Search

In Stock

DUAL-SCALE AC AMMETER 3-10 AMPS

Dual-scale analog display supporting both low and mid-range AC measurement for instructional versatility

Panel-mount construction with calibrated movement ensuring stable readings under continuous lab use

$5.14

Quick Answer: The Dual-Scale AC Ammeter 3-10 Amps is an analogue meter for measuring alternating current, with two ranges, 3 A and 10 A, read from two scales on one dial. A dual-scale AC ammeter is connected in series with a load to measure the current in transformer, lamp and heating-effect experiments.

What an AC Ammeter Reads

An alternating current reverses direction many times each second, so a meter cannot simply follow it. AC ammeters are calibrated to show the root-mean-square (RMS) value: the steady direct current that would produce the same heating effect in a resistor. For a sinusoidal supply the peak current is about 1.41 times the RMS reading. This is the value used in power calculations, which is why it is the one marked on appliances.

Analogue school AC ammeters are commonly of the moving-iron type, in which the current in a fixed coil magnetises two soft-iron vanes that repel each other and turn the pointer. The force depends on the square of the current, so the reading does not depend on direction, and the scale is usually crowded at its low end. A moving-coil meter on its own cannot read AC at all, because the forces on its coil reverse every half cycle. The movement type of this ammeter should be confirmed when ordering.

Using the Two Ranges

Two ranges on one instrument let the same ammeter serve a small transformer secondary and a heavier load. Typically one terminal is common and the other two select the range, and each range has its own scale printed on the dial. Start on the 10 A range, note the reading, and move to the 3 A range only if the current is clearly below 3 A; the lower range spreads the same current over a larger part of the scale and gives a more precise reading.

Specifications

Quantity measured Alternating current (RMS)
Ranges 3 A and 10 A, as titled
Display Analogue dial with two scales
Connection In series with the load
Movement type, terminals and mounting Confirm at enquiry

Experiments

  • Measuring primary and secondary currents of a step-down transformer and comparing their ratio with the turns ratio
  • Comparing the AC current through a lamp with the DC current that gives the same brightness, to show what RMS means
  • Measuring the current drawn by heating elements and calculating power from current and voltage
  • Investigating how the current through a coil changes when an iron core is inserted

Care & Handling

  • Always connect the dual-scale AC ammeter in series with a load, never directly across a supply; its resistance is very low and it would short-circuit the source.
  • Use low-voltage AC from a suitable step-down supply for student work; mains wiring should only be handled by a qualified person.
  • Switch off before changing ranges or connections, and check the pointer reads zero before switching on.
  • Store the meter flat and away from strong magnets, and avoid knocks that can bend the pointer or pivot.

Why Choose LabEquip

Physics laboratories buy a few AC ammeters alongside their DC meters so that transformer and heating-effect practicals can run at several benches. LabEquip lists this ammeter in its physics lab equipment range; for direct-current circuits, the moving coil meters are the matching choice. Ask about movement type and terminals through our contact page.

Frequently Asked Questions

Why does the ammeter have two scales?

Each scale belongs to one range. The 10 A scale covers larger currents, and the 3 A scale spreads smaller currents across the whole dial so they can be read more precisely. Read the scale that matches the terminal in use.

What does an AC ammeter actually measure?

It shows the RMS current, the value of direct current that would give the same heating effect. For a normal sinusoidal supply the current actually swings between peaks about 1.41 times larger than the reading, in both directions.

Can the meter be used in a DC circuit?

A moving-iron meter does respond to direct current, but its calibration is set for AC and the reading may be less accurate. For DC practicals it is better to use a meter designed and calibrated for direct current.

Why is the scale crowded near zero?

In a moving-iron meter the turning force depends on the square of the current, so small currents produce very little deflection. The marks are therefore close together at the low end of the scale and spread out higher up.

Which range should be selected first?

The 10 A range. If the reading is well below 3 A, switch off, move the connection to the 3 A terminal and measure again. Starting on the higher range protects the meter from an unexpectedly large current.

How is an ammeter different from a voltmeter in a circuit?

An ammeter has a very low resistance and goes in series, so the current passes through it. A voltmeter has a high resistance and is connected in parallel across a component. Swapping them either reads nothing useful or overloads the ammeter.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
USD United States (US) dollar
Product has been added to your cart
Compare (0)