Stage Micrometer

High-Resolution Graduations: Features a 1mm linear scale meticulously laser-etched into optical glass, providing 100 equal divisions with a certified resolution of 0.01mm (10 microns) per interval.

Standardized Form Factor: Constructed on a 75mm x 25mm slide with a permanent cover glass, ensuring universal compatibility with mechanical stages and high-magnification oil immersion objectives.

₹540.00

Quick Answer: The Stage Micrometer is a microscope slide carrying a finely ruled scale of accurately known length, placed on the stage to calibrate an ocular micrometer (eyepiece graticule) and to measure the size of the field of view at each magnification.

The Reference Scale on the Stage

Measurements under a microscope depend on knowing how much of the specimen each eyepiece division covers, and this slide supplies the reference. Its scale, ruled or photo-etched on glass and usually protected by a cover glass, has divisions of known size marked in micrometres or millimetres, and it is focused exactly as a specimen would be.

A widely used pattern divides 1 mm into 100 parts of 0.01 mm, or 10 µm, each, but other scales exist, so read the values marked on the slide before use. Once the scale is in focus, it is compared with the ocular micrometer in the eyepiece to find the value of one eyepiece division for that objective.

The reference slide is used only for calibration: once the values for each objective are recorded, it is put away and the specimen slide takes its place. On its own it also measures the diameter of the field of view, which students need when estimating cell sizes by comparison with the field.

Calibration Tasks

  • Calibrating eyepiece graticules for each objective before cell measurements.
  • Measuring the field-of-view diameter at low, medium and high power.
  • Checking the magnification of a set-up after changing eyepieces or adding a camera.
  • Setting the scale in measurement software on microscope cameras.

Care & Handling

  • Focus with the low-power objective first and bring higher objectives in carefully, so no objective touches the slide.
  • Clean it only with a blower and lens tissue; the ruled area is easily damaged.
  • Keep the slide in its case, labelled with the scale value.
  • Record calibration values for each microscope and objective, so the slide is not needed every lesson.

Specifications

Form Glass microscope slide with an engraved or etched scale
Scale Divisions of known length, marked on the slide
Use Calibrating an eyepiece graticule; measuring the field of view
Used with Ocular micrometer and each objective in turn
Scale length and division value Confirm at enquiry

Why Choose LabEquip

School and college biology departments that teach cell measurement, and research or QC labs that measure particles or fibres, buy a stage micrometer to go with their eyepiece graticules. One slide can calibrate every microscope in a room, so most labs need only one or two. LabEquip lists it in General Lab Products alongside student microscopes, and orders can be placed through the contact page.

Frequently Asked Questions

What is a stage micrometer used for?

It is used to calibrate an eyepiece graticule, so that eyepiece divisions can be converted into real lengths, and to measure the diameter of the field of view. It is not used for routine measurement of specimens itself.

How do I find the value of one eyepiece division?

Line the eyepiece scale up with the stage scale, find two points where lines on both scales coincide and count the divisions on each between them. The stage length between those points divided by the number of eyepiece divisions gives the value of one division.

What scale does the slide carry?

It varies. A common pattern divides 1 mm into 100 divisions of 10 µm each, but 2 mm, 5 mm and 10 mm scales and other divisions also exist. Always use the values marked on the slide.

Can I use it with a microscope camera?

Yes. Photograph the stage scale at each magnification and use the image to set the calibration in the imaging software. Measurements made on later images are then in real units for that objective and camera setting.

Why does my calibration differ between objectives?

Each objective magnifies differently, so the same eyepiece division spans a different real length with each one. A higher-power objective gives a smaller value per division, which is why every objective needs its own calibration.

How should the slide be stored?

In its case, flat and away from heavy items, with the scale kept clean. The ruling is fine and cannot be repaired, so handle the slide by its edges and never clean it with anything abrasive.

Last Updated: September 2026