Search

In Stock

Pressure Sensor

Sonde de pression, Linear Graduated Insertion Stem Enables precise Analysis of the mathematical relationship between fluid depth, density, and pressure magnitude (Pascal’s Law).

Pour manomètre à eau ou électronique, High-Sensitivity Synthetic Membrane Supports the Application of evidentiary-grade data acquisition when coupled with manometric capsules or U-tube manometers for advanced fluid mechanics modules.

Standardized Serrated Hose Interface Rotation de la capsule sans se mouiller les doigts, Ensures seamless Synthesis of complex pneumatic and hydraulic experimental setups, maintaining airtight integrity during high-cadence laboratory rotations.

₹1,350.00

Quick Answer: The pressure sensor is an electronic probe that converts the pressure at its inlet into a signal that a data logger or interface can record. In physics practicals the pressure sensor gives continuous readings for gas-law and liquid-pressure work in place of a dial gauge or manometer.

How Pressure Becomes a Signal

Most educational pressure sensors use a thin diaphragm carrying strain-sensitive resistors. Pressure bends the diaphragm, the resistances change, and the electronics turn that change into a voltage that the logger scales into kilopascals. Because the reading is recorded many times a second, students can watch a pressure change as it happens and plot it straight away.

Sensors come in two kinds. An absolute sensor has a sealed vacuum behind its diaphragm and reads about 100 kPa in room air. A relative, or gauge, sensor has the other side open to the atmosphere and reads zero in room air, so atmospheric pressure has to be added before using the value in a gas-law calculation. Which kind this sensor is, its range and its connector are confirmed at enquiry.

Experiments with Logged Pressure

For Boyle’s law a syringe is connected to the inlet, the plunger is moved in steps and pressure is logged at each volume; a graph of p against 1/V is a straight line. The air in the connecting tube belongs to the trapped gas too, so keep the tube short or add its volume to each syringe reading.

For the pressure law a flask of air is sealed to the sensor and warmed in a water bath alongside a thermometer. Extending the straight p against temperature line back to zero pressure brings it close to minus 273 degrees Celsius, the idea behind the absolute temperature scale. Through a membrane capsule the same sensor also records pressure against depth in water.

Specifications

Product Electronic pressure sensor for data logging
Usual sensing element Diaphragm with strain-sensitive resistors
Output Signal for a data logger or interface
Typical uses Gas laws, pressure in liquids, pressure changes in reactions
Range, absolute or relative reading, and interface Confirm at enquiry

Applications

  • Boyle’s law: pressure against volume of air trapped in a syringe
  • Pressure law: pressure against temperature for a sealed flask of air
  • Pressure against depth in water through a membrane capsule
  • Following gas build-up in a small reaction vessel

Care & Handling

  • Keep liquid out of the sensor port; for liquid work connect through a capsule or a tube with an air gap
  • Stay within the sensor’s rated pressure, even briefly when pushing a syringe hard
  • Release the pressure before disconnecting any tubing
  • Store with the port capped and the cable loosely coiled

Why Choose LabEquip

Schools moving gas-law and fluids practicals onto data loggers need a sensor that gives continuous, graphable readings without a liquid manometer. Combine it with a 3-way valve to set starting conditions and a pressure capsule for liquids; contact LabEquip to match it to your interface, or browse more physics lab equipment.

Frequently Asked Questions

What is the difference between an absolute and a relative pressure sensor?

An absolute sensor measures against a sealed vacuum and reads about 100 kPa in room air. A relative sensor measures against the atmosphere and reads zero in room air, so atmospheric pressure must be added for gas-law calculations.

How do I estimate absolute zero with the sensor?

Seal air in a flask connected to the sensor, warm it in a water bath and record pressure against temperature. Extend the straight line back to zero pressure; it meets the temperature axis close to minus 273 degrees Celsius.

Why does the volume of the connecting tube matter?

The air in the tube and sensor body is part of the trapped gas but does not show on the syringe scale. Keep the tube short, or add its estimated volume to every syringe reading, otherwise pV will not stay constant.

Can the sensor measure water pressure directly?

Connect it through a tube ending in a membrane capsule, so that only air reaches the sensor while the capsule senses the liquid. Water entering a port designed for gas can damage the sensing element.

Why should a reaction vessel not stay sealed for long?

Gas produced by a reaction keeps raising the pressure and can push the stopper out or burst the vessel. Use small quantities, stop the run well within the sensor range and release the pressure promptly.

Which data logger does the sensor work with?

The connector and compatible interfaces can be confirmed at enquiry along with the pressure range. Tell us which logging system the school already uses so the sensor can be matched to it.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
INR Indian rupee
Product has been added to your cart