room for Petri dishes beside the heat.

Burner and Table as One Aseptic Station

Buying the burner and table as a pack means the two parts arrive matched. The Technibec 2.0 electric burner supplies flameless heat, and the table stands around it to turn the bench in front of the student into an organised aseptic area. ‘Beak’ in the title is the French ‘bec’, meaning burner.

In this pack photo the table is pale grey and raised on legs, with a slatted enclosure in the centre where the burner sits. Along the front edge is a row of holes, shown holding glass tubes upright, and on the right a flat area where Petri dishes can be set down within reach of the warm zone. A cable leads away at the back. The same table is also listed on its own as the microbiology table for Technibec, for schools that already have the burner.

Working at this station, a student can take a loop to the heat, open a culture tube standing in the table, transfer to a plate and close the lid without putting anything down on the open bench. The table has no heating of its own, and the area around the burner enclosure becomes hot during use.

Applications

  • Streak-plate practicals in which every student works at an identical station without an open flame
  • Broth-to-broth subculturing with both tubes held upright in the table
  • Inoculating plates on the flat area beside the heat
  • Microbiology rooms where benches are wiped with ethanol and gas flames are unwelcome

Care & Handling

  • Assemble the Technibec 2.0 pack with the burner cold and centred in the table’s enclosure before plugging in.
  • Keep plastic Petri dishes on the flat area and away from the enclosure, where the heat is concentrated.
  • Wipe the table with disinfectant only after switching off, and let alcohol-based wipes dry before switching on again.
  • Unplug and allow both parts to cool before lifting the table off the burner.

Specifications

Pack contents Technibec 2.0 electric burner and microbiology table
Table Raised top on legs with a central slatted enclosure for the burner (photo)
Tube holding Row of holes along the front edge (photo)
Working area Flat space beside the burner for Petri dishes (photo)

Why Choose LabEquip

Microbiology teachers setting up several identical student stations tend to order the Technibec 2.0 as this pack rather than as separate items. It belongs to LabEquip’s chemistry lab equipment range; say how many stations you need on the contact page.

Related Products

Frequently Asked Questions

What is in the Technibec 2.0 microbiology pack?

The pack combines the Technibec 2.0 electric burner with the microbiology table made for it. In the listing photo the pale grey table stands on legs around the burner, with a row of tube holes along the front and a flat area beside the heat where Petri dishes can be set down.

Does the table in the Technibec pack heat anything itself?

No. The table is an unpowered stand; all the heat comes from the Technibec 2.0 burner in its central enclosure. The table organises the space around that heat so tubes, loops and dishes have a place close to the warm zone.

Can the burner from the pack be used without the table?

Yes. The Technibec 2.0 works as an ordinary electric bench burner on its own, for heating test tubes or sterilising loops. The table is added when a class needs an organised aseptic station.

Why use an electric burner for school microbiology?

An electric burner needs no gas supply and gives no open flame, which removes the risk of a flame being left burning unseen or setting hair or sleeves alight. The heating zone still sterilises loops and warms tube necks, which is what aseptic technique needs.

How is a loop sterilised at the Technibec station?

Hold the loop in the heating zone until the whole wire glows red, then let it cool for a few seconds in the air above the station before taking culture. Return the used loop to the heat before putting it down.

Where should Petri dishes be placed at the Technibec station?

Use the flat area beside the burner shown in the pack photo, within reach of the warm zone but not over the heat. Open each dish only partly, lid held above it, and close it as soon as the transfer is done.

Last Updated: November 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
USD United States (US) dollar
Product has been added to your cart
Compare (0)