Search

In Stock

Lee’s And Charlton’s Apparatus

High-Thermal-Mass Brass Disc: Engineered with a precision-machined, high-density metallic slab and integrated steam chamber, ensuring uniform heat distribution and stable temperature gradients for accurate thermal conductivity (k) calculations.

Low-Loss Radial Suspension: Features a specialized three-point suspension system designed to minimize conductive heat loss to the environment, allowing for high-fidelity measurements of axial heat flux through the specimen material.

$8.97

Quick Answer: Lee’s and Charlton’s apparatus measures the thermal conductivity of a poor conductor, such as cardboard, glass or ebonite, made into a thin disc. The specimen is sandwiched between a steam chamber and a metal disc, and the conductivity is found from the steady temperatures and the rate at which the metal disc cools.

Principle of the Disc Method

Lee’s and Charlton’s apparatus works on the disc method used for bad conductors. Heat from a steam chamber flows down through the thin specimen into a thick metal disc below it, and the metal disc loses that heat to the room from its surfaces. After some time the temperatures stop changing: the upper face of the specimen sits at the steam chamber temperature and the lower face at the temperature of the metal disc. At this steady state, the heat conducted through the specimen each second equals the heat the metal disc loses each second.

The conducted heat depends on the conductivity, the area of the specimen and the temperature difference across it, divided by its thickness. The heat lost by the metal disc is found separately, from its mass, its specific heat capacity and its rate of cooling at the steady temperature. Equating the two gives the thermal conductivity.

Specifications

Type Disc method apparatus for thermal conductivity of bad conductors
Main parts Steam chamber, metal disc with thermometer hole, specimen disc, suspension stand
Heating Steam passed through the upper chamber
Readings taken Two steady temperatures, specimen thickness and radius, cooling curve of the metal disc
Specimens and thermometers supplied Confirm at enquiry

Taking the Readings

Thermometers placed in the holes of the steam chamber and the metal disc are read every few minutes until both readings stay the same; these are the two steady temperatures. The specimen thickness is measured at several points with a screw gauge, and its radius with vernier calipers.

Next the specimen is removed and the metal disc is heated directly against the steam chamber until it is a few degrees above its steady temperature. The steam chamber is lifted away, the specimen is laid on top of the metal disc again, and the disc’s temperature is recorded at regular intervals as it cools. A graph of temperature against time gives the rate of cooling as the slope of the tangent drawn at the steady temperature.

Specimens and Practicals

  • Determining the thermal conductivity of cardboard, glass, ebonite or wood by the disc method
  • Plotting a cooling curve and finding a rate of cooling from the slope of a tangent
  • Comparing insulating materials used in buildings and cookware
  • Undergraduate heat practicals that combine steady-state and cooling measurements

Care & Handling

  • Keep the faces of the steam chamber, specimen and metal disc clean and flat so that thermal contact is good.
  • Drain the steam chamber after use and dry it to prevent internal corrosion.
  • Handle the steam chamber and metal disc by their supports only; both stay hot for a long time.
  • Store specimen discs flat, because a warped disc leaves an air gap that spoils the steady temperatures.

Why Choose LabEquip

College and senior-school physics laboratories buy Lee’s and Charlton’s apparatus for the bad-conductor experiment in their heat syllabus. For a simpler classroom comparison of how fast different metals conduct, LabEquip also offers a heat conductivity apparatus, while the disc apparatus itself is listed in our physics equipment category. Our team can be reached through the contact page about specimens and class quantities.

Frequently Asked Questions

Why is the specimen made as a thin, wide disc?

A poor conductor passes very little heat, so the specimen is made wide to give a large area and thin to give a short path. Together these allow enough heat to flow for the temperatures to be measured, and the steady state is reached in a reasonable time.

Why is a cooling curve needed in Lee’s method?

At the steady state the metal disc loses heat at the same rate as heat is conducted to it. That rate cannot be read directly, so the disc is later allowed to cool on its own and its rate of cooling at the steady temperature is taken from the graph.

Which materials can be tested with this apparatus?

Bad conductors that can be cut into a flat disc of the same diameter as the metal disc, such as cardboard, ebonite, glass, plywood or rubber sheet. The faces must be flat so they make good contact.

What formula gives the conductivity in Lee’s method?

In its simple form, conductivity equals the mass of the metal disc times its specific heat times its rate of cooling times the specimen thickness, divided by the specimen area times the temperature difference. A refined version corrects for heat lost from the curved edge.

Why does the experiment take so long?

The specimen conducts slowly and the metal disc has a large heat capacity, so many minutes pass before both temperatures stop changing. Starting steam early and reading the thermometers at fixed intervals keeps the session on track.

Can this apparatus measure the conductivity of a metal?

No. A metal disc would conduct so well that the temperature difference across it would be too small to measure. Good conductors are measured with a long bar method, such as Searle’s apparatus, instead.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
USD United States (US) dollar
Product has been added to your cart
Compare (0)