Search

In Stock

Weight Set, 1mg-500g, Class F1

Austenitic Non-Magnetic Stainless Steel: Forged from high-density alloys with a magnetic susceptibility (χ) ≤ 0.05, preventing electromagnetic interference with sensitive laboratory load cells during critical calibration procedures.

Precision-Polished Monoblock Architecture: Features a high-gloss, low-porosity finish on all 1g-500g weights and standardized geometric fractional milligrams, designed to prevent microscopic particulate accumulation and ensure long-term mass stability.

$19.40

Quick Answer: The Weight Set, 1mg-500g, Class F1 is a cased set of calibration weights running from 1 mg to 500 g, titled in accuracy class F1. An F1 calibration weight set of this span lets one laboratory test precision balances up to 500 g and check an analytical balance at the loads it normally weighs.

How the Pieces of a 1 mg to 500 g Set Are Arranged

Sets covering a range like this are commonly built on a decade pattern of one, two, two and five, so that 1 mg, 2 mg, 2 mg and 5 mg are followed by 10 mg, 20 mg, 20 mg and 50 mg, and so on up to the largest piece. Where a value appears twice, one of the pair normally carries a small mark, such as a dot or a star, because each piece has its own calibration value and the two must not be confused.

The milligram pieces are usually not tiny cylinders, which would be impossible to handle, but thin sheets or short lengths of wire with one edge or end turned up for forceps. Their outline often indicates the value within each decade.

Testing Linearity With Combined Loads

A balance can read correctly at zero and at full load and still be wrong in between. A linearity test places known loads at several points across the range, for example near a quarter, a half and three quarters of capacity, and compares each reading with the sum of the conventional mass values of the pieces used. Because the set contains marked duplicates, the same test load can often be built in two ways, and agreement between the two readings supports both the pieces and the balance.

Where Class F1 Is Enough Over This Range

Permissible errors get smaller as the pieces get smaller, but far more slowly than the nominal values do, so for the smallest F1 pieces the tolerance is a sizeable fraction of the nominal mass. That is why the milligram pieces of an F1 set are used for low-load checks rather than as references on semi-micro balances. For top-pan precision balances, and for analytical balances checked at working loads of several grams, F1 sits comfortably inside the tolerances usually set.

Applications

  • Linearity and span checks on precision balances with capacities up to 500 g
  • Routine checks of an analytical balance at the sample loads it normally weighs
  • Calibrating F2 and M-class pieces against the F1 values by comparison
  • Metrology practicals on assembling test loads and combining the uncertainties of several pieces

Specifications

Nominal range 1 mg to 500 g, as titled
Accuracy class F1, as titled
Usual arrangement Decade sequence with marked duplicate pieces
Small pieces Milligram sheet or wire weights lifted with forceps
Role Working reference for balance linearity, span and routine checks
Piece list, material, case and calibration documents Confirm at enquiry

Care & Handling

  • Lift milligram sheets by their turned-up edge with smooth-tipped forceps, never with fingers.
  • Return each marked duplicate to its own marked cavity so certificate values stay with the right piece.
  • Write down exactly which pieces made up each combined load during a linearity test.
  • Keep the case shut between pieces and store it in the balance room, away from fumes and direct sun.

Why Choose LabEquip

Quality-control and teaching laboratories whose balances run from milligram samples up to a few hundred grams buy this F1 set as one working reference. LabEquip lists it in its Physics Equipments range; the Class E2 weight set over the same 1 mg to 500 g span suits finer balances, and the F2 version covers routine top-pan checks. Send your balance list through the contact page.

Frequently Asked Questions

Why does the set contain two weights of the same value?

So that every whole value in each decade can be made from as few pieces as possible. Pieces of one, two, two and five units add up to any value from one to ten, which keeps the number of pieces on the pan, and the combined uncertainty, low.

How are the two duplicate pieces told apart?

One piece of each pair normally carries a mark such as a dot or a star. The calibration documents list the marked and unmarked pieces separately, so they should always go back to their own cavities in the case.

Why are the milligram weights flat sheets or wires?

A solid weight of a few milligrams would be too small to pick up safely. Thin sheets or wires with a raised edge or end can be gripped with forceps, and their shape usually shows their value at a glance.

How do I run a linearity check with this set?

Zero the balance, then place loads at several points across its range, from near zero to near capacity. Compare each reading with the sum of the certificate values of the pieces used and note any deviation that exceeds your tolerance.

Is an F1 set suitable for a semi-micro balance?

Not as the main reference. The permissible errors of the smallest F1 pieces are large compared with the readability of a semi-micro balance, so an E2 or higher set is used there. The F1 set can still give a quick plausibility check at larger loads.

Can pieces be combined to make loads that are not in the set?

Yes. The conventional mass of a combination is the sum of the individual piece values. Each extra piece adds its own uncertainty, so build every load from the smallest number of pieces that gives the value needed.