Search

In Stock

Weight Set, 1mg-200g, Class F2

Austenitic Stainless Steel Construction: Forged with high-density, non-magnetic alloys featuring low magnetic susceptibility to prevent electromagnetic interference during sensitive mass determination workflows.

Integrated Adjustment Cavity Design: Features precision-machined internal chambers that allow for exact mass regulation, paired with a high-gloss polished finish to minimize surface porosity and particulate accumulation.

₹1,690.00

Quick Answer: The Weight Set, 1mg-200g, Class F2 is a set of test weights from 1 mg to 200 g, titled in accuracy class F2, used for routine checks of top-pan and precision balances. Class F2 test weights reaching down to milligrams suit school and college laboratories, small workshops and counters that weigh small, valuable quantities.

Seeing Weighing Errors in Class

A set of known weights is the clearest way to show students that a balance reading is not automatically the truth. With an F2 set and a school top-pan balance, a class can measure the error at several loads by subtracting each weight’s nominal value from the reading, express it as a percentage and compare it with the balance’s stated readability. Students then change one condition at a time: open a window to create a draught, stand a warm beaker of water beside the pan, or rub the plastic draught shield to charge it. Each produces a visible change in the reading.

The exercise turns abstract sources of error into things students can see and fix, and it shows why laboratories check their balances with known weights before trusting the results.

Where an F2 Set Fits

In the classification of weights, F2 is the lower of the two F classes, intended for checking balances of the high accuracy class and for calibrating M-class weights. A set that reaches down to 1 mg extends those checks to small loads, which helps on balances used for small samples of chemicals, medicines or precious metals. For analytical balances whose readability is finer than F2 errors allow, a higher class is needed.

Applications

  • Routine checks of top-pan and precision balances
  • Student practicals measuring balance errors and their causes
  • Checking counter balances that weigh small quantities of valuable materials
  • Calibrating M-class weights by comparison

Specifications

Nominal range 1 mg to 200 g, as titled
Accuracy class F2, as titled
Role Working test weights for balance checks
Small pieces Milligram weights handled with forceps
Piece list, material, case and documentation Confirm at enquiry

Care & Handling

  • Handle the Class F2 test weights with gloves or forceps and keep the milligram pieces in their compartments.
  • Before each check, level and zero the balance and close any draught shield.
  • Keep the set away from chemicals and damp, and wipe pieces only with a soft, dry cloth.
  • Keep the set separate from general class weights so it is used only for checks.

Why Choose LabEquip

Schools, colleges and small businesses that rely on top-pan balances buy F2 sets to keep those balances honest at a sensible cost. LabEquip lists this set in its Physics Equipments range; the Class F2 weight set, 1 g to 2 kg covers heavier loads. Send your requirements through the contact page.

Frequently Asked Questions

How do students measure the error of a balance?

Place a known weight on the pan, read the balance and subtract the nominal value. Repeating at several loads and expressing each error as a percentage of the load shows how the error behaves across the range.

Why does a warm beaker near the balance change the reading?

Warm air rising beside or under the pan creates currents that push on it, so the balance can read lighter or heavier until temperatures even out. Samples and weights should always be at room temperature.

Can static electricity affect a balance?

Yes. A charged plastic container or draught shield exerts small electrical forces on the pan or sample, causing drifting readings. Metal containers, not rubbing plastic surfaces and normal room humidity all reduce the effect.

Is an F2 set suitable for checking jewellery or pharmacy scales?

F2 weights are commonly used to check balances of the high accuracy class that weigh precious metals or medicines. Where weighing is for trade, local legal-metrology rules decide which weights must be used for official verification.

Why include milligram pieces in an F2 set?

They let the balance be checked at very small loads, which matters when small samples are weighed. An error that looks tiny at a large load can be a large percentage of a small sample.

What is the difference between F2 and F1 weights?

F1 is one class higher, with permissible errors about one third of F2 values for the same nominal mass. F1 is chosen for more demanding balance checks, F2 for routine checks where its errors are negligible compared with the balance tolerance.

Last Updated: October 2026

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
INR Indian rupee
Product has been added to your cart
Compare (0)