Search

In Stock

Mini Electrolysis Device

$14.10

Quick Answer: The mini electrolysis device is a compact kit for electrolysing water on a student bench. The listing photo shows a small clear rectangular tank, an electrode block holding two small inverted collecting tubes, and red and blue leads with crocodile clips for connection to a low-voltage supply.

Electrolysis Scaled Down for Student Benches

A Hofmann voltameter is usually a teacher’s piece: tall, glass and clamped to a stand. The mini electrolysis device brings the same experiment down to a size each group can handle. In the photo a dark electrode block sits on the floor of a clear rectangular tank, two small tubes stand upright on it, one over each electrode, and a yellow clip on the tank wall anchors the red and blue leads.

Students fill the tank with dilute electrolyte, fill the two tubes and invert them over the electrodes, then connect the leads to a low-voltage DC source. Bubbles stream from both electrodes into the tubes, and the tube over the negative electrode fills with hydrogen about twice as fast as the other fills with oxygen. No power source appears in the photo, so plan for a battery pack or a laboratory power supply.

Compared with the Hofmann voltameter, the small tubes hold less gas and give a less precise volume comparison, so this device suits observation and gas testing more than measurement. For a jar-based demonstration with larger collecting tubes, see the Brownlee electrolysis apparatus.

Applications

  • Small-group practicals on the electrolysis of water with dilute sodium sulfate solution
  • Observing which electrode produces more gas and relating it to the formula of water
  • Collecting a small tube of hydrogen for the lighted-splint pop test
  • Showing how the supply voltage affects the rate of bubbling

Specifications

Item Compact water electrolysis device
Tank Small clear rectangular tank (photo)
Electrodes Two electrodes in a block, each under a small collecting tube (photo)
Connections Red and blue leads with crocodile clips (photo)
Power source Not shown in the photo; a low-voltage DC supply is needed

Care & Handling

  • Connect the mini electrolysis device’s leads before switching the low-voltage supply on, and switch off before disconnecting.
  • Wear eye protection when handling the electrolyte and emptying the tank.
  • Rinse the tank, tubes and electrode block with water after each class and dry them before storage.
  • Clean the clear parts with water and mild detergent only, since solvents can craze clear plastics.

Why Choose LabEquip

Teachers who want every group to run its own electrolysis, rather than watch a single demonstration, buy several mini devices as a class set. LabEquip lists them in its chemistry lab equipment range, and class-set numbers can be arranged through the contact page.

Related Products

Frequently Asked Questions

Does the mini electrolysis device come with a power supply?

No power source is shown with the mini electrolysis device. Its red and blue leads with crocodile clips connect to a separate low-voltage DC supply, such as a school power pack or a battery, so it can be set up wherever such a supply is available.

Which tube collects hydrogen and which collects oxygen?

Hydrogen forms at the cathode, the electrode connected to the negative terminal, and oxygen at the anode, connected to the positive terminal. On the mini device, follow the blue and red leads back to the supply to see which tube sits over which electrode, then compare the gas volumes.

Why is the volume of hydrogen about twice the volume of oxygen?

Water is H2O, so splitting it gives two molecules of hydrogen for every molecule of oxygen. Equal volumes of gases at the same temperature and pressure hold equal numbers of molecules, so the hydrogen tube fills about twice as fast. Oxygen dissolves a little more readily, which can make the ratio slightly above two.

Why is sodium sulfate added to the water before electrolysis?

Pure water conducts electricity very poorly, so almost no current flows. A little sodium sulfate provides ions to carry the current without its own ions being discharged, leaving hydrogen and oxygen as the products. Dilute sulfuric acid is used for the same reason in some schools.

Can salt water be used in the mini electrolysis device?

It is better avoided. With sodium chloride, chlorine can form at the anode instead of oxygen, which is toxic, corrosive to electrodes and spoils the two-to-one comparison. Use the electrolyte recommended for water electrolysis, such as dilute sodium sulfate.

How is the mini device different from a Hofmann voltameter?

A Hofmann voltameter is a tall glass apparatus with graduated tubes and taps, usually a teacher demonstration. The mini electrolysis device is a small tank with two short collecting tubes over the electrodes, so each group can run the experiment at the bench and see both gases forming.

Last Updated: November 2026

Reviews

There are no reviews yet.

Write a review

Back to Top