Search

In Stock

Malus’s Law using Diode Laser

Stabilized Semiconductor Source: Integrated 650nm diode laser featuring regulated circuitry to eliminate intensity fluctuations, ensuring a constant I 0 baseline for high-accuracy trigonometric correlation across extended experimental cycles.

Precision Angular Metrology: Features a 360-degree graduated rotary analyzer with 1-degree resolution, paired with a high-sensitivity silicon photodetector engineered for linear response across a wide dynamic range of luminous flux.

₹1,156.00

Quick Answer: The Malus Law using Diode Laser set is a polarisation experiment in which a diode laser beam passes through a polariser and a rotatable analyser onto a light detector, so the transmitted intensity can be measured at each analyser angle. With this Malus’s law apparatus, students verify that intensity varies as the square of the cosine of the angle between the two polarisation directions.

Malus’s Law and Polarised Light

Light is a transverse wave whose electric field oscillates across the direction of travel. A polariser passes only the component of the field along its transmission axis. If plane-polarised light meets an analyser whose axis is at an angle θ to the polarisation, the transmitted field is reduced by the factor cos θ, and since intensity depends on the square of the field, the transmitted intensity is I = I0 cos² θ. Turning the analyser through a full circle gives two maxima and two minima.

Why a Diode Laser Helps, and the Point to Watch

A diode laser gives a bright, narrow, single-colour beam that keeps the detector signal strong and makes alignment easy. However, the light from a laser diode is usually already partly polarised. Good technique is to turn the first polariser until it passes the most light from the laser, fix it there, and only then rotate the analyser. The laser should also be allowed to warm up so its output is steady during the readings.

Taking and Plotting the Readings

With the beam blocked, record the detector’s dark reading, which is subtracted from every other value. Then take readings at regular intervals of analyser angle, for example every 10 degrees through a full turn. A graph of intensity against angle shows the cos² shape, and a graph of intensity against cos² θ should be a straight line through the origin. A minimum that never reaches zero points to stray light or imperfect polarisers, while a flattened maximum can mean the detector is saturated. The components, laser output, detector and meter of this set can be confirmed at enquiry.

Experiments

  • Verifying Malus’s law quantitatively with a light detector
  • Plotting intensity against cos² θ to obtain a straight-line graph
  • Investigating the partial polarisation of the light from a laser diode
  • Measuring the extinction achieved by crossed polarisers

Specifications

Type Malus’s law experiment set with diode laser source
Typical layout Diode laser, polariser, rotatable analyser with angle scale, light detector
Measures Transmitted intensity against analyser angle
Relationship tested I = I0 cos² θ
Laser output, detector, meter and mounting Confirm at enquiry

Care & Handling

  • Never look into the laser beam or its reflections, and keep the beam below eye level.
  • Handle polarisers by their mounts and clean them only with lens tissue.
  • Reduce the laser intensity or move the detector if the reading stops rising at the maximum.
  • Switch off the laser and store the Malus’s law apparatus covered between sessions.

Why Choose LabEquip

Colleges buy a laser-based Malus’s law set when they want students to measure, not just observe, the cos² dependence of polarised light. LabEquip lists it with its physics lab equipment; the polarizer/analyzer pair suits qualitative demonstrations, and the He-Ne laser is an alternative source for wider optics work. Ask about components through the contact page.

Frequently Asked Questions

What does Malus’s law state?

When plane-polarised light passes through an analyser, the transmitted intensity equals the incident intensity multiplied by the square of the cosine of the angle between the polarisation direction and the analyser axis.

Why does the reading not fall exactly to zero when the polarisers are crossed?

Real polarisers are not perfect, and some stray room light reaches the detector. Dimming the room and subtracting the dark reading bring the minimum closer to zero.

Why measure a dark reading?

The detector gives a small reading even with the beam blocked, from stray light and its own offset. Subtracting this from every reading leaves only the light that came through the polarisers.

Is the light from a diode laser already polarised?

Usually it is partly polarised. That is why the first polariser is turned to pass the most laser light and then fixed, so that the analyser alone sets the angle in the experiment.

How should the results be plotted?

Plot intensity against the analyser angle to see the cos² curve, then plot intensity against cos² θ. A straight line through the origin confirms the law, and its gradient equals the maximum intensity.

Is a diode laser safe for students?

With supervision and simple rules it can be used safely: never look into the beam, keep it below eye level, remove reflective objects from its path and switch it off when not taking readings.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
INR Indian rupee
Product has been added to your cart
Compare (0)