Quick Answer: The Weight Set, 1g-2Kg, Class F2 is a set of weights with nominal values from 1 g to 2 kg, titled in accuracy class F2, a working class for routine balance checks. A Class F2 weight set is used to test precision and commercial balances in production, quality-control and teaching labs, and to calibrate M-class weights.
What F2 Is For
In the international classification of weights, F2 sits below E1, E2 and F1 and above the M classes used for everyday trade weights. Its permissible errors are wider than those of the classes above, which makes F2 weights robust and economical while still close enough to nominal for checking balances of the high accuracy class, the typical top-pan precision balance in a laboratory or factory. F2 weights are also the usual reference for calibrating M1 weights and for commercial weighing of valuable goods.
A sound rule when choosing a class is to compare the weight’s permissible error with the tolerance expected of the balance. If the weight’s error is no more than about a third of that tolerance, its contribution to the check is small enough to ignore. Where F2 errors pass that test, an F2 set does the job without the cost and handling demands of an E-class set.
Daily Checks and Repeatability
F2 sets are working sets, used every day rather than kept in reserve. A typical routine is a single-point check before use, with a weight near the load normally weighed, and a fuller check each week or month. Repeatability is part of the fuller check: the same weight is placed on the pan ten times, removed between readings while the balance returns to zero, and the standard deviation of the readings calculated. Repeatability that worsens over time often points to a draughty site, a vibrating bench or a developing fault in the balance.
Applications
- Routine checks of precision top-pan balances in production and quality-control labs
- Repeatability and span testing of commercial and laboratory scales
- Calibration of M-class weights by comparison
- Practical classes on weighing quality and balance checking
Specifications
| Nominal range | 1 g to 2 kg, as titled |
| Accuracy class | F2, as titled |
| Role | Working weights for balance checks and M-class calibration |
| Handling | Clean gloves or forceps; weight lifter for heavy pieces |
| Pieces included, material, case and calibration documents | Confirm at enquiry |
Care & Handling
- Use the Class F2 weight set with clean gloves or forceps, and set pieces down gently in the centre of the pan.
- Keep a log of checks so that drift in a balance, or damage to a weight, is noticed early.
- Return pieces to the case after each check and keep it in a clean, dry place.
- Have the set recalibrated at the interval your quality system sets, and sooner if pieces are dropped.
Why Choose LabEquip
Manufacturing plants, food and pharmaceutical quality labs and technical colleges buy F2 sets as everyday check weights for their precision balances. LabEquip lists this set in its Physics Equipments range; laboratories needing a higher class over the same range can see the Class E2 weight set, 1 g to 2 kg. Send your balance details through the contact page.
Frequently Asked Questions
How does Class F2 compare with Class E2?
Both are accuracy classes for weights, but E2 is two classes higher, with permissible errors roughly ten times smaller than F2 for the same nominal value. E2 suits analytical balances and calibrating other weights; F2 suits routine checks of precision balances.
Can an F2 set be used on an analytical balance?
For a rough check it can, but its permissible errors are too large compared with the readability of an analytical balance for calibration purposes. A higher class, E2 or F1, is the usual choice there.
How do I run a repeatability test?
Place the same weight on the pan, read it, remove it and let the balance return to zero. Repeat ten times and calculate the standard deviation of the readings. A small standard deviation means the balance gives consistent results.
Why compare the weight error with the balance tolerance?
A check is meaningful only if the weight’s own error is small compared with what is being tested. Keeping it to about a third of the balance tolerance or less means any significant deviation can be blamed on the balance, not the weight.
What are M-class weights?
They are the lower accuracy classes, M1 and below, used for trade weighing and general industrial purposes. F2 weights are commonly used as the references when M-class weights are calibrated.
Should an F2 set be kept apart from everyday weights?
Yes. Even as a working set, it should be used only for checks and calibrations, not as general loads, so that its values stay known. Mixing it with school or trade weights invites damage and confusion.