Integrated Low-Voltage Optical Module: Features a high-intensity, focused light source housed in a ventilated, light-tight metallic enclosure with a precision-ground condensing lens for sharp, high-contrast image projection.

Translucent Millimetric Metrology Plate: Equipped with a linear scale graduated in 1mm subdivisions on a frosted substrate, mounted on a dual-track adjustable frame to ensure parallax-free readings and precise zero-point calibration.

$13.99

Quick Answer: The Lamp & Scale is a reading arrangement for mirror instruments: a lamp sends a narrow beam carrying a fine line image onto the small mirror of a galvanometer or torsion apparatus, and the reflected spot falls on a graduated scale. A lamp and scale turns a tiny rotation of the mirror into a large, easily read movement of the light spot.

Doubling the Angle With a Mirror

When a mirror turns through an angle θ, the beam reflected from it turns through 2θ, because both the angle of incidence and the angle of reflection change by θ. On a scale at a distance D from the mirror, the spot therefore moves a distance d of about 2Dθ for small angles. Rearranged, θ = d/2D: a deflection of a few centimetres on a scale placed a good distance away corresponds to a very small rotation of the instrument’s coil or suspension.

The longer the distance to the scale, the larger the movement for the same rotation, which is why mirror instruments read this way can detect currents or twists far too small to move a pointer visibly.

Setting Up the Lamp and Scale

Place the arrangement at a measured distance in front of the instrument, with the scale square to the line joining it to the mirror. Adjust the lamp and its lens until a sharp image of the line or cross-wire falls on the scale, then set the instrument so that the spot rests at the zero or centre mark. A darkened room makes the spot easy to read, and a firm bench keeps it steady. The lamp rating, scale length and graduation, and stand of this model can be confirmed at enquiry.

Where It Is Used

The arrangement is the classic way of reading a ballistic galvanometer, where the first throw of the spot measures a pulse of charge, and of other mirror galvanometers used as sensitive current detectors. It is also used with torsion experiments, such as the static method for the modulus of rigidity, and with mirror magnetometers. Instruments such as the spot reflecting galvanometer build the lamp and its scale into their own case; this separate unit serves instruments that do not.

Applications

  • Reading the first throw of a ballistic galvanometer in charge and capacitance experiments
  • Detecting very small currents with a mirror galvanometer
  • Measuring small twists in static torsion experiments
  • Reading deflections of mirror magnetometers

Specifications

Type Lamp and scale reading arrangement
Principle Optical lever: the reflected beam turns through twice the mirror angle
Used with Mirror and ballistic galvanometers, torsion and magnetometer apparatus
Output Light spot or line image on a graduated scale
Lamp rating, scale length and graduation, stand Confirm at enquiry

Care & Handling

  • Let the lamp cool before adjusting or packing away the lamp and scale.
  • Keep the scale clean and flat; a warped or marked scale is hard to read accurately.
  • Inspect the power lead before use and route it where it cannot be caught.
  • Re-measure the mirror-to-scale distance whenever the arrangement is moved.

Why Choose LabEquip

College physics departments buy this reading unit to get full sensitivity from their mirror galvanometers and torsion apparatus. LabEquip lists it with its physics lab equipment. Share the instruments you will use it with through the contact page.

Frequently Asked Questions

Why does the spot move through twice the mirror’s angle?

Turning the mirror by an angle changes both the angle of incidence and the angle of reflection by that amount, so the reflected beam turns through twice the angle.

How far should the scale be from the mirror?

Far enough to give a large, readable deflection, but not so far that the spot becomes dim or blurred. Whatever distance is chosen must be measured accurately, because it enters every calculation.

How do I get a sharp line image on the scale?

Move the lamp or adjust its lens until the image of the line or cross-wire is focused on the scale. A sharp image lets the spot position be read to a fraction of a division.

Should I use a lamp and scale or a telescope and scale?

The lamp method lets several people see the spot at once and is quick to read, but needs a darkened room. A telescope and scale works in normal light and can be read very precisely, but only by one observer at a time.

How is the scale deflection converted to an angle?

For small deflections the rotation of the mirror in radians equals the deflection divided by twice the mirror-to-scale distance. For larger deflections, half the angle whose tangent is the deflection divided by the distance is used.

Why is a ballistic galvanometer read with a light spot?

The spot shows the first throw clearly and quickly, and the long optical lever makes small throws large enough to measure, so small quantities of charge can be determined.