Quick Answer: The Vernier Microscope (Six Position Microscope) is a travelling microscope: a low-power microscope that slides along a graduated scale fitted with a vernier, so the distance it moves between two cross-wire settings can be read accurately. The vernier microscope is used to measure small lengths such as the bore of a capillary tube, the thickness of a glass slab and real and apparent depth.
Measuring with Cross-Wires and a Vernier
Every reading combines the main scale and the vernier. The least count is the value of one main-scale division minus the value of one vernier division, and the instrument’s own markings give it. To measure a length, set the cross-wire on one edge of the object and read the scales, wind the microscope across to the other edge and read again; the difference is the length. Approach every setting from the same direction, because reversing the screw introduces backlash error.
Two practicals use the microscope most. For refractive index by real and apparent depth, focus on a mark on the base, place the glass slab over it and refocus on the image of the mark, then focus on a few powder grains sprinkled on top of the slab; real thickness divided by apparent thickness gives the refractive index. For capillary rise, the tube is clamped horizontally and the bore is measured across two perpendicular diameters at its cut end.
The title names the instrument a six position microscope. Travelling microscopes are commonly set with the tube vertical for depth readings or horizontal for bores, and the positions available on this model should be confirmed when ordering. The Newton’s ring experiment microscope is arranged for looking down on interference rings, and the college pattern telescope reads scales at a distance rather than close up.
Experiments
- Refractive index of a glass slab by real and apparent depth
- Radius of a capillary bore for surface tension by capillary rise
- Diameters of Newton’s rings
- Thickness of thin plates and widths of small gaps
Specifications
| Type | Travelling (vernier) microscope |
| Reading | Main scale with vernier; least count as marked on the instrument |
| Setting | Cross-wire in the eyepiece |
| Experiments | Capillary bore, real and apparent depth, Newton’s rings, slab thickness |
| Six-position arrangement, travel and magnification | Confirm at enquiry |
Care & Handling
- Move the carriage with its screw and lock it lightly; never push the tube along by hand.
- Keep the scale and vernier clean and dry, and do not rub across the graduations.
- Clean the eyepiece and objective with lens tissue only.
- Cover the microscope after use and store it in a dry place.
Why Choose LabEquip
Undergraduate laboratories and senior secondary schools with capillary-rise and refractive-index practicals keep several vernier microscopes so groups can work in parallel. LabEquip lists this one with its physics lab equipment; write to us through the contact page for station sets.
Frequently Asked Questions
How do I find the least count of the vernier microscope?
Divide the value of one main-scale division by the number of vernier divisions, or subtract the value of one vernier division from one main-scale division. Both give the smallest length the instrument can read.
What is backlash error and how do I avoid it?
Backlash is the slack in the screw that moves the carriage, which makes a reading depend on the direction of turning. Approach every setting from the same side and never reverse direction during a series.
How is refractive index found by real and apparent depth?
Focus on a mark, place the glass slab over it and refocus on its image, then focus on powder grains on the top surface. Refractive index equals real thickness divided by apparent thickness, both found from the three readings.
How is the bore of a capillary tube measured?
Clamp the tube horizontally with its cut end facing the microscope, set the cross-wire on opposite edges of the bore and take the difference. Repeat across a perpendicular diameter and average, since bores are seldom perfectly round.
What does six position mean?
It is the name under which this pattern is listed. Travelling microscopes are usually set with the tube vertical for depth readings or horizontal for capillary bores; confirm how this model’s positions are arranged when you enquire.
How does it differ from a reading telescope?
The microscope works close to the object and measures by moving along its own scale, so it suits very small lengths. A reading telescope stays put and reads a more distant scale through its optics.