Precision Torsion-Free Suspension: Features a height-adjustable vertical glass tube housing a zero-torsion suspension fiber and a balanced brass stirrup, designed to facilitate frictionless horizontal oscillations for high-accuracy oscillation period (T) calculations.

Parallax-Corrected Observation Chamber: Constructed from a stabilized, non-magnetic enclosure with a mirrored base and high-transmittance glass apertures, enabling the precise alignment of the magnetic axis with integrated scales to eliminate visual measurement errors.

$12.69

Quick Answer: The Vibration Magnetometer is a draught-proof box in which a bar magnet hangs from a fine fibre and oscillates in the Earth’s magnetic field. Timing the oscillations lets students compare the magnetic moments of two magnets and, together with a deflection magnetometer, find the horizontal component of the Earth’s field.

Principle of the Oscillation Method

A magnet free to turn in a horizontal plane settles along the magnetic meridian. Turned slightly aside and released, it swings back and forth about that line, because the Earth’s horizontal field exerts a restoring couple on it. For small swings the motion is simple harmonic, and its time period is two pi times the square root of I divided by (M times BH), where I is the moment of inertia of the magnet about the suspension, M its magnetic moment and BH the horizontal component of the Earth’s field.

The instrument provides the conditions this formula needs. The magnet rests in a light stirrup hung from an unspun silk fibre, so the fibre exerts almost no twisting force, and the glass-sided box shields the swinging magnet from air currents. A reference line or mirror strip on the base lets the observer count each swing as the magnet passes the same point.

Specifications

Type Oscillation (vibration) magnetometer
Suspension Magnet in a stirrup hung from a fine fibre
Enclosure Box with glass sides to exclude draughts
Measured quantity Time period of small oscillations
Box material, levelling screws and magnets supplied Confirm at enquiry

Getting Reliable Periods

Before any timing, the twist must be taken out of the fibre. A non-magnetic brass bar of similar mass is hung in the stirrup and left to come to rest, then replaced by the magnet; otherwise the fibre adds its own restoring couple and shortens the period.

Keep the amplitude small, a few degrees on either side, and time twenty or more complete oscillations with a digital stopwatch, repeating each measurement. Iron objects, steel furniture and other magnets must be kept well away from the box, because any extra field changes the period.

Experiments Performed

  • Comparing the magnetic moments of two bar magnets by the sum and difference method
  • Finding the horizontal component of the Earth’s field when combined with a deflection magnetometer
  • Comparing the horizontal field at two places, for example inside and outside a building
  • Studying simple harmonic motion with a magnetic restoring couple

Care & Handling

  • Hang the stirrup and magnet gently; a jerk can break the fine fibre.
  • Keep spare fibre in the box and store the instrument away from magnets and steel cupboards.
  • Level the box using its base before timing so that the stirrup hangs clear of the walls.
  • Clean the glass sides with a dry cloth so the reference line stays easy to see.

Why Choose LabEquip

Colleges and senior physics laboratories buy the vibration magnetometer together with a deflection magnetometer, since the two instruments are used side by side to find the Earth’s horizontal field. LabEquip lists both in its physics equipment category; for fibres, magnets and class quantities, our team is reached through the contact page.

Frequently Asked Questions

How does a vibration magnetometer compare two magnetic moments?

In the sum and difference method the two magnets are placed together in the stirrup, first with like poles together and then with unlike poles together, and the two periods are timed. The ratio of the moments follows from the squares of those periods.

How is the Earth’s horizontal field found with this instrument?

The vibration magnetometer gives the product of the magnetic moment and the horizontal field, while a deflection magnetometer gives their ratio. Dividing the product by the ratio and taking the square root gives the horizontal field.

Why is an unspun silk fibre used for the suspension?

Unspun silk is strong but very easy to twist, so it exerts almost no restoring couple of its own. The swinging of the magnet is then controlled by the magnetic field alone, as the formula assumes.

Why must the amplitude of oscillation be small?

The formula for the period is exact only for small swings, where the restoring couple is proportional to the angle. Large swings lengthen the period slightly and make the timing less reliable.

How is the moment of inertia of the magnet found?

For a rectangular bar magnet it is the mass times the sum of the squares of its length and breadth, divided by twelve. Measure the mass on a balance and the dimensions with vernier calipers.

What disturbs the readings during timing?

Nearby iron and steel, other magnets, electric currents in cables, air draughts and a twisted fibre. Work on a wooden table away from metal furniture and keep spare magnets at a distance during timing.