Pressure Gauge with Needle

Manomètre élève à aiguille -1 à +3 bars Raccord olive adaptable sur vos tuyaux souples, utilise a factory-calibrated copper alloy Bourdon tube for high-linear response across both positive pressure (+3 bar) and vacuum (-1 bar) gradients.

Integrated Zero-Point Adjustment: Features a ruggedized external screw for manual tare calibration, ensuring laboratory parity and measurement accuracy across varied atmospheric conditions.

$7.33

Quick Answer: The needle pressure gauge is an analogue dial instrument in which a pointer swings across a printed scale as the pressure in the connected tubing changes. In physics practicals the needle pressure gauge reads gas pressure in syringes, bottles and pumps for gas-law and air-pressure experiments.

Inside the Dial

Most dial gauges work on the Bourdon tube principle. A curved metal tube with a flattened cross-section is sealed at one end and connected to the pressure at the other. Raising the pressure inside makes the tube try to straighten, and the small movement of its free end is magnified by a lever and a toothed sector that turns the needle. Nothing electrical is involved, so the gauge works anywhere.

A dial gauge shows gauge pressure: the difference between the pressure in the tubing and the atmosphere outside. That is why the needle rests on zero when the gauge is open to the room, although the air around it is at roughly 100 kPa. For gas-law calculations atmospheric pressure is added to the reading; a gauge reading of 50 kPa corresponds to an absolute pressure of about 150 kPa.

Connecting and Reading the Gauge

Push the connecting tube firmly onto the inlet and check for leaks by closing the system and watching that the needle holds steady. Read the dial face-on so that the needle and its reflection or shadow do not mislead the eye, and give the glass a light tap before each reading so that friction in the linkage does not leave the pointer a little behind the true value.

Note the scale divisions printed on the dial before starting, and keep pressures within the marked range. A freshly compressed gas is warm, and its pressure drifts down as it cools, so wait for the needle to settle before recording.

Applications

  • Boyle’s law with a sealed syringe or air column, after converting to absolute pressure
  • Showing the pressure rise as a hand pump charges a bottle
  • Following the pressure increase when a sealed flask of air is warmed
  • Checking the supply pressure to a pneumatic or fluids demonstration

Specifications

Product Analogue pressure gauge with needle pointer
Reading Gauge pressure, relative to the surrounding atmosphere
Usual mechanism Bourdon tube with lever and pointer linkage
Connection By tubing to the gas volume being measured
Range, units and inlet size Confirm at enquiry

Care & Handling

  • Never exceed the highest pressure marked on the dial
  • Release pressure slowly so the needle does not slam back against the stop
  • Keep liquids out of the inlet unless the gauge is intended for them
  • Store the gauge face-up in its box, away from knocks that could bend the pointer

Why Choose LabEquip

Teachers running gas-law practicals want a gauge students can read at a glance across the bench, and a needle dial suits that well. Pair it with a 3-way valve to vent the circuit to zero between runs; contact LabEquip for the dial range, or see more physics lab equipment.

Frequently Asked Questions

Why does the gauge read zero when nothing is connected?

Because it measures gauge pressure, the difference from the surrounding atmosphere. Open to the air, the pressures inside and outside are equal, so the needle rests on zero even though the air itself is at roughly 100 kPa.

How do I convert a gauge reading for a gas law calculation?

Add atmospheric pressure. A gauge reading of 50 kPa means an absolute pressure of about 150 kPa, and it is the absolute value that goes into pV = constant or p/T = constant.

Why should I tap the dial before reading?

The pointer linkage has a little friction, so the needle can stick slightly behind the true value. A light tap with a finger lets it settle; a hard knock can damage the movement.

What is a Bourdon tube?

A curved, flattened metal tube sealed at one end. Pressure inside makes it try to straighten, and that small movement is magnified by levers and a gear to turn the needle across the dial.

Why does the reading drift during an experiment?

Usually because of temperature. A gas that has just been compressed is warm, and as it cools to room temperature its pressure falls. Wait for the needle to settle, and look for a leak if it keeps falling.

What range does the gauge cover?

The scale range and units are printed on the dial and can be confirmed at enquiry. Choose a range somewhat above the highest pressure the experiment will reach, so the needle works in the readable part of the scale.