Search

In Stock

CIRCULAR COIL

Uniformly Wound Conductive Coil: Ensures symmetrical magnetic field generation for precise experimental observation.

Rigid Insulated Frame Mounting: Maintains coil geometry and alignment during repeated current flow experiments.

₹775.00

Quick Answer: The Circular Coil is a coil of insulated wire wound in a circle, usually mounted upright on a base, used to study the magnetic field produced by a current flowing round a loop. With a compass or deflection magnetometer at its centre or along its axis, a circular coil lets students test how the field depends on current, radius and distance.

The Field at the Centre and Along the Axis

Every short piece of a current-carrying loop contributes a little magnetic field, and at the centre of a circle all those contributions point the same way, along the axis. For a coil of n turns and radius r carrying current I, the field at the centre is B = μ0nI/2r. Doubling the current doubles the field, while a larger coil gives a weaker field at its centre for the same current.

Moving away from the centre along the axis, the field falls off. At a distance x it is B = μ0nIr² / [2(r² + x²)^(3/2)], so a graph of field against distance is bell-shaped, with points of inflection at x = r/2 on either side of the coil. Far from the coil the field falls off like that of a short bar magnet, which is the link between current loops and magnetic dipoles.

The Usual Laboratory Arrangement

In the classic college experiment, sometimes called the Stewart and Gee arrangement, the coil stands in the magnetic meridian with a deflection magnetometer sliding on a bench through its centre, so that the compass needle lies on the axis. The coil’s field is then at right angles to the horizontal component of the Earth’s field, and the needle settles at an angle θ where B = BH tan θ. Readings are taken with the current in both directions and the deflections averaged, which cancels small errors from the needle not lying exactly at the zero mark.

Experiments

  • Measuring how the magnetic field varies along the coil’s axis and plotting the bell-shaped curve
  • Finding the horizontal component of the Earth’s magnetic field using the tangent law
  • Checking that the field at the centre is proportional to the current
  • Locating the points of inflection and comparing them with the r/2 prediction
  • Introducing the Biot–Savart law with a measurable example

Specifications

Apparatus Coil of insulated wire wound in a circle, on a stand
Principle Magnetic field of a current loop (Biot–Savart law)
Measured with Deflection magnetometer or compass on the coil axis
Supply Low-voltage DC through a rheostat, ammeter and reversing key
Number of turns, radius and tappings Confirm at enquiry

Care & Handling

  • Keep magnets, iron stands and steel tools well away from the circular coil and magnetometer during readings, as they distort the field.
  • Pass current only while reading, and switch off between settings so the winding does not warm up and change resistance.
  • Use a reversing key rather than unplugging leads to change the current direction.
  • Store the coil upright, protected from knocks that could loosen or deform the turns.

Why Choose LabEquip

Physics departments in colleges and senior secondary schools buy circular coils with matching magnetometers for the magnetism practical cycle. The coil appears in our Physics Equipments listing, and it pairs with the deflection magnetometer used to read the field. Send your batch size through the LabEquip contact page.

Frequently Asked Questions

Why must the coil be set in the magnetic meridian?

When the plane of the coil lies north–south, its axial field is at right angles to the Earth’s horizontal field. Only then does the tangent law, B = BH tan θ, apply directly to the needle’s deflection.

Why are readings taken on both sides of the coil?

The field should be symmetrical about the centre, so readings at equal distances east and west should match. Averaging both sides cancels errors from the scale or needle being slightly off-centre and checks the coil alignment.

Why is the current reversed for each reading?

Reversing the current reverses the deflection. Averaging the two deflections removes errors caused by the needle’s zero not lining up exactly with the scale and by any small stray field.

What are the points of inflection on the graph?

They are the two positions, one on each side of the coil at a distance of half its radius, where the field-distance curve is steepest and changes from curving one way to curving the other. Near them the field changes almost linearly with distance.

Can the coil be used as a tangent galvanometer?

Yes, in principle. With the magnetometer at the centre and the coil in the meridian, the current is proportional to tan θ, which is how a tangent galvanometer measures current. Coils sold specifically as tangent galvanometers usually have several tappings for different numbers of turns.

What current should be used?

Enough to give deflections roughly between 30 and 60 degrees near the centre, where tan θ changes steadily and reading errors are smallest. A rheostat in series sets the current, and the coil’s rating should be checked before using larger currents.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
INR Indian rupee
Product has been added to your cart
Compare (0)