Quick Answer: The Digital Infrared Moisture System determines the moisture content of a sample by drying it under an infrared heater while weighing it, then calculating moisture from the mass lost. Instruments of this kind, often called infrared moisture balances, give a loss-on-drying result in minutes instead of the hours an oven method takes.

The Loss-on-Drying Principle

Moisture content by loss on drying is defined from two weighings: the initial mass of the sample and its mass after the water has been driven off. Moisture as a percentage of the wet mass is (initial − dry) ÷ initial × 100. A conventional drying oven gets there by heating samples for hours and weighing them separately; an infrared system combines the heater and the balance so the mass is followed continuously while the sample dries.

Infrared radiation from the heater is absorbed at and just below the sample surface, warming it quickly without first heating a large oven chamber. As water evaporates the mass falls, and drying is ended when the rate of loss drops below a set threshold or after a chosen time, depending on how the system is programmed. The display then shows the moisture percentage, and many systems can also report dry matter or the mass lost.

Specifications

Method Loss on drying with infrared heating
Principle Mass measured before and during drying; moisture calculated from mass lost
Output Moisture percentage on a digital display
Sample Thin, even layer on the sample pan
Heater type, temperature range and balance capacity Confirm at enquiry

Getting Repeatable Results

Sample preparation matters more than any setting. The material should be spread thinly and evenly on the pan so heat reaches all of it, and the same sample mass used each time; a thick heap dries on top while staying wet underneath. Too high a drying temperature can scorch organic samples or drive off other volatile substances, giving a falsely high reading, while too low a temperature leaves water behind. For a new material, results are compared with the reference oven method and the temperature and end point adjusted until the two agree.

Materials and Uses

  • Moisture in grain, flour, seeds and animal feed
  • Water content of soil samples in agriculture and environmental studies
  • Drying checks on plastics granules, powders and pharmaceutical ingredients
  • Teaching thermogravimetric analysis and the loss-on-drying method
  • Quality-control comparisons against the oven reference method

Care & Handling

  • Place the digital infrared moisture system on a firm, level bench away from draughts and vibration, which disturb the balance reading.
  • Let the heater and pan cool before removing samples; the pan and housing stay hot after a run.
  • Clean spilled powder from the balance area so it does not affect the zero or burn on the heater.
  • Check the balance with a reference mass periodically and follow the instrument’s calibration procedure.

Why Choose LabEquip

Food, agriculture, polymer and pharmacy laboratories buy infrared moisture systems where many samples must be tested each day, and colleges use one to teach the drying method. It is listed in LabEquip’s Physics Equipments; for quick field readings on grain, see the digital moisture meter for grain. Ask about heater type and capacity via the contact page.

Frequently Asked Questions

How does an infrared moisture system differ from a drying oven?

An oven heats many samples for a long time, and each is weighed before and after. The infrared system heats one sample directly and weighs it continuously, giving a result in minutes, but it tests one sample at a time and is usually set up to agree with the oven method.

Why do some samples read higher than their true water content?

If the temperature is too high, the sample can decompose or lose volatile substances such as oils, alcohol or flavour compounds. The balance cannot tell these from water, so the mass loss overstates moisture.

How much sample should be used?

Enough to cover the pan in a thin, even layer. The exact mass depends on the material and the balance, but using the same mass every time matters more than the precise amount for repeatable results.

What decides when drying is finished?

Usually an automatic end point, when the mass falls by less than a set amount over a set time, or a fixed drying time chosen during method development. Both should be validated against a reference method for each material.

Is moisture reported on a wet or dry basis?

Most systems report moisture as a percentage of the initial wet mass. Some can also show the dry-basis value, the water mass divided by the dry mass, which is the convention in soil science and timber work.

Can liquids be tested?

Liquids and pastes can be tested if they are spread on a glass-fibre pad or in a thin film so they dry evenly without boiling or spattering. Results should be checked against an established method for that product.