Search

In Stock

Wireless key MTICWD-200 Guardian 7000

$76.70

The StemAids Wireless Key MTICWD-200 for Guardian 7000 is a wireless dongle accessory used to enable SmartLink connectivity on compatible Guardian 7000 hotplate stirrer systems. It supports Bluetooth-based safety communication between the hotplate stirrer and a paired smart device, helping laboratories improve supervised heating operation and reduce the risk of unattended heating.

Product Description

The StemAids Wireless Key MTICWD-200 is designed for laboratories using Guardian 7000 hotplate stirrers where wireless safety monitoring and SmartLink functionality are required. When paired with a compatible smart device, the wireless key helps the system detect connection loss and supports automatic heater shut-off functionality for safer laboratory operation.

This accessory is especially useful in chemistry, pharmaceutical, research, academic, quality-control, and industrial laboratories where heating applications require additional safety support. It is suitable for users who want to enhance hotplate stirrer safety, improve monitoring discipline, and support modern laboratory workflow control.

Key Features

  • Wireless dongle accessory for compatible Guardian 7000 hotplate stirrers
  • Required accessory for enabling SmartLink functionality
  • Bluetooth-based wireless communication support
  • Pairs with a compatible smart device for safety monitoring
  • Helps support automatic heater shut-off if the wireless link is lost
  • Useful for reducing unattended heating risks in laboratory environments
  • Compact accessory suitable for professional, research, and educational laboratories
  • Procurement-friendly accessory for Guardian 7000 hotplate stirrer users

Product Specifications

Product Name StemAids Wireless Key MTICWD-200 for Guardian 7000
Brand StemAids
Product Type Wireless Dongle / Wireless Key / SmartLink Accessory
Reference Model MTICWD-200
Reference Item Number 30412537
Connectivity Bluetooth wireless connectivity
Compatible Equipment Compatible Guardian 7000 hotplate stirrer systems
Supported Function SmartLink safety communication and wireless monitoring support
Main Safety Function Supports heater shut-off when the Bluetooth link is broken, subject to compatible system settings
Recommended Use Supervised heating, stirring, sample preparation, chemical heating, and laboratory safety monitoring
Suitable Users Schools, colleges, universities, R&D laboratories, pharmaceutical labs, QC labs, and industrial testing laboratories
Installation Note Install and pair only as per the Guardian 7000 operating manual and compatible SmartLink instructions

Compatible Guardian 7000 Models

Guardian 7000 Model Accessory Compatibility Use Case
e-G71HS07C Wireless Dongle MTICWD-200 supported 7 x 7 inch ceramic top hotplate stirrer safety monitoring
e-G71HS10C Wireless Dongle MTICWD-200 supported 10 x 10 inch ceramic top hotplate stirrer safety monitoring
e-G71HSRDM Wireless Dongle MTICWD-200 supported Round aluminium top hotplate stirrer safety monitoring

How to Use StemAids Wireless Key MTICWD-200

  1. Confirm that your Guardian 7000 hotplate stirrer supports the MTICWD-200 wireless key.
  2. Switch off the hotplate stirrer before installing the wireless dongle.
  3. Insert the wireless key into the designated compatible communication port as per the equipment manual.
  4. Switch on the Guardian 7000 hotplate stirrer.
  5. Open the compatible SmartLink or supported smart-device connection function.
  6. Pair the smart device with the MTICWD-200 wireless key using the recommended Bluetooth procedure.
  7. Confirm that the wireless connection is active before starting heating operation.
  8. Set the required temperature, stirring speed, and timer according to the laboratory method.
  9. Keep the paired smart device within the recommended connection range during operation.
  10. After use, switch off the hotplate stirrer and store the wireless key safely if it is removed from the instrument.

Applications

  • Wireless safety monitoring of Guardian 7000 hotplate stirrers
  • SmartLink-enabled supervised heating workflows
  • Chemical sample heating and stirring applications
  • Research and development laboratory heating procedures
  • Pharmaceutical and quality-control laboratory work
  • Educational laboratory demonstrations requiring improved safety control
  • Laboratory environments where unattended heating risk must be reduced

Why Choose StemAids?

StemAids supplies practical laboratory accessories for educational, research, and industrial users who require dependable compatibility, clear procurement details, and safety-focused laboratory operation. The StemAids Wireless Key MTICWD-200 for Guardian 7000 is suitable for laboratories that need SmartLink wireless functionality for compatible Guardian 7000 hotplate stirrer systems.

  • Suitable for institutional laboratory purchase and replacement needs
  • Supports safety-focused hotplate stirrer workflows
  • Useful for laboratories handling heating and stirring applications
  • Clear model and item-number details for quotation and tender documentation
  • Appropriate for academic, research, QC, and industrial laboratory environments

Care and Safety Instructions

  • Use only with compatible Guardian 7000 hotplate stirrer models.
  • Do not use the wireless key if it is physically damaged.
  • Keep the dongle away from liquid spills, corrosive vapours, and direct heat exposure.
  • Do not remove the dongle while the instrument is actively heating unless instructed by the equipment manual.
  • Always confirm wireless connection status before starting heating operation.
  • Do not depend only on wireless monitoring; laboratory heating must remain supervised by trained personnel.
  • Store the wireless key in a clean, dry, and protected location when not in use.
  • Follow all safety instructions provided with the Guardian 7000 hotplate stirrer system.

SEO Keywords

Wireless Key MTICWD-200 Guardian 7000, StemAids MTICWD-200 wireless key, Guardian 7000 wireless dongle, SmartLink wireless dongle, hotplate stirrer wireless key, laboratory wireless dongle, Bluetooth dongle for hotplate stirrer, Guardian 7000 SmartLink accessory, MTICWD-200 dongle, 30412537 wireless dongle, hotplate stirrer safety accessory.

Frequently Asked Questions

What is the StemAids Wireless Key MTICWD-200 used for?

It is used as a wireless dongle accessory to enable SmartLink connectivity on compatible Guardian 7000 hotplate stirrer systems.

What is SmartLink functionality?

SmartLink is a safety-support function that uses a Bluetooth connection. If the wireless link is broken, the system can shut off heating on compatible Guardian 7000 hotplate stirrers.

Is the MTICWD-200 required for SmartLink?

Yes, the wireless dongle accessory is required to enable the SmartLink feature on compatible Guardian 7000 hotplate stirrer systems.

Which Guardian 7000 models can use this wireless key?

It is listed for Guardian 7000 models including e-G71HS07C, e-G71HS10C, and e-G71HSRDM.

Does the wireless key use Bluetooth?

Yes, it supports Bluetooth-based communication between the compatible hotplate stirrer and a paired smart device.

Can this accessory fully replace manual supervision?

No. It supports safer operation, but laboratory heating must still be monitored by trained personnel according to lab safety rules.

Can it be used in school or college laboratories?

Yes, it can be used in educational laboratories with compatible Guardian 7000 equipment and trained supervision.

What should be checked before ordering?

Confirm the hotplate stirrer model, SmartLink requirement, item number 30412537, and compatibility with your Guardian 7000 system before placing an order.

Reviews

There are no reviews yet.

Write a review

Back to Top
Select your currency
USD United States (US) dollar
Product has been added to your cart
Compare (0)