Search

In Stock

Weight, 10Kg, Class F1

Non-Magnetic Austenitic Stainless Steel: Forged from high-grade alloys with a magnetic susceptibility (χ) below 0.05, preventing measurement errors caused by electromagnetic interference in sensitive industrial weighing environments.

Sub-Micrometer Mirror Finish: Features a precision-polished surface to mitigate particulate accumulation and atmospheric oxidation, integrated with a secure internal adjustment cavity for exact mass regulation during long-term duty cycles.

$24.93

Quick Answer: The Weight, 10Kg, Class F1 is a single 10 kg reference weight titled in accuracy class F1. A 10 kg F1 weight is used to test high-capacity precision balances and bench scales and serves as the reference when lower-class 10 kg weights are calibrated by comparison.

Calibrating Other Weights by Comparison

In a calibration room the F1 weight acts as reference A when the conventional mass of a test weight B, such as a 10 kg working weight used on a factory floor, has to be found. The two are weighed alternately in the order A, B, B, A on a mass comparator or a suitable balance. Taking the mean of the two A readings and the mean of the two B readings cancels any steady drift of the instrument during the cycle, and the difference between those means is added to the certificate value of A to give the value of B.

Several ABBA cycles are run and averaged, which reduces random scatter. Because the two weights are almost equal, errors in the balance’s span and linearity largely cancel, so a comparison can give a better result than reading the test weight directly.

Shapes Used for Large Weights

Weights of 10 kg are made in two common forms: a cylinder with a lifting knob, typical of the higher accuracy classes, and a rectangular block with a handle, which stacks well and is often used for heavier test loads. Many large weights also have a sealed adjusting cavity in which small amounts of material were added or removed during adjustment. The form, material and finish of this 10 kg F1 weight should be confirmed at enquiry.

Placing the Weight on a Balance

Lower the weight vertically onto the centre of the pan rather than sliding it, using both hands or a lifting tool and clean gloves. Off-centre placement brings in eccentric-load error, and a weight that is set down hard can upset the balance and nick its own base.

Applications

  • Span and repeatability tests on precision balances whose capacity reaches 10 kg or more
  • Reference weight for calibrating M-class 10 kg working weights by ABBA comparison
  • Checks on formulation balances in pharmaceutical, paint and food production
  • Practical training in mass comparison in metrology and instrumentation courses

Specifications

Nominal value 10 kg, as titled
Accuracy class F1, as titled
Supplied as Single individual weight
Typical role Reference for comparison and for tests of high-capacity balances
Shape, material, adjusting cavity and calibration documents Confirm at enquiry

Care & Handling

  • Handle the 10 kg F1 weight with clean gloves and never let it slide across a pan or bench.
  • Keep it in the balance room, covered, so it stays clean and at room temperature.
  • Leave the seal of any adjusting cavity untouched; a disturbed seal means the weight needs recalibration.
  • Record each use in the reference-weight log together with the balance it was used on.

Why Choose LabEquip

Calibration rooms, pharmaceutical plants and university metrology labs buy a single F1 10 kg weight when they need a dependable reference at that load. LabEquip lists it in its Physics Equipments range; the Class F2 10 kg weight is the working counterpart for everyday scale checks. Discuss shape and documentation through the contact page.

Frequently Asked Questions

What is an ABBA weighing cycle?

It is a comparison sequence in which the reference A and the test weight B are placed on the balance in the order A, B, B, A. Averaging the two readings of each weight cancels steady drift, and their difference gives the value of B relative to A.

Why do calibration labs repeat the cycle several times?

Each cycle is affected by small random effects such as air currents and vibration. Repeating it and averaging the differences reduces that scatter and gives a standard deviation that feeds into the uncertainty of the result.

Why is comparison more accurate than weighing the test weight directly?

When two nearly equal masses are compared, errors in the balance span and linearity affect both readings almost equally and cancel in the difference. Only the balance repeatability and the reference value remain important.

Can a 10 kg F1 weight check a scale that reads in coarse steps?

It can, but F1 is more accurate than such a check needs. For scales with coarse intervals an F2 or M1 weight is normally sufficient, provided its permissible error is small compared with the scale interval.

What is the adjusting cavity in a large weight?

It is a sealed hollow, usually under a screw plug or cap, into which material was added or removed to bring the weight to its nominal value. The seal shows that the adjustment has not been disturbed since calibration.

How should a 10 kg reference weight be stored?

Upright on a clean shelf at a convenient lifting height, in its case or under a cover, in the same room as the balances it serves. A low shelf reduces the risk of dropping it during handling.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
USD United States (US) dollar
Product has been added to your cart
Compare (0)