Infrared Moisture Balance

250W Infrared Radiant Heat Source: Utilizes a high-efficiency IR lamp to achieve rapid, uniform thermal distribution across the sample tray, ensuring complete dehydration without carbonization for precise moisture percentage determination.

Integrated Torsion Wire Metrology: Features a high-sensitivity balance mechanism calibrated for forensic-grade mass determination, enabling direct percentage moisture readouts with 0.1% accuracy thresholds across diverse industrial sample types.

₹1,580.00

Quick Answer: The Infrared Moisture Balance is a weighing instrument with a built-in infrared heater that dries a sample on its pan while recording the falling mass, then reports moisture content from the mass lost. Laboratories use an infrared moisture balance for quick loss-on-drying checks on foods, grains, soils, powders and plastics.

A Balance That Watches the Sample Dry

The weighing cell is the heart of the instrument. The balance first records the wet mass of a thin layer of sample, the infrared source then heats it, and the balance keeps logging mass as moisture leaves. Plotted against time, those readings form a drying curve: a steep early fall while surface water evaporates, then a slower tail as water diffuses out from inside the particles, levelling off as the sample approaches dryness.

Because the result is calculated from two masses, the resolution and stability of the balance matter as much as the heater. Hot air rising off the pan pushes slightly on it, and these instruments are designed to keep that effect small; draughts from fans, air-conditioning vents or open windows still disturb readings and should be avoided.

Choosing the End Point

The instrument has to decide when drying is finished. A timed end point stops after a fixed period, which suits routine checks on one familiar material. An automatic end point stops once the mass loss per unit time falls below a set level, so wetter samples are simply dried for longer. For a new material, settings are worked out against an established drying-oven procedure, changing temperature and stop criterion until the infrared figure matches it.

Materials Tested

  • Moisture checks on grain, flour, spices and animal feed before storage or milling
  • Loss-on-drying tests on pharmaceutical powders, granules and excipients
  • Water content of soil, sand and building materials in environmental and civil-engineering labs
  • Drying checks on plastic granules before moulding
  • College practicals on gravimetric analysis and drying kinetics

Specifications

Measuring principle Thermogravimetric loss on drying
Heating Infrared source above the sample pan
Weighing Built-in balance logging mass during drying
Result Moisture content from initial and final mass
Capacity, readability, temperature range and end-point modes Confirm at enquiry

Care & Handling

  • Let the infrared moisture balance warm up on a stable, draught-free bench away from fans and vents.
  • Spread samples thinly and evenly on a clean pan, and never touch the pan or heater while they are hot.
  • Clean spills from the weighing chamber only after the instrument has cooled, and keep flammable solvents away from the heater.
  • Check the balance with a known weight at regular intervals, since every result depends on accurate mass readings.

Why Choose LabEquip

Food and grain processors, pharmacy and agriculture colleges, and soil-testing labs buy moisture balances to replace slower oven routines with quick, repeatable checks. LabEquip lists this model in its Physics Equipments range; for another design, see the digital infrared moisture system. Sample types and the number of tests you run can be discussed through the contact page.

Frequently Asked Questions

How is moisture content calculated?

From the initial wet mass and the final dry mass: the moisture percentage equals the mass lost divided by the initial mass, multiplied by 100. Many instruments can also show the dry content or the ratio of water to dry solid.

Does the result measure only water?

No. Loss on drying counts everything that evaporates at the chosen temperature, including alcohols, light oils and other volatile substances. Where only water is wanted, a water-specific method such as Karl Fischer titration is used for comparison.

Why spread the sample thinly?

A thin, even layer heats uniformly and lets moisture escape from all of it. A heap dries on top and stays wet underneath, and its surface can scorch before the inside is dry, so the result is both slow and wrong.

What drying temperature should be used?

It depends on the material. The temperature must be high enough to drive off water in a reasonable time but low enough that the sample does not decompose, melt or burn. Methods for each product are set up by comparison with an oven reference.

How often should the balance be checked?

Check the weighing function with a known weight regularly and whenever the instrument is moved. Many users also run a reference material of known moisture to confirm that the heater and end point give the expected result.

How does an infrared moisture balance compare with a drying oven?

An oven can dry many samples at once but takes much longer and needs separate weighings before and after. The infrared moisture balance handles one sample at a time and gives the answer in the same session, which suits frequent production checks.