Search

In Stock

Demonstration Heat Pump

Pompe à chaleur de démonstration, Integrated Mass Flow Meter facilitates the Evaluation of refrigerant mass flow rates, enabling the precise determination of entropy production and system energy balance.

High-Sensitivity Thermocouple Array Supports the Application of energy conservation laws by providing real-time data for source/sink temperature differentials during steady-state operation.

Transparent Expansion Interface Provides visual Understanding of the isenthalpic expansion process and liquid-to-vapor phase transitions, bridging theoretical models with physical observation.

$210.37

Quick Answer: The demonstration heat pump is a teaching unit, usually built around an electric compressor and a sealed refrigerant circuit, that moves heat from a cold water reservoir to a warm one. Students measure the temperatures on each side and the electrical energy used, then calculate the coefficient of performance and follow the refrigerant cycle.

The Vapour-Compression Cycle

Inside the heat pump a refrigerant circulates in a closed loop. In the evaporator, placed in the cold reservoir, the low-pressure liquid refrigerant boils and absorbs latent heat, cooling the water around it. The compressor then raises the pressure and temperature of the vapour. In the condenser, placed in the warm reservoir, the hot vapour condenses and gives out its latent heat. Finally an expansion valve or capillary tube drops the pressure again and the cycle repeats.

Demonstration units often leave these parts in view, and where pressure gauges are fitted on the high and low sides students can relate each stage to the state of the refrigerant. The same circuit is found in a domestic refrigerator and in heat pumps that warm buildings; only the side that is put to use changes.

Specifications

Item Demonstration heat pump for teaching
Principle Vapour-compression cycle: evaporator, compressor, condenser and expansion device
Measurements Reservoir temperatures, electrical energy and coefficient of performance
Level Senior secondary, college and university thermodynamics
Refrigerant, gauges, power supply and reservoir size Confirm at enquiry

Measuring the Coefficient of Performance

With the reservoirs filled with known masses of water, the heat gained by the warm side over a set time is m c times the temperature rise. Dividing it by the electrical energy used by the compressor in the same time gives the heating coefficient of performance. As an illustrative example, if the warm reservoir gains 100 kJ while the compressor uses 40 kJ, the COP is 2.5. As the warm side heats and the cold side cools, the temperature lift grows and the COP of the demonstration heat pump falls, which students can show by repeating the calculation over successive intervals.

Applications

  • Measuring the coefficient of performance of a real heat pump
  • Following the refrigerant cycle stage by stage
  • Comparing heating and cooling performance from the same unit
  • Discussing heat pumps for building heating and energy efficiency

Care & Handling

  • Only trained staff should service the refrigerant circuit; never open or loosen its fittings
  • Keep the unit upright, and let it stand for a while before switching on after it has been moved
  • Keep water away from electrical parts when filling or emptying the reservoirs
  • Allow time between switching off and restarting, as compressors need the pressures to equalise

Why Choose LabEquip

Colleges and universities select the demonstration heat pump because students can measure a real COP with the same cycle used in refrigerators and building heat pumps. It pairs with the Peltier module heat pump for a comparison with solid-state cooling and sits within our physics lab equipment range; contact LabEquip for refrigerant and supply details.

Frequently Asked Questions

What is the coefficient of performance?

It is the useful heat moved divided by the work or electrical energy supplied. For heating, the heat delivered to the warm side is used, and for cooling, the heat removed from the cold side.

Why can a heat pump deliver more heat than the electricity it uses?

Most of the delivered heat is taken from the cold side; the electrical energy only drives the transfer. Energy is still conserved, since the heat delivered equals the heat absorbed plus the energy used.

Why does the COP fall during the experiment?

As the warm reservoir heats up and the cold one cools down, the compressor must lift heat across a larger temperature difference. More work is needed for each unit of heat moved, so the COP decreases.

Is the refrigerant dangerous?

In normal use it stays sealed inside the circuit. The circuit is under pressure, so it must never be opened by students, and any leak or repair should be handled by a qualified technician.

How is this different from a refrigerator?

It is the same cycle. A refrigerator is used for the cold it produces inside, while a heat pump for heating uses the warmth released at the condenser; the demonstration unit lets students measure both sides.

What is the highest COP possible?

The ideal limit for heating is Th divided by the difference Th minus Tc, with temperatures in kelvin. Real units achieve much less because of friction, heat losses and the irreversible expansion of the refrigerant.