Search

In Stock

YBCO Levitation Disk

Disque de lévitation YBCO, Optimized Transition Threshold (>90 K). Supports the Application of cryogenic handling techniques using standard liquid nitrogen, reducing the requirement for specialized liquid helium infrastructure.

Precision Surface Planarity Promotes Understanding of uniform magnetic field repulsion, ensuring repeatable data during electromagnetic force measurements.

₹2,130.00

Quick Answer: The YBCO levitation disk is a disk of yttrium barium copper oxide, a ceramic high-temperature superconductor. When cooled in liquid nitrogen it becomes superconducting, and a small magnet placed above the YBCO levitation disk floats in mid-air.

What Happens When the Disk Is Cooled

At room temperature YBCO conducts electricity like a poor metal, but below its critical temperature of roughly 90 K it becomes a superconductor. Liquid nitrogen boils at 77 K, so immersing the disk cools it well into the superconducting state. The disk then expels magnetic field from its interior, the Meissner effect, and a magnet resting above it is repelled and lifted into the air.

The floating magnet is also held in place sideways, which surprises most students. That stability comes from flux pinning: some of the field penetrates the disk in tiny flux tubes that become trapped at defects in the ceramic, so the magnet resists moving in any direction.

Running the Demonstration

Stand the disk in a shallow insulated dish, pour in liquid nitrogen until the disk is covered, and wait until the vigorous boiling settles, which shows the disk has reached the liquid’s temperature. Lower a small strong magnet onto it with non-magnetic tweezers; it should hover just above the surface. Spin the magnet gently and it keeps rotating with very little friction.

For a field-cooled version, rest the magnet on a thin non-magnetic spacer on the disk before adding the nitrogen, then slide the spacer out once the disk is cold. The magnet stays at the spacer’s height, showing that the field present during cooling has been pinned. Letting the nitrogen evaporate ends the demonstration: once the disk warms above its critical temperature the magnet settles onto it.

Lesson Uses

  • First demonstrations of superconductivity in school and college physics
  • Showing the Meissner effect and flux pinning side by side
  • Field-cooled levitation at a chosen height using a spacer
  • Science outreach and open-day displays

Specifications

Product YBCO superconductor disk for levitation demonstrations
Material Yttrium barium copper oxide ceramic, as listed in the product name
Coolant Liquid nitrogen
Phenomena shown Meissner effect, flux pinning, nearly frictionless rotation
Disk size and whether a magnet is included Confirm at enquiry

Care & Handling

  • Dry the disk thoroughly after each use; moisture and condensation gradually degrade YBCO
  • Store the disk in a sealed container with desiccant, away from water and acids
  • Handle it carefully, as the ceramic is brittle and chips if dropped or struck by the magnet
  • Wear insulated gloves and eye protection when pouring liquid nitrogen, and work in a ventilated room

Why Choose LabEquip

The YBCO levitation disk is the starting point for most superconductivity demonstrations in schools, colleges and outreach programmes. For stronger, load-bearing effects see the superconducting levitation kit; contact LabEquip to confirm the disk size and whether a magnet is included, or browse more physics lab equipment.

Frequently Asked Questions

Why does the YBCO disk need liquid nitrogen?

YBCO becomes superconducting only below its critical temperature of roughly 90 K. Liquid nitrogen, at 77 K, is the cheapest and most practical coolant that reaches that temperature.

Why does the magnet float without sliding off?

Flux pinning traps part of the magnetic field inside the disk at defects in the ceramic. The magnet is therefore held at a fixed position and resists sideways movement as well as vertical movement.

How long does the magnet keep floating?

While the disk stays cold. As the liquid nitrogen evaporates and the disk warms above its critical temperature, superconductivity is lost and the magnet comes to rest on the disk.

Can the disk be damaged by water?

Yes. YBCO reacts slowly with moisture, so condensation that forms as it warms should be dried off promptly and the disk stored dry between uses.

What is the difference between zero-field and field cooling?

In zero-field cooling the disk is cooled with no magnet nearby, so the magnet is then mainly repelled. In field cooling the magnet is held over the disk while it cools, and the pinned field keeps it at that height afterwards.

Is liquid nitrogen safe in a classroom?

With precautions: insulated gloves, eye protection, good ventilation and open insulated containers. Never seal liquid nitrogen in a closed vessel, and avoid skin contact, which causes cold burns.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top