Search

In Stock

Leclanche Cell Working Model

Original price was: ₹1,140.00.Current price is: ₹560.00.

The Leclanche Cell Working Model is an educational electrochemical-cell apparatus used for demonstrating how a primary cell converts chemical energy into electrical energy. It is intended for schools, colleges, physics laboratories and science teaching environments where students need a practical demonstration of cell construction, electrode action and external current flow.

Product Description

The STEMAids Leclanche Cell Working Model is designed for classroom and laboratory study of the operating principle of the Leclanché primary cell. A conventional Leclanché cell uses electrochemical reactions between its electrodes and electrolyte to generate direct current, making the apparatus useful for explaining the fundamentals behind early battery technology.

The model supports hands-on instruction in electrochemistry, electric cells and energy conversion. Exact construction material, dimensions, supplied electrodes, electrolyte, porous-pot configuration and nominal output of this STEMAids model should be confirmed before they are included in a procurement specification. Related apparatus can be explored under Physics Lab Equipment and Electrical and Electronics laboratory equipment.

Key Features

  • Working-cell demonstration: Helps students observe the practical operating principle of a primary electrochemical cell.
  • Electrochemistry teaching aid: Supports lessons on electrodes, electrolytes, oxidation-reduction reactions and current generation.
  • Energy-conversion learning: Demonstrates the conversion of stored chemical energy into electrical energy.
  • Hands-on laboratory use: Allows teachers to connect theoretical battery concepts with an observable apparatus.
  • Primary-cell study: Useful for comparing non-rechargeable primary cells with other electrochemical cell types.
  • Curriculum support: Suitable for supervised school, college and introductory laboratory practicals involving electricity and electrochemistry.

Technical Specifications

Specification

Detail

Product Name

Leclanche Cell Working Model

Brand

STEMAids

Product Type

Primary electrochemical cell demonstration apparatus

Scientific Principle

Conversion of chemical energy into electrical energy through electrochemical reactions

Cell Classification Demonstrated

Primary cell

What’s Included in the Kit

  • 1 × Leclanche Cell Working Model

Electrodes, electrolyte chemicals, porous pot, connecting leads and other accessories should be confirmed with STEMAids for the exact supplied configuration before publication or tender submission.

Applications / Uses

  • Demonstrating the working principle of a primary electrochemical cell.
  • Teaching chemical-to-electrical energy conversion.
  • Explaining anode, cathode, electrolyte and external-circuit concepts.
  • Supporting lessons on oxidation and reduction in electrochemical cells.
  • Comparing primary cells with rechargeable secondary cells.
  • Conducting supervised physics and introductory electrochemistry demonstrations.

How to Use the Leclanche Cell Working Model

  1. Place the apparatus on a stable, dry laboratory bench.
  2. Identify the principal cell components using the supplied product instructions.
  3. If assembly or chemical preparation is required, follow only the manufacturer’s supplied procedure.
  4. Connect a suitable measuring or demonstration circuit to the cell terminals with correct polarity.
  5. Observe the electrical response and relate it to the electrochemical reactions occurring within the cell.
  6. Disconnect the circuit after the demonstration and clean or store the apparatus according to the supplied instructions.

Safety note: If the supplied model uses chemical electrolyte or active electrode materials, teachers and laboratory staff should follow appropriate chemical-handling procedures, use suitable personal protective equipment and prevent skin or eye contact.

Care & Maintenance

  • Keep terminals and reusable apparatus components clean and dry after practical sessions.
  • Do not leave chemical residues in the apparatus unless the manufacturer specifically permits storage in an assembled condition.
  • Inspect electrodes, leads and containers for corrosion, leakage or damage before reuse.
  • Store chemicals separately and according to their applicable laboratory safety requirements.

Why Choose STEMAids

STEMAids develops and supplies educational science models, STEM kits and laboratory teaching apparatus for institutional learning environments. Its portfolio is designed for practical science instruction and hands-on classroom use. Buyers can review the broader STEMAids product catalogue and institutional procurement information through its tender and supply resources.

Frequently Asked Questions

What is a Leclanche Cell Working Model used for?

It is used to demonstrate how a primary electrochemical cell produces electrical energy through chemical reactions between its active components.

What type of cell is a Leclanché cell?

The Leclanché cell is a primary electrochemical cell. Primary cells are intended for discharge rather than routine electrical recharging.

What does the model teach students?

It helps students understand electrodes, electrolytes, redox reactions, polarity, current flow and the conversion of chemical energy into electrical energy.

Does a Leclanché cell use zinc and carbon?

A conventional Leclanché cell uses zinc and a carbon-based positive-electrode arrangement, with ammonium chloride serving as an electrolyte and manganese dioxide functioning as a depolarizing material. The exact components supplied with this STEMAids model should be confirmed separately.

Can the model be used in school laboratories?

Yes. It is suitable for supervised school and college demonstrations of primary cells, electricity and introductory electrochemistry.

What voltage does this model produce?

The exact rated output of this STEMAids working model has not been verified. It should be confirmed from the current product datasheet rather than inferred from generic Leclanché-cell values.

Bestsellers

Transistor V-I Characteristics Trainer

Original price was: ₹3,400.00.Current price is: ₹1,690.00.
(0 Reviews)

Socket Mounted Diode Characteristics Apparatus

Original price was: ₹3,400.00.Current price is: ₹1,690.00.
(0 Reviews)

Digital Logic Gate Experiment Kit

Original price was: ₹1,700.00.Current price is: ₹840.00.
(0 Reviews)

Step Down Transformer

Original price was: ₹620.00.Current price is: ₹300.00.
(0 Reviews)

Zener Diode Apparatus (Socket Type)

Original price was: ₹2,200.00.Current price is: ₹1,090.00.
(0 Reviews)

Ohm’s Law Experimental Kit with Integrated Power Supply

Original price was: ₹1,500.00.Current price is: ₹740.00.
(0 Reviews)

Back to Top
Select your currency
INR Indian rupee
Product has been added to your cart
Compare (0)