Quick Answer: The Analytical Balance, Basic – 220g/320g – 0.1mg is an entry-level electronic analytical balance listed in 220 g and 320 g capacity versions, both reading to 0.1 mg. As a basic analytical balance it covers the core job of quantitative weighing in teaching, pharmacy and quality-control laboratories.
Choosing Between 220 g and 320 g
Both versions read to the fourth decimal place of a gram; the difference is how much load the pan will take. Capacity matters more than it first seems, because the container counts towards it. A small volumetric flask or a porcelain crucible with its lid can use up a large share of 220 g before any sample goes in, and weighing into heavy vessels is where the 320 g version gives useful headroom. For work in light weighing boats and small bottles, 220 g is ample.
Running any balance close to its maximum also leaves little margin against an accidental overload, so the larger capacity is the sensible choice where heavy vessels are routine.
Applications
- Routine quantitative weighing in college chemistry practicals
- Weighing into heavier vessels such as lidded crucibles and small volumetric flasks (320 g version)
- Preparing buffer and standard solutions in pharmacy and quality-control laboratories
- Finding water of crystallisation or loss on ignition by weighing before and after heating
What the Basic Model Is For
Basic marks this as the entry model of the range. Basic analytical balances are generally aimed at routine weighing, taring and calibration, while features such as a touch-screen interface and extended application modes belong to higher models such as the touch screen analytical balance. For a teaching laboratory where students mainly weigh, tare and write down results, the simpler operation is an advantage.
Care & Handling
- Check the level indicator each morning; a basic analytical balance that is not level gives readings that change with where the load sits on the pan.
- Keep the weighing chamber clean with a soft brush; dried salt crystals on the pan or chamber floor add to readings and corrode metal parts.
- Do not lean on the bench or work beside the balance while the final reading is taken; vibration shows in the last digit.
- Leave the balance in standby rather than switched off overnight if the manual recommends it, so it stays at working temperature.
Specifications
| Type | Electronic analytical balance, basic model |
| Capacity | 220 g or 320 g version |
| Readability | 0.1 mg (both versions) |
| Typical users | Teaching, pharmacy and quality-control laboratories |
| Interfaces, calibration type and pan size | Confirm at enquiry |
Why Choose LabEquip
This basic model suits departments that need several analytical balances for student practicals and want simple operation. LabEquip lists it in its physics equipment category, alongside the standard 220 g analytical balance. Tell us which capacity you need and how many through the contact page.
Frequently Asked Questions
Does the container count towards the capacity?
Yes. Taring sets the display to zero, but the balance still carries the container, so container plus sample must stay under the maximum capacity. This is the main reason to choose the 320 g version for work in heavy vessels.
How do I take a substance to constant mass?
Heat it, cool it in a desiccator and weigh it; then repeat the heating, cooling and weighing until two successive readings agree within the limit your method sets, often a few tenths of a milligram. Only then has all the water or volatile matter been driven off.
Why does levelling matter on an analytical balance?
If the balance is tilted, the load does not press straight down on the weighing cell, and readings change slightly depending on where the object sits on the pan. Adjust the feet until the level indicator is centred, and recheck after moving the balance.
How is water of crystallisation found by weighing?
Weigh hydrated copper(II) sulfate in a crucible, heat it gently until the blue crystals turn white and stop losing mass, and weigh again. The loss in mass is the water, from which the number of water molecules per formula unit is calculated.
How should spilled chemicals be removed from the weighing chamber?
Set the balance to standby, lift out the pan if the manual allows, and brush out dry powder with a soft brush. Wipe any residue with a cloth barely damp with water or mild detergent, then dry. Never let liquid run down into the weighing mechanism.
Is a basic model good enough for pharmacy practicals?
Its readability is the same 0.1 mg as higher analytical models, so for routine weighing of samples, standards and excipients it is suitable. Compare repeatability figures in the data sheets if your methods set a minimum sample weight.
Last Updated: October 2026