Search

In Stock

Scintillation Vial

Ultra-Pure HDPE Formulation: Manufactured from high-density polyethylene with specialized additives to ensure exceptionally low background counts and minimal UV-quenching, maximizing the recovery of low-energy beta emitters.

Liner-less Hermetic Seal: Features a precision-engineered screw-cap closure with an integrated sealing ring, providing high chemical resistance to aggressive scintillation cocktails and ensuring zero evaporative loss during extended counting cycles.

$1.64

Quick Answer: A scintillation vial is a small screw-capped vial that holds a sample mixed with liquid scintillation cocktail so a liquid scintillation counter can measure its beta radioactivity. Outside radiochemistry, the same vials are widely used for storing small samples and standards.

Glass or Plastic Vials

In liquid scintillation counting, beta particles from the sample excite solvent and fluor molecules in the cocktail, which emit flashes of light picked up by photomultiplier tubes in the counter. The vial therefore has to be transparent to that light, resistant to the cocktail and uniform in shape, so every vial sits in the detector the same way.

Glass vials resist solvent-based cocktails and do not let solvent diffuse through the wall, but ordinary glass contains traces of potassium-40, which adds background counts; low-potassium glass reduces this. Plastic vials, usually polyethylene, give a lower background and do not break, but some cocktail solvents slowly permeate them.

The cap matters too: a foil or plastic liner helps stop solvent loss and keeps cocktail from creeping up the threads. Clean vials are also a handy size for storing soil and plant extracts, buffers, powders and reference samples, provided they are relabelled clearly and never mixed with vials from radioactive work.

Specifications

Use Liquid scintillation counting; small-sample storage
Closure Screw cap (liner type depends on version)
Glass vials (general) Resist solvents; slight potassium-40 background
Plastic vials (general) Low background; some solvents permeate the wall

Applications

  • Counting tritium or carbon-14 labelled samples from uptake or metabolism experiments
  • Measuring phosphorus-32 or sulfur-35 in molecular biology and biochemistry work
  • Holding filter discs or tissue digests in cocktail for counting
  • Storing small quantities of non-radioactive samples and reagents

Care & Handling

  • Add the cocktail volume your counter’s protocol specifies and cap tightly before shaking.
  • Wipe the outside of each vial before loading, since fingerprints and cocktail on the wall affect counts.
  • Let vials stand in the dark before counting if the protocol calls for it, to reduce light-induced background.
  • Dispose of used vials and cocktail by the route approved for radioactive and solvent waste.

Why Choose LabEquip

Radiochemistry, pharmacology and plant physiology labs, and teaching labs with a counter, use these vials in quantity. LabEquip supplies them in the Biology Lab Products range, with a scintillation vial rack for bench preparation; state glass or plastic on the contact page.

Related Products

  • Racks For Scintillation Vial: A bench rack that holds scintillation vials upright while cocktail is added and caps are labelled.
  • Ria Vial: An RIA vial, the small plastic tube used when gamma emitters are counted instead of beta emitters.
  • Storage Vial: A small screw-capped plastic vial for aliquots and stock solutions when solvent resistance is not needed.
  • Screw Cap Vials: Glass screw cap vials for storing and transporting small liquid or solid samples.

Frequently Asked Questions

What is a scintillation vial used for?

A scintillation vial holds a sample mixed with liquid scintillation cocktail so that a liquid scintillation counter can measure its beta radioactivity, for example from tritium or carbon-14. Away from radiochemistry, the same screw-capped vials are widely used to store small samples, standards and solvents.

Should I choose glass or plastic scintillation vials?

Glass vials resist almost every solvent and suit long storage, but the glass contains a little potassium-40, which adds a slight background count. Plastic vials give a lower background and do not shatter, but some solvents in older toluene or xylene cocktails can seep into or through the wall. Match the vial to the cocktail and the counting precision needed.

What is liquid scintillation cocktail?

Cocktail is a solvent containing fluors, compounds that give off a flash of light when energy from a beta particle passes to them. Modern cocktails also contain emulsifiers so that water-based samples mix in evenly. The counter’s photomultiplier tubes detect the flashes and count them.

Why must a scintillation vial be clean and free of scratches?

The counter reads light that passes out through the vial wall, so fingerprints, scratches, condensation or labels on the sides can absorb or scatter it and lower the count. Handle vials by the cap, write labels on the cap rather than the side, and wipe the outside before loading the counter.

Can scintillation vials be used for samples that are not radioactive?

Yes. Their size, screw cap and solvent resistance make them handy general sample vials for seeds, soil, small specimens, reference solutions and chemical samples in teaching and research labs. Keep any vials used for radioactive work separate and clearly marked.

How are used scintillation vials disposed of?

Vials with radioactive samples go into the lab’s radioactive waste stream under local radiation rules. The cocktail inside is also a chemical waste, and solvent-based cocktails are flammable, so full vials are not emptied down the sink. Vials used only for harmless samples can be washed and reused or discarded with normal lab waste.

Last Updated: November 2026